PDS_VERSION_ID = PDS3 RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 2880 FILE_RECORDS = 243 ^HEADER = "LOR_0003106166_0X634_SCI_1.FIT" ^IMAGE = ("LOR_0003106166_0X634_SCI_1.FIT", 12) ^EXTENSION_CALIB_ERROR_EST_HEADER = ("LOR_0003106166_0X634_SCI_1.FIT", 104) ^EXTENSION_CALIB_ERROR_EST_IMAGE = ("LOR_0003106166_0X634_SCI_1.FIT", 105) ^EXTENSION_CALIB_QUALITY_HEADER = ("LOR_0003106166_0X634_SCI_1.FIT", 197) ^EXTENSION_CALIB_QUALITY_IMAGE = ("LOR_0003106166_0X634_SCI_1.FIT", 198) NOTE = " - Earth Mean Equator and Vernal Equinox of J2000 is the inertial reference frame used to specify observational geometry. Geometric parameters are based on best available data at time of product creation. Refer to the SPICE archive for the most current observational geometry data. - All positions are relative to body centers - Target wrt S/C: X/Y/Z & Range - Light time corrected for light originating from UNK and received by S/C at observation midpoint. - Sun wrt Target - Light time corrected for light originating from Sun, reflected off of UNK, and received by S/C at observation midpoint - Sun wrt S/C - Light time corrected for light originating from Sun and received by S/C at observation midpoint - Earth wrt S/C - Light time corrected for light originating from Earth and received by S/C at observation midpoint - Solar phase angle (relative to inverted boresight) " MISSION_NAME = "NEW HORIZONS" DATA_SET_ID = "NH-X-LORRI-3-LAUNCH-V1.0" PRODUCT_ID = "LOR_0003106166_0X634_SCI_1" PRODUCER_INSTITUTION_NAME = "SOUTHWEST RESEARCH INSTITUTE" PRODUCT_TYPE = "EDR" SOFTWARE_NAME = "TOPDS 1.0" MISSION_PHASE_NAME = "POST-LAUNCH CHECKOUT" SEQUENCE_ID = "UNK" TARGET_NAME = "CALIBRATION" PRODUCT_CREATION_TIME = 2007-12-06T04:26:48 START_TIME = 2006-02-24T16:57:28.296 STOP_TIME = 2006-02-24T16:57:28.306 SPACECRAFT_CLOCK_CNT_PARTITION = 1 SPACECRAFT_CLOCK_START_COUNT = "0003106165:48500" SPACECRAFT_CLOCK_STOP_COUNT = "0003106165:49000" INSTRUMENT_NAME="LONG RANGE RECONNAISSANCE IMAGER" INSTRUMENT_HOST_NAME = "NEW HORIZONS" INSTRUMENT_ID = "LORRI" TELEMETRY_APPLICATION_ID = "0x634" EXPOSURE_DURATION = 0.010 FILTER_NAME = "N/A" DETECTOR_ID = "LORRI" DETECTOR_TYPE = "CCD" INST_CMPRS_TYPE = "NOTCOMP" SC_TARGET_POSITION_VECTOR = ( "N/A" , "N/A" , "N/A" ) TARGET_CENTER_DISTANCE = "N/A" TARGET_SUN_POSITION_VECTOR = ( "N/A" , "N/A" , "N/A" ) SOLAR_DISTANCE = "N/A" SC_SUN_POSITION_VECTOR = ( 168593264.8877716 , -39132839.3299978 , -19026572.8679652 ) SPACECRAFT_SOLAR_DISTANCE = 174118001.8109722 SC_EARTH_POSITION_VECTOR = ( 33473279.8983245 , 16427097.7839321 , 5061360.4463280 ) SC_GEOCENTRIC_DISTANCE = 37628810.4824229 PHASE_ANGLE = 105.70374 QUATERNION = ( 0.1871862404 , -0.1731217111 , 0.8068528173 , -0.5328965338 ) QUATERNION_DESC = "QUAT_AXYZ_J2K_TO_INSTR.ASC" OBJECT = HEADER BYTES = 31680 HEADER_TYPE = "FITS" INTERCHANGE_FORMAT = "BINARY" RECORDS = 11 