/* Contents of format file "PTOLEMY_SN3.FMT" (Calibrated HK SENSOR) */ OBJECT = COLUMN NAME = "TIME_CODE" DATA_TYPE = CHARACTER START_BYTE = 2 BYTES = 17 FORMAT = "A17" DESCRIPTION = "Time code at which sensor acquisition initiated in lander On Board Time; LOBT IS REPRESENTED AS : Reset number (integer starting at 1) / seconds. Reset number 1 starts at 2003-01-01T00:00:00 UTC The time resolution is 1/65536 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 21 BYTES = 23 DESCRIPTION = "Date at which sensor acquisition initiated in On-Ground time (UTC) Format : YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SENSOR REPORT_TYPE" DATA_TYPE = CHARACTER START_BYTE = 46 BYTES = 7 FORMAT = "A7" DESCRIPTION = "The type of the sensor report. Can take the values: Concise Summary" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_MODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 3 FORMAT = "I3" DESCRIPTION = "Ptolemy operating mode. The possible values are: 0 Standby mode 255 Safe mode 1 to 16 Science modes For science modes the sequence table that was execued is given in the logbook " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_MODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 59 BYTES = 3 FORMAT = "I3" DESCRIPTION = "TC mode (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINE_NUMBER" DATA_TYPE = ASCII_INTEGER START_BYTE = 63 BYTES = 6 FORMAT = "I6" DESCRIPTION = " Line number for current mode event (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ST_TC_RQD" DATA_TYPE = ASCII_INTEGER START_BYTE = 70 BYTES = 6 FORMAT = "I6" DESCRIPTION = "Number of stored TCs requested (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ST_TC_RCVD" DATA_TYPE = ASCII_INTEGER START_BYTE = 77 BYTES = 6 FORMAT = "I6" DESCRIPTION = " Number of stored TCs received (zero in safe mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_TYPE" DATA_TYPE = ASCII_INTEGER START_BYTE = 84 BYTES = 3 FORMAT = "I3" DESCRIPTION = "Type of last received TC (zero if no TC received)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TC_SUBTYPE" DATA_TYPE = ASCII_INTEGER START_BYTE = 88 BYTES = 3 FORMAT = "I3" DESCRIPTION = " Subtype of last TC received (zero if no TC received)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR1" DATA_TYPE = ASCII_INTEGER START_BYTE = 92 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R1 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR2" DATA_TYPE = ASCII_INTEGER START_BYTE = 97 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R2 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR4" DATA_TYPE = ASCII_INTEGER START_BYTE = 102 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R4 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR5" DATA_TYPE = ASCII_INTEGER START_BYTE = 107 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R5 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR6" DATA_TYPE = ASCII_INTEGER START_BYTE = 112 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R6 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR7" DATA_TYPE = ASCII_INTEGER START_BYTE = 117 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R7 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR8" DATA_TYPE = ASCII_INTEGER START_BYTE = 122 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R8 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR9" DATA_TYPE = ASCII_INTEGER START_BYTE = 127 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R9 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR13" DATA_TYPE = ASCII_INTEGER START_BYTE = 132 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R13 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR15" DATA_TYPE = ASCII_INTEGER START_BYTE = 137 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " reactor R15 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV1" DATA_TYPE = ASCII_INTEGER START_BYTE = 142 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Lindau valve 1 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV2" DATA_TYPE = ASCII_INTEGER START_BYTE = 146 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Lindau valve 2 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV5" DATA_TYPE = ASCII_INTEGER START_BYTE = 150 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Lindau valve 5 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV6" DATA_TYPE = ASCII_INTEGER START_BYTE = 154 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Lindau valve 6 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TLV7" DATA_TYPE = ASCII_INTEGER START_BYTE = 158 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Lindau valve 7 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TGC" DATA_TYPE = ASCII_INTEGER START_BYTE = 162 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = "Thermocouple reading for Gas Chromatograph columns" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TENCA" DATA_TYPE = ASCII_INTEGER START_BYTE = 166 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Thermal Enclosure A thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TENCB" DATA_TYPE = ASCII_INTEGER START_BYTE = 170 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = "Thermal Enclosure B thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TION" DATA_TYPE = ASCII_INTEGER START_BYTE = 174 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = "Ion Trap thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TOVEN" DATA_TYPE = ASCII_INTEGER START_BYTE = 178 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Oven thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPIPE" DATA_TYPE = ASCII_INTEGER START_BYTE = 182 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Pipe heater thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG1" DATA_TYPE = ASCII_INTEGER START_BYTE = 186 BYTES = 6 UNIT = PASCAL FORMAT = "I6" MISSING_CONSTANT = 999999 DESCRIPTION = "Pressure of Helium as indicated by sensor G1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG2" DATA_TYPE = ASCII_INTEGER START_BYTE = 193 BYTES = 6 UNIT = PASCAL FORMAT = "I6" MISSING_CONSTANT = 999999 DESCRIPTION = "Pressure of Helium as indicated by sensor G2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG3" DATA_TYPE = ASCII_INTEGER START_BYTE = 200 BYTES = 6 UNIT = PASCAL FORMAT = "I6" MISSING_CONSTANT = 999999 DESCRIPTION = " Pressure of Helium as indicated by sensor G3 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG4" DATA_TYPE = ASCII_INTEGER START_BYTE = 207 BYTES = 6 UNIT = PASCAL FORMAT = "I6" MISSING_CONSTANT = 999999 DESCRIPTION = " Pressure of Helium as indicated by sensor G4 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PG5" DATA_TYPE = ASCII_INTEGER START_BYTE = 214 BYTES = 6 UNIT = PASCAL FORMAT = "I6" MISSING_CONSTANT = 999999 DESCRIPTION = " Pressure of Helium as indicated by sensor G5 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TR14" DATA_TYPE = ASCII_INTEGER START_BYTE = 221 BYTES = 4 UNIT = KELVIN FORMAT = "I4" MISSING_CONSTANT = 9999 DESCRIPTION = " Reactor R14 thermocouple reading " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AD590" DATA_TYPE = ASCII_INTEGER START_BYTE = 226 BYTES = 3 UNIT = KELVIN FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = " Reference junction thermometer (AD590) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VDS" DATA_TYPE = ASCII_REAL START_BYTE = 230 BYTES = 5 UNIT = MILLIMETER FORMAT = "F5.2" DESCRIPTION = " Docking station potentiometer " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "INT" DATA_TYPE = ASCII_INTEGER START_BYTE = 236 BYTES = 4 UNIT = MICROAMPERE FORMAT = "I4" DESCRIPTION = " Nanotip drive current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VDET" DATA_TYPE = ASCII_INTEGER START_BYTE = 241 BYTES = 4 UNIT = VOLT FORMAT = "I4" DESCRIPTION = " Detector Bias " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "V5V" DATA_TYPE = ASCII_REAL START_BYTE = 246 BYTES = 4 UNIT = VOLT FORMAT = "F4.2" DESCRIPTION = " 5V voltage monitor " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "V28V" DATA_TYPE = ASCII_REAL START_BYTE = 251 BYTES = 4 UNIT = VOLT FORMAT = "F4.1" DESCRIPTION = " 28V voltage monitor " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I5V" DATA_TYPE = ASCII_INTEGER START_BYTE = 256 BYTES = 4 UNIT = MILLIAMPERE FORMAT = "I4" DESCRIPTION = " Current monitored on 5 volt rail " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I28V" DATA_TYPE = ASCII_INTEGER START_BYTE = 261 BYTES = 4 UNIT = MILLIAMPERE FORMAT = "I4" DESCRIPTION = " Current monitored on 28V bus " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VRFCAL" DATA_TYPE = ASCII_INTEGER START_BYTE = 266 BYTES = 3 UNIT = VOLT FORMAT = "I3" DESCRIPTION = " RF calibration " END_OBJECT = COLUMN