/*          Contents of format file  "COSAC_CONFIG_FM1_8.FMT"          */


 OBJECT                 = COLUMN
   NAME                 = "SD_VERSION_ID"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 2
   BYTES                = 4
   DESCRIPTION          = "Science data stream version ID, 
                           in hexadecimal format.
                           Forversion V1.8 the value is 0x0180"
 END_OBJECT             = COLUMN



 OBJECT                 = COLUMN
   NAME                 = "TIMEREF_ID"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 9
   BYTES                = 19
   DESCRIPTION          = "Used to synchronize LOBT and COBT.
                           The first 8 characters represent the LOBT 
                           in hexadecimal (4 bytes) and the last 8
                           characters represent the COBT (4 bytes).  
                           COBT is the Cosac On-Board Time with a
                           resolution of 1ms."
 END_OBJECT             = COLUMN

/* TC */

 OBJECT                 = COLUMN
   NAME                 = "TC_DATA"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 31
   BYTES                = 39
   DESCRIPTION          = "TC data words in hexadecimal format"
 END_OBJECT             = COLUMN

/* CSIB_CFG */
/*    Configuration data for tapping Station, MS and GC                    */
 
/*   ------  Configuration data for Tapping Station  (30 words) ------   */

 OBJECT       = COLUMN
  NAME        = "TPST_DIR_CONTRL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 73
  BYTES       = 8
  UNIT        = "N/A"
  DESCRIPTION = "TPST: Direct controlling,
                 Possible values : 
                    disabled  
                    enabled"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_INFO"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 84
  BYTES       = 4
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  TPST: Position information
                 0x0000 = LUT , 0xffff = Value"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_ID"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 91
  BYTES       = 20
  UNIT        = "N/A"
  DESCRIPTION = " TPST: Position ID
                  Possible values :
                     Open 
                     Contacts closed 
                     Main Terminal closed 
                     Side Terminal closed
                     Upper position 
                     Lower position"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_VALUE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 114
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) TPST: Position value, 
                                            potentiometer value"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_DIRECTION"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 121
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) TPST: Direction 
                  CS1.D7 = 0000 
                  CS1.D7 = ffff"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_TIME_TO_DRIVE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 128
  BYTES       = 4 
  UNIT        = SECOND
  DESCRIPTION = "(Hexadecimal Format) TPST: Time to drive (sec)" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_START_CAL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 135
  BYTES       = 5 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) TPST: Start calibration
                  Possible values : 
                    False 
                    True" 
 END_OBJECT   = COLUMN


/*   -------------  Configuration data for MS (30 words) ---------------  */

 OBJECT       = COLUMN
  NAME        = "MS_HK_SWEEPING"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 143
  BYTES       = 3 
  UNIT        = "N/A"
  DESCRIPTION = "MS: HK sweeping 
                 Possible values : 
                    yes 
                    no" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_ACCUMULATE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 149
  BYTES       = 3 
  UNIT        = "N/A"
  DESCRIPTION = "MS: Accumulate parameter ; possible values :
                     yes
                     no" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_CATHODE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 154
  BYTES       = 1 
  UNIT        = "N/A"
  DESCRIPTION = "MS: Cathode number to be selected" 
  FORMAT      = I1
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_EMI_CURRENT"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 157
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Emission current" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_DET_VOLT"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 164
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Detector voltage" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_RESOL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 171
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = " MS: Resolution possible values :
                      low
                      high " 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_FREQUENCY"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 177
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "MS: Frequency" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_RUN CAL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 187
  BYTES       = 5 
  UNIT        = "N/A"
  DESCRIPTION = "MS: Run calibration 
                 Possible values : 
                    False 
                    True" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_SNIFFING_MODE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 195
  BYTES       = 8 
  UNIT        = "N/A"
  DESCRIPTION = "MS: Sniffing mode
                 Possible values : 
                    disabled 
                    enabled" 
 END_OBJECT   = COLUMN


