OBJECT = COLUMN NAME = TIME DATA_TYPE = CHARACTER START_BYTE = 1 BYTES = 19 DESCRIPTION = "Event time" FORMAT = A19 COLUMN_NUMBER = 1 MISSING_CONSTANT = 1980-01-01T00:00:00 END_OBJECT = COLUMN OBJECT = COLUMN NAME = VERSION DATA_TYPE = ASCII_INTEGER START_BYTE = 22 BYTES = 3 DESCRIPTION = "Software version" FORMAT = I3 COLUMN_NUMBER = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = KEEPALIVE_STATUS DATA_TYPE = ASCII_INTEGER START_BYTE = 26 BYTES = 1 DESCRIPTION = "Keepalive status, 0 = OK, 1 = defaults used" FORMAT = I1 COLUMN_NUMBER = 3 END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER DATA_TYPE = ASCII_INTEGER START_BYTE = 28 BYTES = 1 DESCRIPTION = "Encounter mode on, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_ARMED DATA_TYPE = ASCII_INTEGER START_BYTE = 30 BYTES = 1 DESCRIPTION = "High voltages automatically on upon boot, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 5 END_OBJECT = COLUMN OBJECT = COLUMN NAME = SAFE_OPERATION DATA_TYPE = ASCII_INTEGER START_BYTE = 32 BYTES = 1 DESCRIPTION = "High voltage command action prohibited, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 6 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FULL_SPECTRUM DATA_TYPE = ASCII_INTEGER START_BYTE = 34 BYTES = 1 DESCRIPTION = "The software should skip the routine for locating the spectrum, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 7 END_OBJECT = COLUMN OBJECT = COLUMN NAME = SIMULATION_FIFO DATA_TYPE = ASCII_INTEGER START_BYTE = 36 BYTES = 1 DESCRIPTION = "The FIFO content should be filled with known data pattern, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 8 END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_SIMULATION DATA_TYPE = ASCII_INTEGER START_BYTE = 38 BYTES = 1 DESCRIPTION = "Simulate the particle hit rate, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 9 END_OBJECT = COLUMN OBJECT = COLUMN NAME = KEEPALIVE_ORIGIN DATA_TYPE = ASCII_INTEGER START_BYTE = 40 BYTES = 2 DESCRIPTION = "Software version used for keepalive default values, 0 = not used, 1 = 5 or 8, 2 = newer, 3 = from version 5 or 8, new parameters initialized from later version" FORMAT = I2 COLUMN_NUMBER = 10 END_OBJECT = COLUMN OBJECT = COLUMN NAME = SC_CLOCK DATA_TYPE = ASCII_INTEGER START_BYTE = 43 BYTES = 10 DESCRIPTION = "32-bit S/C clock received from Stardust" FORMAT = I10 UNIT = "SECOND" COLUMN_NUMBER = 11 MISSING_CONSTANT = 0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FINE_TIME DATA_TYPE = ASCII_INTEGER START_BYTE = 54 BYTES = 10 DESCRIPTION = "32-bit CIDA clock, starts from 0 at boot, resolution 1 ms" FORMAT = I10 UNIT = "MILLISECOND" COLUMN_NUMBER = 12 END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_CLOCK DATA_TYPE = ASCII_INTEGER START_BYTE = 65 BYTES = 5 DESCRIPTION = "16-bit encounter clock received from Stardust. Starts from 0xFFFF 5 hours before closest encounter, 0x8000 at that point, 0x0000 5h after the encounter" FORMAT = I5 COLUMN_NUMBER = 13 END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_RATE DATA_TYPE = ASCII_INTEGER START_BYTE = 71 BYTES = 3 DESCRIPTION = "Event rate hits/second. 255, if no events. 254, if more than 253 events per seconds" FORMAT = I3 COLUMN_NUMBER = 14 END_OBJECT = COLUMN OBJECT = COLUMN NAME = PARTITION DATA_TYPE = ASCII_INTEGER START_BYTE = 75 BYTES = 3 DESCRIPTION = "Partition requested for data storage" FORMAT = I3 COLUMN_NUMBER = 15 END_OBJECT = COLUMN OBJECT = COLUMN NAME = LARGE_EVENT_RATE DATA_TYPE = ASCII_INTEGER START_BYTE = 79 BYTES = 3 DESCRIPTION = "Large event rate hits/second. 