PDS_VERSION_ID = PDS3 RECORD_TYPE = "UNDEFINED" LABEL_REVISION_NOTE = " 2012-12-10 EPOXI:McLaughlin Cloned HARTLEY2_CAL_PIPELINE_SUMM.DOC and revised it to reflect IR improvements implemented in the EPOXI calibration pipeline from mid 2012 through early 2012 and to address data that were reprocessed using that version of the pipeline: Calibrated HRII Hartley2 V2.0, Calibrated HRII/HRIV/MRI Earth V2.0, Calibrated HRIV/MRI Mars V2.0, Calibrated HRII Mars V1.0, Calibrated HRII EPOXI Lunar Cals V1.0, Calibrated HRII/HRIV/MRI/ITS Tempel1 V3.0; adjusted DSID list to include only the datasets to which this report applies. 2013-01-30 EPOXI:McLaughlin Revised doc to reflect minor changes to the EPOXI calibration pipeline on 23-29 Jan 2013 for HRII Hartley2 V2.0 processing. 2013-08-17 EPOXI:McLaughlin Added DSIDs for Raw and Calibrated comets Garradd and ISON V1.0 datasets and EPOXI Thermal Telem V3.0 dataset. 2014-01-30 EPOXI:McLaughlin Added DSID for new calibrated V3.0 EPOXI HRII Hartley 2 dataset; Document updated by EPOXI IR and VIS teams for V3.0 EPOXI Hartley 2, V1.0 EPOXI Lunar Cals, and V3.0 Deep Impact IR/HRIV/MRI/ITS Tempel1 calibrated data. 2014-03-10 EPOXI:McLaughlin HRII sci team made minor revisions to this doc for V3.0 EPOXI HRII Hartley 2 dataset. 2014-05-11 EPOXI:McLaughlin Resolved liens from Mar 2014 review: Removed DIF-C-HRIV-*-EPOXI-ISON-V1.0 from DSID. " ^PDF_DOCUMENT = "EPOXI_CAL_PIPELINE_SUMM.PDF" DATA_SET_ID = { "DI-C-HRII/HRIV/MRI/ITS-6-DOC-SET-V4.0", "DIF-CAL-HRII/HRIV/MRI-6-EPOXI-TEMPS-V2.0", "DIF-CAL-HRII/HRIV/MRI-6-EPOXI-TEMPS-V2.1", "DIF-CAL-HRII-2-EPOXI-CALIBRATIONS-V2.0", "DIF-CAL-HRIV-2-EPOXI-CALIBRATIONS-V2.0", "DIF-CAL-MRI-2-EPOXI-CALIBRATIONS-V2.0", "DIF-C-HRII-2-EPOXI-HARTLEY2-V1.0", "DIF-C-HRII-3/4-EPOXI-HARTLEY2-V2.0", "DIF-C-HRIV-2-EPOXI-HARTLEY2-V1.0", "DIF-C-HRIV-3/4-EPOXI-HARTLEY2-V1.0", "DIF-C-MRI-2-EPOXI-HARTLEY2-V1.0", "DIF-C-MRI-3/4-EPOXI-HARTLEY2-V1.0", "DIF-E-HRII-3/4-EPOXI-EARTH-V2.0", "DIF-E-HRIV-3/4-EPOXI-EARTH-V2.0", "DIF-E-MRI-3/4-EPOXI-EARTH-V2.0", "DIF-M-HRII-3/4-EPOXI-MARS-V1.0", "DIF-M-HRIV-3/4-EPOXI-MARS-V2.0", "DIF-M-MRI-3/4-EPOXI-MARS-V2.0", "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0", "DIF-C-HRII-3/4-9P-ENCOUNTER-V3.0", "DIF-C-HRIV-3/4-9P-ENCOUNTER-V3.0", "DIF-C-MRI-3/4-9P-ENCOUNTER-V3.0", "DII-C-ITS-3/4-9P-ENCOUNTER-V3.0", "DIF-CAL-HRII/HRIV/MRI-6-EPOXI-TEMPS-V3.0", "DIF-C-HRII-2-EPOXI-GARRADD-V1.0", "DIF-C-HRII-3/4-EPOXI-GARRADD-V1.0", "DIF-C-HRIV-2-EPOXI-GARRADD-V1.0", "DIF-C-HRIV-3/4-EPOXI-GARRADD-V1.0", "DIF-C-MRI-2-EPOXI-GARRADD-V1.0", "DIF-C-MRI-3/4-EPOXI-GARRADD-V1.0", "DIF-C-HRII-2-EPOXI-ISON-V1.0", "DIF-C-HRII-3/4-EPOXI-ISON-V1.0", "DIF-C-MRI-2-EPOXI-ISON-V1.0", "DIF-C-MRI-3/4-EPOXI-ISON-V1.0", "DIF-C-HRII-3/4-EPOXI-HARTLEY2-V3.0" } OBJECT = PDF_DOCUMENT DOCUMENT_NAME = "EPOXI Calibration Pipeline Summary" DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT" INTERCHANGE_FORMAT = "BINARY" DOCUMENT_FORMAT = "ADOBE PDF" DESCRIPTION = "This document summarizes the EPOXI calibration pipeline as of March 2014 used for processing data acquired during the Hartley 2 Encounter from August 2010 to February 2011. The same pipeline was also used to process these data during 2013 and 2014: - Recalibrate version 2.0 HRII/HRIV/MRI Earth data acquired in 2008 and 2009 for the EPOCh phase of the EPOXI mission - Recalibrate version 1.0 HRII and version 2.0 HRIV/MRI Mars data acquired in 2009 for the EPOCh phase of the EPOXI mission - Calibrate version 1.0 EPOXI HRII Lunar Calibrations acquired in 2007 through 2009 - Recalibrate version 3.0 Deep Impact HRII/HRIV/MRI/ITS prime mission data acquired in 2005 - Calibrate version 1.0 EPOXI comet Garradd data acquired in 2012 - Calibrate version 1.0 EPOXI comet ISON data acquired in 2013 - Recalibrate version 3.0 EPOXI HRII Hartley 2 spectra acquired in 2010; in particular dark subtraction was improved for spectra on DOYs 2010/307 and 2010/311-313. The EPOXI pipeline is based on the one developed for the Deep Impact mission as described by Klaasen, et al. (2008). The document describes the enhancement made to that baseline. For a thoruogh discussion of the calibration process for EPOXI, please refer to the publication, 'EPOXI Instrument Calibration' by Klaasen, et al. (2013)." PUBLICATION_DATE = 2014-05-11 END_OBJECT = PDF_DOCUMENT END