/*     Contents of format file  "PTOLEMY_SN2.FMT"  (Uncalibrated HK sensor) */


OBJECT                  = COLUMN
   NAME                 = "TIME_CODE"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 2
   BYTES                = 17
   DESCRIPTION          = "Time code at which sensor acquisition initiated
                           in lander On Board Time; LOBT IS REPRESENTED AS :
                           Reset number (integer starting at 1) / seconds.
                           Reset number 1 starts at 2003-01-01T00:00:00 UTC
                           The time resolution is 1/65536 s"
 END_OBJECT             = COLUMN

OBJECT                  = COLUMN
   NAME                 = "UTC"
   DATA_TYPE            = TIME
   START_BYTE           = 21
   BYTES                = 23
   DESCRIPTION          = "Date at which sensor acquisition initiated 
                           in On-Ground time (UTC)
                           Format : YYYY-MM-DDThh:mm:ss.sss"
 END_OBJECT             = COLUMN  

 OBJECT                 = COLUMN
   NAME                 = "SENSOR_REPORT_TYPE"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 46
   BYTES                = 7
   UNIT                 = "N/A"
   DESCRIPTION          = "The type of the sensor report. 
                           Can take the values:
                              Concise
                              Summary"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "OP_MODE"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 55
   BYTES                = 3
   UNIT                 = "N/A"
   FORMAT               = "I3"
   DESCRIPTION          = "Ptolemy operating mode.
                           The possible values are:
                           0       Standby mode
                           255     Safe mode
                           1 to 16 Science modes
                           For science modes the sequence table 
                           that was execued is given in the logbook "
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TC_MODE"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 59
   BYTES                = 3
   UNIT                 = "N/A"
   FORMAT               = "I3"
   DESCRIPTION          = "TC mode (zero in safe mode)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "LINE_NUMBER"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 63
   BYTES                = 6
   UNIT                 = "N/A"
   FORMAT               = "I6"
   DESCRIPTION          = "Line number for current mode event (zero in safe
                           mode)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "ST_TC_RQD"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 70
   BYTES                = 6 
   UNIT                 = "N/A"
   FORMAT               = "I6"
   DESCRIPTION          = "Number of stored TCs requested (zero in safe mode)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "ST_TC_RCVD"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 77
   BYTES                = 6
   UNIT                 = "N/A"
   FORMAT               = "I6"
   DESCRIPTION          = "Number of stored TCs received (zero in safe mode)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TC_TYPE"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 84
   BYTES                = 3
   UNIT                 = "N/A"
   FORMAT               = "I3"
   DESCRIPTION          = "Type of last received TC (zero if no TC received)"
END_OBJECT              = COLUMN  

OBJECT                  = COLUMN
   NAME                 = "TC_SUBTYPE"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 88
   BYTES                = 3
   UNIT                 = "N/A"
   FORMAT               = "I3"
   DESCRIPTION          = "Subtype of last TC received (zero if no TC 
                           received)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR1"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 92
   BYTES                = 8 
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R1 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR2"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 101
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R2 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR4"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 110
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R4 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR5"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 119
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R5 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR6"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 128
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R6 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR7"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 137
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R7 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR8"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 146
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R8 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR9"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 155
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R9 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR13"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 164
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R13 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR15"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 173
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "reactor R15 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TLV1"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 182
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Lindau valve 1 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TLV2"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 191
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Lindau valve 2 thermocouple reading" 
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TLV5"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 200
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Lindau valve 5 thermocouple reading"
END_OBJECT              = COLUMN 

OBJECT                  = COLUMN
   NAME                 = "TLV6"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 209
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Lindau valve 6 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TLV7"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 218
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Lindau valve 7 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TGC"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 227
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Thermocouple reading for Gas Chromatograph columns"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TENCA"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 236
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Thermal Enclosure A thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TENCB"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 245
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Thermal Enclosure B thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TION"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 254
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Ion Trap thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TOVEN"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 263
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Oven thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TPIPE"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 272
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Pipe heater thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "PG1"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 281
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Pressure of Helium as indicated by sensor G1"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "PG2"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 290
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Pressure of Helium as indicated by sensor G2"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "PG3"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 299
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Absolute Pressure as indicated by sensor G3"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "PG4"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 308
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Pressure of Helium as indicated by sensor G4"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "PG5"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 317
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Differential Pressure as indicated by sensor G5"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "TR14"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 326
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Reactor R14 thermocouple reading"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "AD590"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 335
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Reference junction thermometer (AD590)"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "VDS"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 344
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Docking station potentiometer"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "INT"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 353
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Nanotip drive current"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "VDET"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 362
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Detector Bias"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "V5V"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 371
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "5V voltage monitor"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "V28V"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 380
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "28V voltage monitor"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "I5V"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 389
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Current monitored on 5 volt rail"
END_OBJECT              = COLUMN

OBJECT                  = COLUMN
   NAME                 = "I28V"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 398
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "Current monitored on 28V bus"
END_OBJECT              = COLUMN 

OBJECT                  = COLUMN
   NAME                 = "VRFCAL"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 407
   BYTES                = 8
   UNIT                 = VOLT
   FORMAT               = "F8.4"
   DESCRIPTION          = "RF calibration"
END_OBJECT              = COLUMN