OBJECT = COLUMN NAME = EDF_TYPE DATA_TYPE = CHARACTER START_BYTE = 3 BYTES = 4 DESCRIPTION = "EDF type: ScHs = uncompressed event RiHs = compressed event WaHs = wavelet compressed event Haus = housekeeping packet KeeD = configuration parameters KeeS = FDAQ initialization upon start KeeC = FDAQ initialization by command KeeL = FDAQ initialization after latch-up INFO = interrupt system information GLOB = global variables" FORMAT = A4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P5V DATA_TYPE = ASCII_REAL START_BYTE = 9 BYTES = 8 DESCRIPTION = "+5 V voltage" FORMAT = "F8.3" UNIT = "VOLT" SCALING_FACTOR = 0.025 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_M5V DATA_TYPE = ASCII_REAL START_BYTE = 18 BYTES = 8 DESCRIPTION = "-5 V voltage" FORMAT = "F8.3" UNIT = "VOLT" SCALING_FACTOR = -0.025 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P15V DATA_TYPE = ASCII_REAL START_BYTE = 27 BYTES = 8 DESCRIPTION = "+15 V voltage" FORMAT = "F8.2" UNIT = "VOLT" SCALING_FACTOR = 0.075 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P5HV DATA_TYPE = ASCII_REAL START_BYTE = 36 BYTES = 8 DESCRIPTION = "+5 V voltage at high voltage part" FORMAT = "F8.2" UNIT = "VOLT" SCALING_FACTOR = 0.025 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P15HV DATA_TYPE = ASCII_REAL START_BYTE = 45 BYTES = 8 DESCRIPTION = "+15 V voltage at high voltage part" FORMAT = "F8.2" UNIT = "VOLT" SCALING_FACTOR = 0.75 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_M15V DATA_TYPE = ASCII_REAL START_BYTE = 54 BYTES = 8 DESCRIPTION = "-15 V voltage" FORMAT = "F8.2" UNIT = "VOLT" SCALING_FACTOR = -0.75 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_PROBE DATA_TYPE = ASCII_REAL START_BYTE = 63 BYTES = 8 DESCRIPTION = "High voltage probe, value over 200 means positive high voltages are on" FORMAT = "F8.0" MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_SPARED DATA_TYPE = ASCII_REAL START_BYTE = 72 BYTES = 8 DESCRIPTION = "Spare channel D" FORMAT = "F8.0" MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_SPARE DATA_TYPE = ASCII_REAL START_BYTE = 81 BYTES = 8 DESCRIPTION = "Spare channel" FORMAT = "F8.0" MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P5I DATA_TYPE = ASCII_REAL START_BYTE = 90 BYTES = 8 DESCRIPTION = "+5 V current" FORMAT = "F8.3" UNIT = "AMPERE" SCALING_FACTOR = 0.006275 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_M5I DATA_TYPE = ASCII_REAL START_BYTE = 99 BYTES = 8 DESCRIPTION = "-5 V current" FORMAT = "F8.3" UNIT = "AMPERE" SCALING_FACTOR = 0.0004549 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_P15I DATA_TYPE = ASCII_REAL START_BYTE = 108 BYTES = 8 DESCRIPTION = "+15 V current" FORMAT = "F8.3" UNIT = "AMPERE" SCALING_FACTOR = 0.004314 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_TARGET_T DATA_TYPE = ASCII_REAL START_BYTE = 117 BYTES = 8 DESCRIPTION = "Target temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_MM1_T DATA_TYPE = ASCII_REAL START_BYTE = 126 BYTES = 8 DESCRIPTION = "MM-1 temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_SCIF_T DATA_TYPE = ASCII_REAL START_BYTE = 135 BYTES = 8 DESCRIPTION = "S/C interface temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_CPU_T DATA_TYPE = ASCII_REAL START_BYTE = 144 BYTES = 8 DESCRIPTION = "CPU temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_LVC_T DATA_TYPE = ASCII_REAL START_BYTE = 153 BYTES = 8 DESCRIPTION = "Low voltage converter temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_HK_T DATA_TYPE = ASCII_REAL START_BYTE = 162 BYTES = 8 DESCRIPTION = "Housekeeping temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_FDAQP_T DATA_TYPE = ASCII_REAL START_BYTE = 171 BYTES = 8 DESCRIPTION = "Primary FDAQ temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_FDAQA_T DATA_TYPE = ASCII_REAL START_BYTE = 180 BYTES = 8 DESCRIPTION = "Auxiliary FDAQ temperature" FORMAT = "F8.0" UNIT = "KELVIN" SCALING_FACTOR = 1.0 OFFSET = 202.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_MM1_V DATA_TYPE = ASCII_REAL START_BYTE = 189 BYTES = 8 DESCRIPTION = "MM-1 voltage" FORMAT = "F8.2" UNIT = "KILOVOLT" SCALING_FACTOR = 0.03958 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_RFB DATA_TYPE = ASCII_REAL START_BYTE = 198 BYTES = 8 DESCRIPTION = "Reflector voltage" FORMAT = "F8.2" UNIT = "KILOVOLT" SCALING_FACTOR = 0.00975 OFFSET = 0.0 MISSING_CONSTANT = +1.E32 END_OBJECT = COLUMN OBJECT = COLUMN NAME = HK_TIMEOUT DATA_TYPE = ASCII_INTEGER START_BYTE = 207 BYTES = 5 DESCRIPTION = "Count of telemetry transfer time-outs" FORMAT = "I5" SCALING_FACTOR = 1.0 OFFSET = 0.0 MISSING_CONSTANT = 65535 END_OBJECT = COLUMN