/*   -------------  Configuration data for GC (30 words) -------------   */


 OBJECT       = COLUMN
  NAME        = "GC_HK_SWEEPING"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 206
  BYTES       = 3 
  UNIT        = "N/A"
  DESCRIPTION = "GC: HK sweeping
                  Possible values : 
                    yes 
                    no" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_CONTINUE_FLAG"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 212
  BYTES       = 5 
  UNIT        = "N/A"
  DESCRIPTION = "GC: continue flag ; Possible values : 
                    False 
                    True" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_DUR_MEASURE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 219
  BYTES       = 2 
  UNIT        = "N/A"
  FORMAT      = I2 
  DESCRIPTION = "GC: Duration of measurement
                 This is an index pointing into a look-up table 
                 holding the following values:
                    1  : 1,12 min
                    2  : 2,23 min
                    4  : 4,47 min
                    8  : 8,95 min
                    16 : 17,89 min

                 Note that any combination of the above values is possible!
                    01010 : 8,95 + 2,23 min
                    10101 : 17,89 + 4,47 + 1,12 min" 
 END_OBJECT   = COLUMN


 OBJECT       = COLUMN
  NAME        = "GC_HELIUM_TANK"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 223
  BYTES       = 6 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Helium tank selected 
                 Possible values : 
                    Tank 1 
                    Tank 2" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_DUR_INJEC"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 231
  BYTES       = 8 
  UNIT        = MILLISECOND
  FORMAT      = I8
  DESCRIPTION = "GC: Duration of injection (msec)" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_SAMPLE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 241
  BYTES       = 15 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Sample
                 Possible values :
                    Calibration gas 
                    Oven 
                    Tenax" 
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_CHANNEL_1"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 258
  BYTES       = 1 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Column selection for Channel 1 
                   Column #1  0x000i (0 <= i <= 7)
                   Column #2  0x00i0 (0 <= i <= 7)
                   Column #3  0x0i00 (0 <= i <= 7)
                   Column #4  0xi000 (0 <= i <= 7)"
 END_OBJECT   = COLUMN
 
 OBJECT       = COLUMN
  NAME        = "GC_CHANNEL_2"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 260
  BYTES       = 1 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Column selection for Channel 2 
                     Column #1  0x000i (0 <= i <= 7)
                     Column #2  0x00i0 (0 <= i <= 7)
                     Column #3  0x0i00 (0 <= i <= 7)
                     Column #4  0xi000 (0 <= i <= 7)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_CHANNEL_3"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 262
  BYTES       = 1 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Column selection for Channel 3 
                   Column #1  0x000i (0 <= i <= 7)
                   Column #2  0x00i0 (0 <= i <= 7)
                   Column #3  0x0i00 (0 <= i <= 7)
                   Column #4  0xi000 (0 <= i <= 7)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_CHANNEL_4"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 264
  BYTES       = 1 
  UNIT        = "N/A"
  DESCRIPTION = "GC: Column selection for Channel 4 
                    Column #1  0x000i (0 <= i <= 7)
                    Column #2  0x00i0 (0 <= i <= 7)
                    Column #3  0x0i00 (0 <= i <= 7)
                    Column #4  0xi000 (0 <= i <= 7)"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_COL_HEAD_PRESS"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 267
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) GC: Column head pressure
                 0x0000 <= x <= 0x00ff" 
 END_OBJECT   = COLUMN


/* CSIB_PAR */
/*       Device parameters and experiment parameters for MS and GC          */

/*   ---------------     Device parameters   (27 words)   ---------------  */

 OBJECT       = COLUMN
  NAME        = "TPST_POS_OPEN"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 273
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Open"
 END_OBJECT   = COLUMN


