DIF-C-MRI-3/4-9P-ENCOUNTER-V3.0 Catalog ======= o In the dataset.cat file description, please add full citations to the Calibration papers (i.e., as footnotes in the text – in addition to the REFERENCE objects that also exist). o In dataset.cat. the CITATION_DESC year must be '2014' since this is when the data were reviewed and released to the public. o In dataset.cat, the description of the east flip for lookback images is incorrect. (In the paragraph beginning, "Using this convention for Tempel 1 approach images...".) See Jianyang's slide 17 for the geometry and correct orientation. o In dataset.cat: - line 138: typo: Change "KLAASENTAL2005" to "KLAASENETAL2005". - REFERENCE_KEY_ID = "HAMPTONETAL2005" shows up twice. - Center wavelength of CLEAR6 is 650 nm, not 600 nm - Line 613: typo: “as strong as” o The required instrument host catalog file is missing for the impactor. o In dif.cat: REFERENCE_KEY_ID = "RIEBER&SHARROW2009" is not found in ref.cat. If this is the same reference as already exists in the PDS catalog, add that REFERENCE object. Otherwise, change the REFERENCE_KEY_ID to a unique value and supply the corresponding reference object. o In voldesc.cat, this data set is not an amalgam of pre-xisting volumes and, therefore, must have a valid VOLUME_ID - it cannot end in "X". The VOLUME_VERSION_ID must be set appropriately for the valid VOLUME_ID. Documents ========= o Ensure these data sets have the latest versions of these document files: day_of_year_calendar.lbl epoxi_cal_pipeline_summ.lbl epoxi_sis.lbl instruments_hampton.lbl pdsdd_epoxi.lbl quaternion_desc.lbl o In epoxi_sis.pdf: - This document says labels for HRIV, MRI, and ITS level 3/4 data, PDS keyword PROCESSING_HISTORY_TEXT contain FLAT_PRO= FLATCONS= FLATTEMP= CALWINDW= CALWINPY= but the sample labels in the SIS's 4.4.4.1 and 4.4.4.2 do not. - p. 27: "DIF-L-HRII-3_4-EPOXI-LUNAR-CALS-V1.0" should have a / not a _ i.e. "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0" - epoxy_sis.pdf pages 47-9 the figures are misaligned with the text. This needs to be corrected in every copy of the document in all data sets. o There are summary files with names like “hriv_3_4_epoxi_garrad.pdf”. In at least some of these labels in some data sets, the Julian Date field is described as being in the form “YYYYMMDD”. This needs to be fixed if it applies to this data set. o In places that describe the file naming convention, there needs to be a clear indication of which time (beginning, middle, end) is used for creating the file name. o Check that the metric for applying destriping is plainly stated in the calibration documentation. o In the file mri_translate_product_id.lbl: line 10: put a comma after the entry "DIF-C-MRI-3/4-9P-ENCOUNTER-V3.0" CALIB/ ====== o In badpix/mrivis_020601_1_8_999.lbl: Remove quotes around the value of SAMPLE_BITS/ o In bias/mrivis_020601_1_6.lbl: line 12: Missing a closing double quote for the value for INSTRUMENT_NAME. o In bias/mrivis_020601_1_6.lbl: missing line after INSTRUMENT_NAME = "DEEP IMPACT MEDIUM RESOLUTION INSTRUMENT o In drkmodel/*.lbl: AXIS_NAME = ("SAMPLES", "LINES", "CURRENT_COEFFICIENTS") is legal, but "SAMPLE" and "LINE" (singular) are much more common. DATA/ ===== o In the files: rad/2005/185/mv05070405_9001012_001_r.lbl radrev/2005/185/mv05070405_9001012_001_rr.lbl There are odd and invalid values for "EPOXI:COMPRESSED_IMAGE_VALUE".