DESCRIPTION = " FITS format defined in NASA/Science Office Standards Technology 100-1.0 " END_OBJECT = HEADER OBJECT = IMAGE DESCRIPTION = " FITS PDU PDU Calibrated data image - Corrections applied: - Bias subtraction - Smear removal - Flatfield correction - Absolute calibration - Corrections omitted: - Image subtraction - Signal linearization - CTI correction - Dark subtraction - Geometric correction - Geometric correction See the data set documentation, specifically the SOC Instrument Interface Control Document (ICD), for more details. " SAMPLE_BITS = 32 SAMPLE_TYPE = "IEEE_REAL" AXIS_ORDER_TYPE = "FIRST_INDEX_FASTEST" LINE_DISPLAY_DIRECTION = "UP" SAMPLE_DISPLAY_DIRECTION = "RIGHT" LINE_SAMPLES = 256 LINES = 256 END_OBJECT = IMAGE OBJECT = EXTENSION_CALIB_ERROR_EST_HEADER BYTES = 2880 HEADER_TYPE = "FITS" INTERCHANGE_FORMAT = "BINARY" RECORDS = 1 DESCRIPTION = " This is the FITS header for FITS EDU number: 1 FITS EDU name: LORRI Error image " END_OBJECT = EXTENSION_CALIB_ERROR_EST_HEADER OBJECT = EXTENSION_CALIB_ERROR_EST_IMAGE DESCRIPTION = " FITS EDU number: 1 LORRI Error image Calibrated error estimate image - 1-sigma error in photometrically corrected signal - Formula: _______________________ /PmeasI 2 2 / ------ + RN + (fPmeas) sigma = \/ g I --------------------------- FF - Where: sigma is the 1-sigma error pixel I I PmeasI is the observed signal in pixel I after bias subtraction but before smear removal g is the electronics gain (22 e/DN) RN is the electronics noise (1.3 DN) f is the estimated error in the reference flat-field image (0.005) FF is the value of the reference flat-field image at the relevant pixel " SAMPLE_BITS = 32 SAMPLE_TYPE = "IEEE_REAL" AXIS_ORDER_TYPE = "FIRST_INDEX_FASTEST" LINE_DISPLAY_DIRECTION = "UP" SAMPLE_DISPLAY_DIRECTION = "RIGHT" LINE_SAMPLES = 256 LINES = 256 END_OBJECT = EXTENSION_CALIB_ERROR_EST_IMAGE OBJECT = EXTENSION_CALIB_QUALITY_HEADER BYTES = 2880 HEADER_TYPE = "FITS" INTERCHANGE_FORMAT = "BINARY" RECORDS = 1 DESCRIPTION = " This is the FITS header for FITS EDU number: 2 FITS EDU name: LORRI Quality flag image " END_OBJECT = EXTENSION_CALIB_QUALITY_HEADER OBJECT = EXTENSION_CALIB_QUALITY_IMAGE DESCRIPTION = " FITS EDU number: 2 LORRI Quality flag image Calibrated quality image - Zero values are good - Non-zero values flag pixels with known artifact(s) - Non-zero bits in flag pixels identify artifacts: - 1 => Reed-Solomon error - 2 => Defect in one of the reference calib. files - 4 => Permanent CCD defect (e.g., dead pixel) - 8 => Saturated pixel (A/D value of 4095) - 16 => Missing data - 32 => Bad pixel not in any of above categories " SAMPLE_BITS = 16 SAMPLE_TYPE = "MSB_INTEGER" AXIS_ORDER_TYPE = "FIRST_INDEX_FASTEST" LINE_DISPLAY_DIRECTION = "UP" SAMPLE_DISPLAY_DIRECTION = "RIGHT" LINE_SAMPLES = 256 LINES = 256 OFFSET = 32768.0000000 END_OBJECT = EXTENSION_CALIB_QUALITY_IMAGE END