PDS_VERSION_ID = PDS3 RECORD_TYPE = "STREAM" OBJECT = TEXT NOTE = "Known anomalies concerning this EPOXI data set" PUBLICATION_DATE = 2010-11-26 END_OBJECT = TEXT END This file describes known anomalies concerning this EPOXI data set as of 26 November 2010. Keywords in the Primary FITS Header =================================== - The correct unit for NOMPXLSZ and RECPXLSZ is radian, not microradian as specified in the comment. For HRII spectra, the 2x2-pixel binned value is always given (divide by two for unbinned modes) for NOMPXLSZ and RECPXLSZ in the FITS header and for VERTICAL_PIXEL_SCALE in the PDS labels. - MSNPHASE was not encoded for the EPOCh Mars observation and is set to 'COMMISSIONING', the default value. It should be 'CRUISE 2'. - RANGE, CTRDIST, and RANGECEN have intentionally been set to the same value: the distance from the spacecraft to the center of the target.