/*          Contents of format file  "COSAC_CALIBRATED_HK.FMT"      */

/*      ...................  DPU  .............................    */ 

 OBJECT       = COLUMN
  NAME        = "P5V_C"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 1
  BYTES       = 8 
  UNIT        = MILLIAMPERE
  FORMAT      = "F8.2"
  DESCRIPTION = "CURRENT +5V LINE"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "M5V_C"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 10
  BYTES       = 8 
  FORMAT      = "F8.2"
  UNIT        = MILLIAMPERE 
  DESCRIPTION = "CURRENT -5V LINE"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "P12V_C"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 19
  BYTES       = 8 
  UNIT        = MILLIAMPERE 
  FORMAT      = "F8.2"
  DESCRIPTION = "CURRENT +12V LINE"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "M12V_C"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 28
  BYTES       = 8 
  UNIT        = MILLIAMPERE 
  FORMAT      = "F8.2"
  DESCRIPTION = "CURRENT -12V LINE"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "SYSTEM_POWER"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 37
  BYTES       = 8 
  UNIT        = WATT
  FORMAT      = "F8.2"
  DESCRIPTION = "SYSTEM POWER "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_ADC_INPUT"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 46
  BYTES       = 8 
  UNIT        = "N/A" 
  FORMAT      = "I8"
  DESCRIPTION = "GC ADC INPUT"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_ADC_INPUT"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 55
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "MS ADC INPUT"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN7_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 64
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 7"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN8_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 73
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 8"
 END_OBJECT   = COLUMN


 OBJECT       = COLUMN
  NAME        = "CHAN9_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 82
  BYTES       = 8 
  UNIT        = "N/A"
  DESCRIPTION = "DPU MUX CHANNEL 9"
  FORMAT      = "I8"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN10_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 91
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 10"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN11_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 100
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 11"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN12_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 109
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 12 "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN13_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 118
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 13"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CHAN14_DPU_MUX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 127
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "DPU MUX CHANNEL 14"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "DPU_VOLTAGE"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 136
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "VOLTAGE DPU"
 END_OBJECT   = COLUMN

/*      ...................  GC  .............................    */    

 OBJECT       = COLUMN
  NAME        = "HE1_PRESSURE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 145
  BYTES       = 10 
  UNIT        = MILLIBAR
  FORMAT      = "I10"
  DESCRIPTION = "Pressure He Tank 1"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HE2_PRESSURE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 156
  BYTES       = 10 
  UNIT        = MILLIBAR
  FORMAT      = "I10"
  DESCRIPTION = "Pressure He Tank 2"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "IONS_MS_PRESSURE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 167
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = "I8"
  DESCRIPTION = "Pressure Ion Source MS"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GCBOARD2_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 176
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature GC-Board2 "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TENAX_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 185
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Tenax"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HE_SEC_PRESSURE"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 194
  BYTES       = 8 
  UNIT        = MILLIBAR
  FORMAT      = "F8.2"
  DESCRIPTION = "Secondary pressure HE)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "VALVE_VOLTAGE"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 203
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "Voltage valve unit"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN1_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 212
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 1)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN2_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 221
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 2"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN3_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 230
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 3"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN4_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 239
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 4"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN5_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 248
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 5"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN6_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 257
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 6"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN7_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 266
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 7"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "COLUMN8_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 275
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Column 8)"
 END_OBJECT   = COLUMN


/*      ...................  MS  .............................    */    


 OBJECT       = COLUMN
  NAME        = "PIPEA_M_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 284
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Pipe a (main)"
 END_OBJECT   = COLUMN


