PDS_VERSION_ID      = PDS3                                                    
RECORD_TYPE         = "UNDEFINED"                                             
LABEL_REVISION_NOTE = "                                                       
  2012-12-10  EPOXI:McLaughlin  Cloned HARTLEY2_CAL_PIPELINE_SUMM.DOC and     
    revised it to reflect IR improvements implemented in the EPOXI            
    calibration pipeline from mid 2012 through early 2012 and to address      
    data that were reprocessed using that version of the pipeline:            
    Calibrated HRII Hartley2 V2.0, Calibrated HRII/HRIV/MRI Earth V2.0,       
    Calibrated HRIV/MRI Mars V2.0, Calibrated HRII Mars V1.0, Calibrated      
    HRII EPOXI Lunar Cals V1.0, Calibrated HRII/HRIV/MRI/ITS Tempel1 V3.0;    
    adjusted DSID list to include only the datasets to which this report      
    applies.                                                                  
  2013-01-30  EPOXI:McLaughlin  Revised doc to reflect minor changes to the   
    EPOXI calibration pipeline on 23-29 Jan 2013 for HRII Hartley2 V2.0       
    processing.                                                               
"                                                                             
                                                                              
^PDF_DOCUMENT       = "EPOXI_CAL_PIPELINE_SUMM.PDF"                           
                                                                              
DATA_SET_ID         = { "DI-C-HRII/HRIV/MRI/ITS-6-DOC-SET-V4.0",              
                        "DIF-CAL-HRII/HRIV/MRI-6-EPOXI-TEMPS-V1.0",           
                        "DIF-CAL-HRII-2-EPOXI-CALIBRATIONS-V2.0",             
                        "DIF-CAL-HRIV-2-EPOXI-CALIBRATIONS-V2.0",             
                        "DIF-CAL-MRI-2-EPOXI-CALIBRATIONS-V2.0",              
                        "DIF-C-HRII-2-EPOXI-HARTLEY2-V1.0",                   
                        "DIF-C-HRII-3/4-EPOXI-HARTLEY2-V2.0",                 
                        "DIF-C-HRIV-2-EPOXI-HARTLEY2-V1.0",                   
                        "DIF-C-HRIV-3/4-EPOXI-HARTLEY2-V1.0",                 
                        "DIF-C-MRI-2-EPOXI-HARTLEY2-V1.0",                    
                        "DIF-C-MRI-3/4-EPOXI-HARTLEY2-V1.0",                  
                        "DIF-E-HRII-3/4-EPOXI-EARTH-V2.0",                    
                        "DIF-E-HRIV-3/4-EPOXI-EARTH-V2.0",                    
                        "DIF-E-MRI-3/4-EPOXI-EARTH-V2.0",                     
                        "DIF-M-HRII-3/4-EPOXI-MARS-V1.0",                     
                        "DIF-M-HRIV-3/4-EPOXI-MARS-V2.0",                     
                        "DIF-M-MRI-3/4-EPOXI-MARS-V2.0",                      
                        "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0",               
                        "DIF-C-HRII-3/4-9P-ENCOUNTER-V3.0",                   
                        "DIF-C-HRIV-3/4-9P-ENCOUNTER-V3.0",                   
                        "DIF-C-MRI-3/4-9P-ENCOUNTER-V3.0",                    
                        "DII-C-ITS-3/4-9P-ENCOUNTER-V3.0" }                   
                                                                              
OBJECT                = PDF_DOCUMENT                                          
  DOCUMENT_NAME       = "EPOXI Calibration Pipeline Summary"                  
  DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT"                                  
  INTERCHANGE_FORMAT  = "BINARY"                                              
  DOCUMENT_FORMAT     = "ADOBE PDF"                                           
  DESCRIPTION         = "This document summarizes the EPOXI calibration       
    pipeline as of January 2013 used for processing data acquired during      
    the Hartley 2 Encounter from August 2010 to February 2011.  The same      
    pipeline was also used to recalibrate Earth and Mars data acquired        
    in 2008 and 2009 for the EPOCh phase of the EPOXI mission as well         
    as EPOXI HRII Lunar Calibrations and Deep Impact HRII/HRIV/MRI/ITS        
    prime mission data.                                                       
                                                                              
    The EPOXI pipeline is based on the one developed for the Deep Impact      
    mission as described by Klaasen, et al. (2008).  The document             
    describes the enhancement made to that baseline.  For a thoruogh          
    discussion of the calibration process for EPOXI, please refer to          
    the publication, 'EPOXI Instrument Calibration' by Klaasen, et al.        
    (2012)."                                                                  
  PUBLICATION_DATE    = 2013-01-30                                            
END_OBJECT            = PDF_DOCUMENT                                          
                                                                              
END