NULL_0000b	DATA_SET_ID = "EAR-C-COMPIL-5-DB-COMET-POLARIMETRY-V1.0"

0.	Same general comments from NULL_0000a apply to this volume.
	Such as, reference.cat file in catalog/targets directory that
	really isn't a reference catalog file and dataset.html file
	in the root directory doesn't have a pds label.

1.	root directory

	A.	voldesc.cat

		1.	Delete comment after PUBLICATION_DATE, not needed
			and makes ingestion fail

		2.	Filenames in CATALOG object do not match what is on
			the volume

	B.	aareadme.txt

		1.	Kinda sparce.  This file should be a general 
			description of what is on the volume.

		2.	File is missing required (recommended) sections.

		3.	Some directories missnamed, (e.g., sample/data)

		4.	Some directories listed, but not on volume, (i.e.,
			/DOCUMENT/CALIB_DOCS/*/, /DOCUMENT/COMET_POS/)
			

	C.	dataset.html

		1.	delete this file from the final archive

2.	catalog sub-directory

	A.	dataset.cat

		1.	Delete comment after DATA_SET_RELEASE_DATE, not
			needed and makes ingestion fail.

	B.	catalog/targets directory

		1.	reference.cat

			a.	Rename file (as discussed previously)

			b.	Ingestion failed due to missing TARGET_NAME
				keyword, however, this keyword is in your
				file.  Need to investigate more as to why
				ingestion fails.

3.	data sub-directory

	A.	dbcp_ref.lbl/dbcp_ref.tab

		1.	Do you want the information in this table to be in
			the PDS reference lookup database?  If so, we need
			to reformat it into a REFERENCE.CAT file.

4.	document sub-directory

	A.	no comments

5.	index sub-directory

	A.	no comments

==================
"NULL_0000a" is EAR-C-COMPIL-5-COMET-NUC-PROPERTIES-V1.0 - AR.