 OBJECT       = COLUMN
  NAME        = "TPST_POS_CONT_CLOS"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 282
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Contacts Closed"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_MAIN_TERM_CLOS"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 291
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Main Terminal Closed"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_SIDE_TERM_CLOS"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 300
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Side Terminal Closed"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_UPPER"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 309
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Upper"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_POS_LOWER"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 318
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "TPST: Position Lower"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_BACKUP_RAM"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 328
  BYTES       = 3
  UNIT        = "N/A"
  DESCRIPTION = "TPST: Use of Backup Ram ; possible values :
                        yes
                        no"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_IGN_SD2 STAT"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 334
  BYTES       = 3
  UNIT        = "N/A"
  DESCRIPTION = "TPST: Ignore SD2 Status  ; possible values :
                        yes
                        no"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_TIMEOUT_VALUE"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 339
  BYTES       = 8 
  UNIT        = "MILLISECOND"
  FORMAT      = I8
  DESCRIPTION = "TPST: Timeout Value"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TPST_CREATE_REPORT"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 349
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  TPST: Create Report"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_0"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 356
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[0]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_1"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 363
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[1]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_2"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 370
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[2]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_3"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 377
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[3]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_4"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 384
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[4]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_5"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 391
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[5]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_6"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 398
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[6]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "TEMPERATURE_7"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 405
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) Temperature[7]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_0"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 412
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[0]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_1"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 419
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[1]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_2"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 426
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[2]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_3"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 433
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[3]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_4"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 440
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[4]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_5"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 447
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[5]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_6"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 454
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[6]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "HEATING_TIME_7"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 461
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format)  Heating Time[7]"
 END_OBJECT   = COLUMN


/*   ---------------  Experiment parameters MS    (18 words) -----------  */

 OBJECT       = COLUMN
  NAME        = "MS_DURATION"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 468
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Duration
                  Basically, it is a timing information, but it varies 
                  according to the programmed frequency:
                      Bit        1 kHz         4 kHz
                       3          67,1 s       16,8 s
                       2          33,5 s        8,4 s
                       1          16,8 s        4,19 s
                       0          8,4 s         2,1 s
                  Please note: any combination is possible:
                   0x7 at 1kHz = 33,5 + 16,8 + 8,4 s 
                   0x7 at 4kHz = 8,4 + 4,19 + 2,1 s"

 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_USE_AUTO_CAL_VAL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 475
  BYTES       = 5 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Use auto calibration values
                   possible values :
                        True
                        False"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_PRESSURE_CAL_GAS"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 482
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "(Hexadecimal Format) MS: Pressure calibration gas"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_MODE"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 492
  BYTES       = 6 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Mode  ; possible values :
                        Single
                        Multi"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_GAS_FLOW_DELAY"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 501
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Gas Flow Delay"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_U_0]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 508
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: U[0]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_U_1]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 515
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: U[1]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_U_2]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 522
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: U[2]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_U_3]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 529
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: U[3]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_0]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 536
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[0]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_1]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 543
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[1]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_2]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 550
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[2]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_3]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 557
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[3]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_4]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 564
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[4]"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_5]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 571
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[5]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_T_6]"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 578
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: T[6]
                  Counter with 31,25 ms/cnt "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_DET_START_DEL"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 585
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Detector Start Delay
                  This is an integer with the following  bit allocation: 
                      Bit          Sampling time delay in microseconds
                       3             256 
                       2             128 
                       1             64 
                       0             32 "
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "MS_WORDS_SC_DATA"
  DATA_TYPE   = CHARACTER
  START_BYTE  = 592
  BYTES       = 4 
  UNIT        = "N/A"
  DESCRIPTION = "(Hexadecimal Format) MS: Words to copy from Science Data"
 END_OBJECT   = COLUMN


/* ---------------     Experiment parameters GC (10 words) -------------  */


 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_0"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 598
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 0"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_1"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 607
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 1"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_2"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 616
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 2"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_3"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 625
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 3"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_4"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 634
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 4"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_5"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 643
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 5"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_6"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 652
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "Temperature Column 6"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TEMP_COL_7"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 661
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Temperature Column 7"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_WORDS_SC_DATA"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 670
  BYTES       = 8 
  UNIT        = "N/A"
  FORMAT      = I8
  DESCRIPTION = "GC: Words to copy from Science Data"
 END_OBJECT   = COLUMN

 OBJECT       = COLUMN
  NAME        = "GC_TIME_TENAX"
  DATA_TYPE   = ASCII_INTEGER
  START_BYTE  = 679
  BYTES       = 8 
  UNIT        = SECOND
  FORMAT      = I8
  DESCRIPTION = "GC: Time to heat Tenax (sec)"
 END_OBJECT   = COLUMN