 OBJECT       = COLUMN
  NAME        = "PIPEB_M_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 293
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Pipe b (side)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "OVEN_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 302
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature Oven"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MSEBOX_TEMP"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 311
  BYTES       = 8 
  UNIT        = KELVIN
  FORMAT      = "F8.2"
  DESCRIPTION = "Temperature MS-EBox)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "CALGAS_PRESSURE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 320
  BYTES       = 8 
  UNIT        = "N/A" 
  FORMAT      = "I8"
  DESCRIPTION = "Pressure Calibration Gas"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POSITION"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 329
  BYTES       = 8 
  UNIT        = "N/A" 
  FORMAT      = "I8"
  DESCRIPTION = "Position Tapping Station 
                Open >= 4500, 
                OT (Oberer Totpunkt/Top dead centre) ~ 4710, 
                UT (Unterer Totpunkt/bottom dead centre) ~ 1330)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "EMISSION_CURRENT"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 338
  BYTES       = 8 
  UNIT        = NANOAMPERE
  FORMAT      = "F8.2"
  DESCRIPTION = "Emission current"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV1_DET_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 347
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 1, U detector"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV2_REFL2_4_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 356
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 2, U reflector2_4"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV3_REFL2_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 365
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 3, U reflector 2"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV4_REFL1_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 374
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 4, U reflector 1"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV5_LENSE2_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 383
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 5, U lense 2"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV6_LENSE1_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 392
  BYTES       = 8 
  UNIT        = VOLT 
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 6, U lense 1"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_HV7_G3_V"
  DATA_TYPE   = ASCII_REAL
  START_BYTE  = 401
  BYTES       = 8 
  UNIT        = VOLT
  FORMAT      = "F8.2"
  DESCRIPTION = "MS HV 7, U G3"
 END_OBJECT   = COLUMN

/*      ...................  OS  .............................    */    

 OBJECT       = COLUMN
  NAME        = "REC_CDMS_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 410
  BYTES       = 6 
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Counter for received CDMS messages"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TRANS_CDMS_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 417
  BYTES       = 6 
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Counter for transmit CDMS messages"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "STAT_CDMS_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 424
  BYTES       = 6 
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Counter for CDMS status messages"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "STORED_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 431
  BYTES       = 6 
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Counter for stored messages (TCs)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "RERC_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 438
  BYTES       = 6 
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Counter for RERC messages"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "LAST_SSIF_ERROR"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 445
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Last received SSIF error code)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "LOBT_HIGH"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 453
  BYTES       = 4
  UNIT        = "N/A"
  DESCRIPTION = "LOBT, high in Hexadecimal Format"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "LOBT_LOW"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 460
  BYTES       = 4
  UNIT        = "N/A"
  DESCRIPTION = "LOBT, low in Hexadecimal Format"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "BRAM_POINTER"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 466
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "BackupRAM pointer"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "PHECOPY"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 473
  BYTES       = 6
  UNIT        = "MILLIBAR"
  FORMAT      = "I6"
  DESCRIPTION = "copy of Pressure HE"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_CYCLES"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 480
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "MS cycles"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_CYCLES"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 487
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "GC cycles"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "SYSSTATUS2"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 495
  BYTES       = 4
  UNIT        = "N/A"
  DESCRIPTION = "System Status 2 (Hexadecimal Format) 
       Single Shot Valve: b01 = armed, b11 = fired 
       HK auto collection: 0 = disabled, 1 = enabled 
       MM dump: 0 = idle, 1 = in progress 
       MM auto dump: 0 = disabled, 1 = enabled"  
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "SYSSTATUS1"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 502
  BYTES       = 4
  UNIT        = "N/A"
  DESCRIPTION = "System Status 1  (Hexadecimal Format)
    Configuration valid: bxx1 = TPST, bx1x = MS,  b1xx = GC 
    Continue Flag (not supported) 
    Waiting flag (not supported) 
    System Mode: b000 = idle, b001 = GC, b010=MS, b011=GCMS,
                 b100 = Self test 
    Power Switch: bxxx1=pws1, bxx1x=pws2, bx1xx=pws3 (not used),
                  b1xxx = pws4 
    Mass Memory: 0 = off, 1 = on 
    EEPROM Timestamp: 0 = okay, 1 = mismatch 
    TPST direction changed: 0 = false, 1 = true 
    SD2 ready flag: 0 = false, 1 = true"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "ERROR_MSG"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 508
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Error Message"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_LAST"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 515
  BYTES       = 6
  UNIT        = "N/A"
  FORMAT      = "I6"
  DESCRIPTION = "Last read position of TPST"
 END_OBJECT   = COLUMN