255, if no events 254, if more than 253 events per seconds" FORMAT = I3 COLUMN_NUMBER = 16 END_OBJECT = COLUMN OBJECT = COLUMN NAME = LARGE_EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 83 BYTES = 10 DESCRIPTION = "Total number of large events" FORMAT = I10 COLUMN_NUMBER = 17 END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 94 BYTES = 10 DESCRIPTION = "Total number of events" FORMAT = I10 COLUMN_NUMBER = 18 END_OBJECT = COLUMN OBJECT = COLUMN NAME = BYTES_SENT DATA_TYPE = ASCII_INTEGER START_BYTE = 105 BYTES = 10 DESCRIPTION = "Total number of bytes sent to S/C" FORMAT = I10 COLUMN_NUMBER = 19 END_OBJECT = COLUMN OBJECT = COLUMN NAME = SEQUENCE_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 116 BYTES = 10 DESCRIPTION = "Event sequential counter" FORMAT = I10 COLUMN_NUMBER = 20 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_PRI_BOARD DATA_TYPE = ASCII_INTEGER START_BYTE = 127 BYTES = 1 DESCRIPTION = "FDAQ primary board on, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 21 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_AUX_BOARD DATA_TYPE = ASCII_INTEGER START_BYTE = 129 BYTES = 1 DESCRIPTION = "FDAQ auxiliary board on, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 22 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_HI_SENS_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 131 BYTES = 1 DESCRIPTION = "FDAQ high sensitivity 1 used, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 23 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_HI_SENS_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 133 BYTES = 1 DESCRIPTION = "FDAQ high sensitivity 2 used, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 24 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_LO_SENS_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 135 BYTES = 1 DESCRIPTION = "FDAQ low sensitivity 1 used, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 25 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_LO_SENS_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 137 BYTES = 1 DESCRIPTION = "FDAQ low sensitivity 2 used, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 26 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 139 BYTES = 1 DESCRIPTION = "FDAW target signal enabled on low delayed channel, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 27 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_AUTOCAL DATA_TYPE = ASCII_INTEGER START_BYTE = 141 BYTES = 1 DESCRIPTION = "FDAQ calibration staircase signal enabled, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 28 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_PROTECTION DATA_TYPE = ASCII_INTEGER START_BYTE = 143 BYTES = 1 DESCRIPTION = "FDAQ latch-up detection enabled, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 29 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_CAL_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 145 BYTES = 1 DESCRIPTION = "FDAQ target calibration signal used, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 30 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_CONVERTER DATA_TYPE = ASCII_INTEGER START_BYTE = 147 BYTES = 1 DESCRIPTION = "High voltages converter on, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 31 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_RFB DATA_TYPE = ASCII_INTEGER START_BYTE = 149 BYTES = 1 DESCRIPTION = "Reflector board high voltage enabled, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_MM1 DATA_TYPE = ASCII_INTEGER START_BYTE = 151 BYTES = 1 DESCRIPTION = "Multiplier high voltage enable, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 33 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_PRI_LATCHUP DATA_TYPE = ASCII_INTEGER START_BYTE = 153 BYTES = 1 DESCRIPTION = "FDAQ primary board latch-up, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 34 END_OBJECT = COLUMN OBJECT = COLUMN NAME = FDAQ_AUX_LATCHUP DATA_TYPE = ASCII_INTEGER START_BYTE = 155 BYTES = 1 DESCRIPTION = "FDAQ auxiliary board latch-up, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 35 END_OBJECT = COLUMN OBJECT = COLUMN NAME = TRIGGER_INTEG DATA_TYPE = ASCII_INTEGER START_BYTE = 157 BYTES = 3 DESCRIPTION = "FDAQ integral trigger DA level" FORMAT = I3 COLUMN_NUMBER = 36 END_OBJECT = COLUMN OBJECT = COLUMN NAME = TRIGGER_PULSE DATA_TYPE = ASCII_INTEGER START_BYTE = 161 BYTES = 3 DESCRIPTION = "FDAQ pulse trigger DA level" FORMAT = I3 COLUMN_NUMBER = 37 END_OBJECT = COLUMN OBJECT = COLUMN NAME = MULTIPLEXER_INDEX DATA_TYPE = ASCII_INTEGER START_BYTE = 165 BYTES = 2 DESCRIPTION = "Housekeeping multiplexer index" FORMAT = I2 COLUMN_NUMBER = 38 END_OBJECT = COLUMN OBJECT = COLUMN NAME = MULTIPLEXER_VALUE DATA_TYPE = ASCII_INTEGER START_BYTE = 168 BYTES = 3 DESCRIPTION = "Housekeeping multiplexer value, uncalibrated" FORMAT = I3 COLUMN_NUMBER = 39 END_OBJECT = COLUMN OBJECT = COLUMN NAME = MM1_SETUP DATA_TYPE = ASCII_INTEGER START_BYTE = 172 BYTES = 3 DESCRIPTION = "Multiplier high voltage DA setup value" FORMAT = I3 COLUMN_NUMBER = 40 END_OBJECT = COLUMN OBJECT = COLUMN NAME = MM1_VALUE DATA_TYPE = ASCII_REAL START_BYTE = 176 BYTES = 4 DESCRIPTION = "Multiplier high voltage calibrated value" FORMAT = "F4.1" UNIT = "KILOVOLT" COLUMN_NUMBER = 41 END_OBJECT = COLUMN OBJECT = COLUMN NAME = RFB_VALUE DATA_TYPE = ASCII_REAL START_BYTE = 181 BYTES = 4 DESCRIPTION = "Reflector high voltage calibrated value" FORMAT = "F4.1" UNIT = "KILOVOLT" COLUMN_NUMBER = 42 END_OBJECT = COLUMN OBJECT = COLUMN NAME = ADC_STATUS DATA_TYPE = ASCII_INTEGER START_BYTE = 186 BYTES = 1 DESCRIPTION = "AD-status, 0 = ready, 1 = busy" FORMAT = I1 COLUMN_NUMBER = 43 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_SAFE DATA_TYPE = ASCII_INTEGER START_BYTE = 188 BYTES = 1 DESCRIPTION = "High voltage safe, 0 = disconnected, 1 = safe" FORMAT = I1 COLUMN_NUMBER = 44 END_OBJECT = COLUMN OBJECT = COLUMN NAME = TEST_CONNECTOR DATA_TYPE = ASCII_INTEGER START_BYTE = 190 BYTES = 1 DESCRIPTION = "Test connector, 0 = unplugged, 1 = plugged" FORMAT = I1 COLUMN_NUMBER = 45 END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEGATIVE_ION_MODE DATA_TYPE = ASCII_INTEGER START_BYTE = 192 BYTES = 1 DESCRIPTION = "Negative ion mode, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 46 END_OBJECT = COLUMN OBJECT = COLUMN NAME = POSITIVE_ION_MODE DATA_TYPE = ASCII_INTEGER START_BYTE = 194 BYTES = 1 DESCRIPTION = "Positive IO mode, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 47 END_OBJECT = COLUMN OBJECT = COLUMN NAME = SMALL_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 196 BYTES = 1 DESCRIPTION = "Small target, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 48 END_OBJECT = COLUMN OBJECT = COLUMN NAME = LARGE_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 198 BYTES = 1 DESCRIPTION = "Large target, 0 = no, 1 = yes" FORMAT = I1 COLUMN_NUMBER = 49 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HI_SENS_DELAYED DATA_TYPE = ASCII_INTEGER START_BYTE = 200 BYTES = 3 DESCRIPTION = "High sensitivity delayed DA-value" FORMAT = I3 COLUMN_NUMBER = 50 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HI_SENS_STRAIGHT DATA_TYPE = ASCII_INTEGER START_BYTE = 204 BYTES = 3 DESCRIPTION = "High sensitivity straight DA-value" FORMAT = I3 COLUMN_NUMBER = 51 END_OBJECT = COLUMN OBJECT = COLUMN NAME = LO_SENS_DELAYED DATA_TYPE = ASCII_INTEGER START_BYTE = 208 BYTES = 3 DESCRIPTION = "Low sensitivity delayed DA-value" FORMAT = I3 COLUMN_NUMBER = 52 END_OBJECT = COLUMN OBJECT = COLUMN NAME = LO_SENS_STRAIGHT DATA_TYPE = ASCII_INTEGER START_BYTE = 212 BYTES = 3 DESCRIPTION = "Low sensitivity straight DA-value" FORMAT = I3 COLUMN_NUMBER = 53 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 216 BYTES = 5 DESCRIPTION = "First of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 54 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 222 BYTES = 5 DESCRIPTION = "Second of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 55 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_3 DATA_TYPE = ASCII_INTEGER START_BYTE = 228 BYTES = 5 DESCRIPTION = "Third of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 56 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_4 DATA_TYPE = ASCII_INTEGER START_BYTE = 234 BYTES = 5 DESCRIPTION = "Fourth of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 57 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_5 DATA_TYPE = ASCII_INTEGER START_BYTE = 240 BYTES = 5 DESCRIPTION = "Fifth of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 58 END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMMAND_6 DATA_TYPE = ASCII_INTEGER START_BYTE = 246 BYTES = 5 DESCRIPTION = "Last of the last 6 commands" FORMAT = I5 COLUMN_NUMBER = 59 END_OBJECT = COLUMN