OBJECT                = COLUMN
    NAME              = "SESAME_SEQ_ID"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 1
    BYTES             = 6
    FORMAT            = "I6"
    UNIT              = "N/A"
    DESCRIPTION       = "Sequence ID in the current data file"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME              = "MEAS_ID"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 8
    BYTES             = 6
    FORMAT            = "I6"
    UNIT              = "N/A"
    DESCRIPTION       = "Measurement index, i.e. the number
                         of the measurement in the file.
                         Starts from 1."
END_OBJECT           = COLUMN

OBJECT                = COLUMN
 NAME                 = "UTC"
 DATA_TYPE            = TIME
 START_BYTE           = 15
 BYTES                = 23
    DESCRIPTION       = "Measurement start time (UTC in PDS standard
                         format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT             = COLUMN

OBJECT                = COLUMN
    NAME              = "SESAME_LOCAL_TIME"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 39
    BYTES             = 15
    FORMAT            = "I15"
    DESCRIPTION       = "Start time of measurement. SESAME local time
                         (SLT) runs with a resolution of 1/32 seconds.
                         SLT represents the least significant 32 bits of
                         LOBT. The most significant 5 bits are in
                         CDMS RSST (see SESAME Ready Message)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FREQUENCY_DIVIDER"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 55
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION        = "Value of transmitter frequency control register"
 END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FREQUENCY_INCREMENT"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 59
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "N/A"
    DESCRIPTION        = "Value of sampling rate control registers"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "CHANNELS"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 65
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION       = "Number of sensor channels, derived from SLTLA
                         word (sensor lookup table length and address
                         register)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "AGC"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 69
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "N/A"
    DESCRIPTION       = "Value of amplifier gain control register"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "POWER_SETTING"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 76
    BYTES              = 8
    FORMAT             = "A8"
    UNIT               = "N/A"
    DESCRIPTION        = "Power register setting /mode
                         (hex value):
                         Bits 0 to 3: value of power control register
                         Bits 4 to 7 = 0: power set during measurement
                         initialization
                         Bits 4 to 7 = 1: power set by previous
                         CAS_PWRSW command"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TIME_BURST_ON"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 86
    BYTES              = 10
    FORMAT             = "I10"
    UNIT               = "N/A"
    DESCRIPTION        = "SESAME High Resolution Time at start of recording
                       with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT               = COLUMN
    NAME               = "TIME_BURST_OFF"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 97
    BYTES              = 10
    UNIT               = "N/A"
    FORMAT             = "I10"
    DESCRIPTION        = "SESAME High Resolution Time when recording 
                         with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT               = COLUMN
    NAME               = "FIFO_BURST_OFF"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 109
    BYTES              = 8
    UNIT               = "N/A"
    FORMAT             = "A8"
    DESCRIPTION        = "FIFO address of the final sample after 
                         recording stopped (hex value)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FIFO_FIRST_DAT"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 120
    BYTES              = 8
    UNIT               = "N/A"
    FORMAT             = "A8"
    DESCRIPTION        = "FIFO address of the first sample included
                        in telemetry (hex value)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "NSAMP"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 130
    BYTES              = 10
    FORMAT             = "I10"
    UNIT               = "N/A"
    DESCRIPTION        = "Number of samples per channel in telemetry"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_TRM"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 141
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION        = "-Y_Foot TRM temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_ACC"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 147
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION        = "-Y_Foot ACC temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+X_TRM"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 153
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION        = "+X_Foot TRM temperature before measurement"
END_OBJECT           = COLUMN

OBJECT               = COLUMN
    NAME              = "TEMP_FOOT+X_ACC"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 159
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+X_Foot ACC temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_TRM"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 165
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+Y_Foot TRM temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_ACC"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 171
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION        = "+Y_Foot ACC temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "CASSE_PCB_TEMP"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 177
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION      = "CASSE PCB temperature"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "RADFET_VOLTAGE"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 183
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "MILLIVOLT"
    MISSING_CONSTANT   = 99999
    DESCRIPTION      = "RadFET voltage (0.002 V/mV)"
END_OBJECT           = COLUMN