OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 DESCRIPTION = "This column represents the UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MUPUS_TIME" DATA_TYPE = CHARACTER START_BYTE = 26 BYTES = 8 FORMAT = "A8" DESCRIPTION = "MUPUS On Board Time represented as a 32-bit integer (in hexadecimal format) with 1 millisecond resolution. It counts the time since the MUPUS boot and overruns after 49.7 days (2^32 milliseconds)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PEN_DATA_FLAG" DATA_TYPE = CHARACTER START_BYTE = 37 BYTES = 3 FORMAT = "A3" UNIT = "N/A" DESCRIPTION = "Availability of PEN data. Possible values are YES or NO" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_MODE" DATA_TYPE = CHARACTER START_BYTE = 43 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Possible values are: LONGTERM TEM THC MAPPER CMAPPER " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_A" DATA_TYPE = CHARACTER START_BYTE = 54 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper thermopile channel A" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_B" DATA_TYPE = CHARACTER START_BYTE = 61 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper thermopile channel B" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_C" DATA_TYPE = CHARACTER START_BYTE = 68 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper thermopile channel C" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_D" DATA_TYPE = CHARACTER START_BYTE = 75 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper thermopile channel D" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_BLACKBODY" DATA_TYPE = CHARACTER START_BYTE = 82 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper blackbody Pt-100" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_A_REF" DATA_TYPE = CHARACTER START_BYTE = 89 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper reference channel A Pt-1000" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_B_REF" DATA_TYPE = CHARACTER START_BYTE = 96 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper reference channel B Pt-1000" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_C_REF" DATA_TYPE = CHARACTER START_BYTE = 103 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper reference channel C Pt-1000" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_D_REF" DATA_TYPE = CHARACTER START_BYTE = 110 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Thermal mapper reference channel D Pt-1000" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_ANCT1" DATA_TYPE = CHARACTER START_BYTE = 117 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Anchor 1 temperature sensor Pt-100" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_ANCT2" DATA_TYPE = CHARACTER START_BYTE = 124 BYTES = 4 FORMAT = "A4" UNIT = "ADC" DESCRIPTION = "Anchor 2 temperature sensor Pt-100" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POWER_STATUS_FLAGS" DATA_TYPE = CHARACTER START_BYTE = 131 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Power Status Flags" END_OBJECT = COLUMN