/* PP Health Check, version 2, 2015-11-11 */

OBJECT                 = COLUMN
    NAME               = "SESAME_SEQ_ID"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 1
    BYTES              = 6
    UNIT               = "N/A"
    FORMAT             = "I6"
    DESCRIPTION        = "Sequence ID in the current data file"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
  NAME                 = "UTC"
  DATA_TYPE            = TIME
  START_BYTE           = 8
  BYTES                = 23
  DESCRIPTION          = "Measurement start time (UTC in PDS standard
                          format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "SESAME_LOCAL_TIME"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 32
    BYTES              = 15
    FORMAT             = "I15"
    DESCRIPTION        = "Measurement start time. SESAME local time
                          (SLT) runs with a resolution of 1/32 seconds.
                          SLT represents the least significant 32 bits
                          of LOBT. The most significant 5 bits are in
                          CDMS RSST (see SESAME Ready Message)"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "LP_VALUE"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 48
    BYTES              = 5
    UNIT               = "N/A"
    FORMAT             = "I5"
    DESCRIPTION        = "Result count of Langmuir probe measurement "
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "ADC_OFFSET"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 54
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Should be close to 128
                          (128 represents zero with bipolar ADC)"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "-2.5V REF"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 58
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "-2.5V REF and +2.5V REF should be nearly
                          symmetrical to ADC offset"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "+2.5V_REF"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 62
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "-2.5V REF and +2.5V REF should be nearly
                          symmetrical to ADC offset"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "DELTA"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 66
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Differential value RX2 - RX1"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "LEG+Y_RX1"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 70
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Direct voltage from receiver 1 at +Y leg"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "LEG-Y_RX2"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 74
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Direct voltage from receiver 2 at -Y leg"
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "LEG+X_TX1"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 78
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Transmitter current at electrode 1.
                          No voltage applied.
                          Should be close to ADC offset."
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "MUPUS_PEN_TX2"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 82
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Transmitter current at electrode 2.
                          No voltage applied.
                          Should be close to ADC offset."
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "APXS_TX3"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 86
    BYTES              = 3
    UNIT               = "N/A"
    FORMAT             = "I3"
    DESCRIPTION        = "Transmitter current at electrode 3.
                          No volatge applied.
                          Should be close to ADC offset."
END_OBJECT             = COLUMN

OBJECT                 = COLUMN
    NAME               = "ERROR_CODE"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 90
    BYTES              = 8
    UNIT               = "N/A"
    MISSING_CONSTANT   = 16#0000#
    DESCRIPTION        = "Hex value as 16#xxxx#. The  possible values are:
                          8001  Invalid register address.
                          8002  Error verifying register write.
                          8004  Error accessing power register.
                          8008  MUX setting not allowed.
                          8010  Error accessing PP RAM.
                          8020  Tried to start measurement but a measurement
                                is already running.
                          0040  Error during writing to instrument.
                          0080  Error during reading from instrument.
                          0100  Error using ADC of C-DPU.
                          0200  Error during DAC table generation.
                          0400  Calculated number of samples > N_SAMP_MAX.
                          8800  C-DPU memory exhausted.
                          9000  Measurement time out.
                          2000  Invalid command parameter.
                          8000  Flag indicates fatal error. "
END_OBJECT             = COLUMN