PDS_VERSION_ID = PDS3 RECORD_TYPE = "UNDEFINED" LABEL_REVISION_NOTE = " 2012-12-10 EPOXI:McLaughlin Cloned HARTLEY2_CAL_PIPELINE_SUMM.DOC and revised it to reflect IR improvements implemented in the EPOXI calibration pipeline from mid 2012 through early 2012 and to address data that were reprocessed using that version of the pipeline: Calibrated HRII Hartley2 V2.0, Calibrated HRII/HRIV/MRI Earth V2.0, Calibrated HRIV/MRI Mars V2.0, Calibrated HRII Mars V1.0, Calibrated HRII EPOXI Lunar Cals V1.0, Calibrated HRII/HRIV/MRI/ITS Tempel1 V3.0; adjusted DSID list to include only the datasets to which this report applies. 2013-01-30 EPOXI:McLaughlin Revised doc to reflect minor changes to the EPOXI calibration pipeline on 23-29 Jan 2013 for HRII Hartley2 V2.0 processing. " ^PDF_DOCUMENT = "EPOXI_CAL_PIPELINE_SUMM.PDF" DATA_SET_ID = { "DI-C-HRII/HRIV/MRI/ITS-6-DOC-SET-V4.0", "DIF-CAL-HRII/HRIV/MRI-6-EPOXI-TEMPS-V1.0", "DIF-CAL-HRII-2-EPOXI-CALIBRATIONS-V2.0", "DIF-CAL-HRIV-2-EPOXI-CALIBRATIONS-V2.0", "DIF-CAL-MRI-2-EPOXI-CALIBRATIONS-V2.0", "DIF-C-HRII-2-EPOXI-HARTLEY2-V1.0", "DIF-C-HRII-3/4-EPOXI-HARTLEY2-V2.0", "DIF-C-HRIV-2-EPOXI-HARTLEY2-V1.0", "DIF-C-HRIV-3/4-EPOXI-HARTLEY2-V1.0", "DIF-C-MRI-2-EPOXI-HARTLEY2-V1.0", "DIF-C-MRI-3/4-EPOXI-HARTLEY2-V1.0", "DIF-E-HRII-3/4-EPOXI-EARTH-V2.0", "DIF-E-HRIV-3/4-EPOXI-EARTH-V2.0", "DIF-E-MRI-3/4-EPOXI-EARTH-V2.0", "DIF-M-HRII-3/4-EPOXI-MARS-V1.0", "DIF-M-HRIV-3/4-EPOXI-MARS-V2.0", "DIF-M-MRI-3/4-EPOXI-MARS-V2.0", "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0", "DIF-C-HRII-3/4-9P-ENCOUNTER-V3.0", "DIF-C-HRIV-3/4-9P-ENCOUNTER-V3.0", "DIF-C-MRI-3/4-9P-ENCOUNTER-V3.0", "DII-C-ITS-3/4-9P-ENCOUNTER-V3.0" } OBJECT = PDF_DOCUMENT DOCUMENT_NAME = "EPOXI Calibration Pipeline Summary" DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT" INTERCHANGE_FORMAT = "BINARY" DOCUMENT_FORMAT = "ADOBE PDF" DESCRIPTION = "This document summarizes the EPOXI calibration pipeline as of January 2013 used for processing data acquired during the Hartley 2 Encounter from August 2010 to February 2011. The same pipeline was also used to recalibrate Earth and Mars data acquired in 2008 and 2009 for the EPOCh phase of the EPOXI mission as well as EPOXI HRII Lunar Calibrations and Deep Impact HRII/HRIV/MRI/ITS prime mission data. The EPOXI pipeline is based on the one developed for the Deep Impact mission as described by Klaasen, et al. (2008). The document describes the enhancement made to that baseline. For a thoruogh discussion of the calibration process for EPOXI, please refer to the publication, 'EPOXI Instrument Calibration' by Klaasen, et al. (2012)." PUBLICATION_DATE = 2013-01-30 END_OBJECT = PDF_DOCUMENT END