SIMPLE = T / Standard FITS format (rev Dec 79) BITPIX = 8 / Character Information NAXIS = 0 / No image data array present BLOCKED = T / Records may be blocked... EXTEND = T / There may be standard extension ORIGIN = 'ESO-MIDAS' / E S O MIDAS System (on VAX/VMS) FILENAME= 'OPE3.TBL ' / Name of the file DATE = '17/02/89' / Date tape was written END XTENSION= 'TABLE ' / TABLE EXTENSION (REV.1986) BITPIX = 8 / 8-bits per "pixel" NAXIS = 2 / Simple 2-D matrix NAXIS1 = 59 / No. of characters per row NAXIS2 = 700 / The number of rows PCOUNT = 0 / No "random" parameters GCOUNT = 1 / Only one group TFIELDS = 5 / Number of columns EXTNAME = 'OPE3.TBL ' / Name of the table TTYPE1 = '0.441 CONTINUUM ' / Type of the field (column label) TBCOL1 = 1 / Starting character position TFORM1 = 'G12.4 ' / Fortran format TUNIT1 = 'WATT/CM2/STR/ANG' / Physical units of the field TTYPE2 = '0.576 CONTINUUM ' / Type of the field (column label) TBCOL2 = 14 / Starting character position TFORM2 = 'G12.4 ' / Fortran format TUNIT2 = 'WATT/CM2/STR/ANG' / Physical units of the field TTYPE3 = '0.718 CONTINUUM ' / Type of the field (column label) TBCOL3 = 27 / Starting character position TFORM3 = 'G12.4 ' / Fortran format TUNIT3 = 'WATT/CM2/STR/ANG' / Physical units of the field TTYPE4 = 'CO+ ' / Type of the field (column label) TBCOL4 = 40 / Starting character position TFORM4 = 'G12.4 ' / Fortran format TUNIT4 = 'WATT/CM2/STR/ANG' / Physical units of the field TTYPE5 = 'COMETOCENTRIC DISTANCE' TBCOL5 = 53 / Starting character position TFORM5 = 'I6 ' / Fortran format TUNIT5 = 'KILOMETERS ' / Physical units of the field HISTORY GIOTTO - HOPE OPTICAL PROBE EXPERIMENT HISTORY PHASE 1 HISTORY OBSEVATIONS 13-14 MARCH 1986 HISTORY DATA PREPARED 17 FEB 1989 BY: HISTORY LAB. D'ASTRONOMIE SPATIALE HISTORY (MARSEILLE-FRANCE) AND HISTORY SPACE LABORATORY HISTORY ASTRONOMY DEPARTMENT HISTORY UNIVERSITY OF FLORIDA HISTORY CONTACT: HISTORY A.LLEBARIA, P.LAMY AT L.A.S. HISTORY FRANK GIOVANNE AT ASTRONOMY DEPT. HISTORY UNIVERSITY OF FLORIDA HISTORY COMMENT -----ADDED BY A.C.LEVASSEUR-REGOURD AT CNRS---------- COMMENT Absolute Calibration COMMENT Due to the reduced amount of time available for calibrations after COMMENT the flight detector was available, the absolute-radiance sensitivity COMMENT of the instrument had been inferred by considering the individual COMMENT spectral transmissions of each optical component, the field of view COMMENT of the instrument, the photocathode spectral sensitivity and the total COMMENT responsivity of the microchannel plate photomultiplier (Giovane, F., COMMENT et al. 1991). The results were the following: COMMENT COMMENT Channel Wavelength Bandpass Responsivity COMMENT nm 50% peak, nm 10**-7 Wm**-2sr**-1microm**-1ct**-1 COMMENT Blue 442 5 2.09 COMMENT Green 576 10 0.88 COMMENT Red 718 4 4.40 COMMENT OH 310 6 16.81 COMMENT CN 387 4 8.20 COMMENT CO+ 424 4 1.34 COMMENT C2 514 4 3.75 COMMENT COMMENT The on-board calibration tritium-phosphor source (mounted on the COMMENT back of the baffle cover), which allowed the instrument to be COMMENT tested during the pre-Halley-encounter cruise, was released with COMMENT the baffle cover prior to Halley encounter. " COMMENT END