/* FILE_CONTENTS           = DIM Sensor Test data */
/*                           Flight software FM1, FM2, FM3, CODMAC level 2 */
/* FILE_NAME               = DIM_ST.FMT */
/* REVISION_NOTE           = H. Krueger, version 1, 2015-07-30 */
/*                         = H. Krueger, version 2, 2015-09-10 */
/*                         = A. Hirn, version 3, 2015-11-20 */

OBJECT                     = COLUMN
    NAME                   = "UTC"
    DATA_TYPE              = TIME
    START_BYTE             = 1
    BYTES                  = 23
    DESCRIPTION            = "Measurement start time (UTC in PDS standard
                              format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SESAME_LOCAL_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 25
    BYTES                  = 15
    FORMAT                 = "I15"
    DESCRIPTION            = "Measurement start time. SESAME local time
                              (SLT) runs with a resolution of 1/32 seconds.
                              SLT represents the least significant 32 bits
                              of LOBT. The most significant 5 bits are in
                              CDMS RSST (see SESAME Ready Message)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "DIRECTION"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 42
    BYTES                  = 1 
    FORMAT                 = "A1"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9"
DESCRIPTION                = "DIM sensor direction, can be X, Y or Z. 
                              Echoed command parameter." 
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "MARGIN"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 45
    BYTES                  = 2
    FORMAT                 = "I2"
    UNIT                   = "DECIBEL"
    MISSING_CONSTANT       = 99
    DESCRIPTION            = "DIM noise test margin"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "ERROR_CODE"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 49
    BYTES                  = 2
    FORMAT                 = "A2"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "99"
    DESCRIPTION            = "DIM sensor test error code,
                              2 hexadecimal characters"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "AVG_MV"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 53
    BYTES                  = 4
    FORMAT                 = "I4"
    UNIT                   = "MILLIVOLT"
    MISSING_CONSTANT       = 9999
    DESCRIPTION            = "DIM Average signal in mV"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "PEAK_MV"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 58
    BYTES                  = 4
    FORMAT                 = "I4"
    UNIT                   = "MILLIVOLT"
    MISSING_CONSTANT       = 9999
    DESCRIPTION            = "DIM Signal Peak voltage in mV"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "COUNTS"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 63
    BYTES                  = 6
    FORMAT                 = "I6"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 999999
    DESCRIPTION            = "DIM Timer counts"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "AVG_DB"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 70
    BYTES                  = 2
    FORMAT                 = "I2"
    UNIT                   = "DECIBEL"
    MISSING_CONSTANT       = 99
    DESCRIPTION            = "DIM Average signal in dB"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "PEAK_DB"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 73
    BYTES                  = 2
    FORMAT                 = "I2"
    UNIT                   = "DECIBEL"
    MISSING_CONSTANT       = 99
    DESCRIPTION            = "DIM Signal Peak voltage in dB"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TIME_DB"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 76
    BYTES                  = 2
    FORMAT                 = "I2"
    UNIT                   = "DECIBEL"
    MISSING_CONSTANT       = 99
    DESCRIPTION            = "DIM impact time in compressed format"
END_OBJECT                 = COLUMN