/* Contents of format file "PTOLEMY_SN2.FMT" (Uncalibrated HK sensor) */ OBJECT = COLUMN NAME = "TIME_CODE" DATA_TYPE = CHARACTER START_BYTE = 2 BYTES = 17 DESCRIPTION = "Time code at which sensor acquisition initiated in lander On Board Time; LOBT IS REPRESENTED AS : Reset number (integer starting at 1) / seconds. Reset number 1 starts at 2003-01-01T00:00:00 UTC The time resolution is 1/65536 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 21 BYTES = 23 DESCRIPTION = "Date at which sensor acquisition initiated in On-Ground time (UTC) Format : YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SENSOR_REPORT_TYPE" DATA_TYPE = CHARACTER START_BYTE = 46 BYTES = 7 UNIT = "N/A" DESCRIPTION = "The type of the sensor report. Can take the values: Concise Summary" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_MODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "Ptolemy operating mode" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_MODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 59 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "TC mode (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINE_NUMBER" DATA_TYPE = ASCII_INTEGER START_BYTE = 63 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Line number for current mode event (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ST_TC_RQD" DATA_TYPE = ASCII_INTEGER START_BYTE = 70 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Number of stored TCs requested (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ST_TC_RCVD" DATA_TYPE = ASCII_INTEGER START_BYTE = 77 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Number of stored TCs received (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_TYPE" DATA_TYPE = ASCII_INTEGER START_BYTE = 84 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "Type of last received TC (zero if no TC received)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_SUBTYPE" DATA_TYPE = ASCII_INTEGER START_BYTE = 88 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "Subtype of last TC received (zero if no TC received)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR1" DATA_TYPE = ASCII_REAL START_BYTE = 92 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R1 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR2" DATA_TYPE = ASCII_REAL START_BYTE = 101 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R2 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR4" DATA_TYPE = ASCII_REAL START_BYTE = 110 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R4 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR5" DATA_TYPE = ASCII_REAL START_BYTE = 119 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R5 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR6" DATA_TYPE = ASCII_REAL START_BYTE = 128 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R6 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR7" DATA_TYPE = ASCII_REAL START_BYTE = 137 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R7 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR8" DATA_TYPE = ASCII_REAL START_BYTE = 146 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R8 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR9" DATA_TYPE = ASCII_REAL START_BYTE = 155 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R9 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR13" DATA_TYPE = ASCII_REAL START_BYTE = 164 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R13 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR15" DATA_TYPE = ASCII_REAL START_BYTE = 173 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "reactor R15 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV1" DATA_TYPE = ASCII_REAL START_BYTE = 182 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Lindau valve 1 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV2" DATA_TYPE = ASCII_REAL START_BYTE = 191 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Lindau valve 2 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV5" DATA_TYPE = ASCII_REAL START_BYTE = 200 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Lindau valve 5 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV6" DATA_TYPE = ASCII_REAL START_BYTE = 209 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Lindau valve 6 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV7" DATA_TYPE = ASCII_REAL START_BYTE = 218 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Lindau valve 7 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TGC" DATA_TYPE = ASCII_REAL START_BYTE = 227 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Thermocouple reading for Gas Chromatograph columns" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TENCA" DATA_TYPE = ASCII_REAL START_BYTE = 236 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Thermal Enclosure A thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TENCB" DATA_TYPE = ASCII_REAL START_BYTE = 245 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Thermal Enclosure B thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TION" DATA_TYPE = ASCII_REAL START_BYTE = 254 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Ion Trap thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TOVEN" DATA_TYPE = ASCII_REAL START_BYTE = 263 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Oven thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPIPE" DATA_TYPE = ASCII_REAL START_BYTE = 272 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Pipe heater thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG1" DATA_TYPE = ASCII_REAL START_BYTE = 281 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Pressure of Helium as indicated by sensor G1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG2" DATA_TYPE = ASCII_REAL START_BYTE = 290 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Pressure of Helium as indicated by sensor G2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG3" DATA_TYPE = ASCII_REAL START_BYTE = 299 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Absolute Pressure as indicated by sensor G3" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG4" DATA_TYPE = ASCII_REAL START_BYTE = 308 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Pressure of Helium as indicated by sensor G4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG5" DATA_TYPE = ASCII_REAL START_BYTE = 317 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Differential Pressure as indicated by sensor G5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR14" DATA_TYPE = ASCII_REAL START_BYTE = 326 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Reactor R14 thermocouple reading" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AD590" DATA_TYPE = ASCII_REAL START_BYTE = 335 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Reference junction thermometer (AD590)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VDS" DATA_TYPE = ASCII_REAL START_BYTE = 344 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Docking station potentiometer" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "INT" DATA_TYPE = ASCII_REAL START_BYTE = 353 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Nanotip drive current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VDET" DATA_TYPE = ASCII_REAL START_BYTE = 362 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Detector Bias" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "V5V" DATA_TYPE = ASCII_REAL START_BYTE = 371 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "5V voltage monitor" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "V28V" DATA_TYPE = ASCII_REAL START_BYTE = 380 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "28V voltage monitor" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I5V" DATA_TYPE = ASCII_REAL START_BYTE = 389 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Current monitored on 5 volt rail" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I28V" DATA_TYPE = ASCII_REAL START_BYTE = 398 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "Current monitored on 28V bus" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VRFCAL" DATA_TYPE = ASCII_REAL START_BYTE = 407 BYTES = 8 UNIT = VOLT FORMAT = "F8.4" DESCRIPTION = "RF calibration" END_OBJECT = COLUMN