OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 DESCRIPTION = "This column represents the UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MUPUS_TIME" DATA_TYPE = CHARACTER START_BYTE = 26 BYTES = 8 FORMAT = "A8" DESCRIPTION = "MUPUS On Board Time represented as a 32-bit integer (in hexadecimal format) with 1 millisecond resolution. It counts the time since the MUPUS boot and overruns after 49.7 days (2^32 milliseconds)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PEN_DATA_FLAG" DATA_TYPE = CHARACTER START_BYTE = 37 BYTES = 3 FORMAT = "A3" UNIT = "N/A" DESCRIPTION = "Availability of PEN data. Possible values are YES or NO" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_MODE" DATA_TYPE = CHARACTER START_BYTE = 43 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Possible values are: LONGTERM TEM THC MAPPER CMAPPER " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_A" DATA_TYPE = ASCII_REAL START_BYTE = 53 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper thermopile channel A ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_B" DATA_TYPE = ASCII_REAL START_BYTE = 61 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper thermopile channel B ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_C" DATA_TYPE = ASCII_REAL START_BYTE = 69 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper thermopile channel C ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CHANNEL_D" DATA_TYPE = ASCII_REAL START_BYTE = 77 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper thermopile channel D ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_BLACKBODY" DATA_TYPE = ASCII_REAL START_BYTE = 85 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper blackbody Pt-100 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_A_REF" DATA_TYPE = ASCII_REAL START_BYTE = 93 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper reference channel A Pt-1000 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_B_REF" DATA_TYPE = ASCII_REAL START_BYTE = 101 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper reference channel B Pt-1000 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_C_REF" DATA_TYPE = ASCII_REAL START_BYTE = 109 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper reference channel C Pt-1000 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_CH_D_REF" DATA_TYPE = ASCII_REAL START_BYTE = 117 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Thermal mapper reference channel D Pt-1000 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_ANCT1" DATA_TYPE = ASCII_REAL START_BYTE = 125 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Anchor 1 temperature sensor Pt-100 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TM_ANCT2" DATA_TYPE = ASCII_REAL START_BYTE = 133 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "Anchor 2 temperature sensor Pt-100 ADC readings converted to KELVIN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POWER_STATUS_FLAGS" DATA_TYPE = CHARACTER START_BYTE = 142 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Power Status Flags The possible values are 1: true 0: false The 12 flags are the following. Heater Low Power Mode Nominal Power Mode Calibration Mode Last heat time > 1h40min TM powered Calibration mode (sub-mode) refused PEN_EL Heater Mode Flag Mean Flag Last Heat Time > 1h PEN powered" END_OBJECT = COLUMN