/* FILE_CONTENTS           = SESAME Health Check */
/*                           Flight software FM3, CODMAC level 3 */
/* FILE_NAME               = SESAME_HC_FM3.FMT */
/* REVISION_NOTE           = SESAME/DIM team, version 1, 2015-11-04 */
/*                           K. Seidensticker, version 2, 2015-11-04 */
/*                           W. Schmidt, version 4, 2015-11-11 */

OBJECT                     = COLUMN
    NAME                   = "UTC"
    DATA_TYPE              = TIME
    START_BYTE             = 1
    BYTES                  = 23
    DESCRIPTION            = "Measurement start time (UTC in PDS standard
                              format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SESAME_LOCAL_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 25
    BYTES                  = 15
    FORMAT                 = "I15"
    DESCRIPTION            = "Measurement start time. SESAME local time
                              (SLT) runs with a resolution of 1/32 seconds.
                              SLT represents the least significant 32 bits
                              of LOBT. The most significant 5 bits are in
                              CDMS RSST (see SESAME Ready Message)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 41
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U-05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 50
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 59
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +12V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U-12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 68
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -12V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+28"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 77
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +28V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UCDP"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 86
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics 
                              Common DPU +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 95
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "MILLIAMPERE"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +5V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I-05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 104
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "MILLIAMPERE"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -5V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 113
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "MILLIAMPERE"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +12V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I-12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 122
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "MILLIAMPERE"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -12V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+28"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 131
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "MILLIAMPERE"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +28V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SUPS"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 140
    BYTES                  = 8
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 16#FFFF#
    DESCRIPTION            = "Common electronics; SRAM usage/  
                              power status (hex value as 16#xxxx#)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TIBO"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 149
    BYTES                  = 6
    FORMAT                 = "I6"
    UNIT                   = "SECOND"
    MISSING_CONSTANT       = 999999
    DESCRIPTION            = "Common electronics 
                              Time since boot"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "ERRF"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 156
    BYTES                  = 8
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 16#FFFF#
    DESCRIPTION            = "Common electronics 
                              Error flags (hex value as 16#xxxx#)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CEID"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 165
    BYTES                  = 8
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 16#FFFF#
    DESCRIPTION            = "Common electronics; SESAME flight 
                              software ID (hex value, FM3: 16#C5E5#)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CLTC"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 174
    BYTES                  = 8
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 16#FFFF#
    DESCRIPTION            = "Common electronics; Last received TC
                              (hex value as 16#xxxx#)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CBTC"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 183
    BYTES                  = 8
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 16#FFFF#
    DESCRIPTION            = "Common electronics; Last but one TC 
                              (hex value as 16#xxxx#)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT-Y"      
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 192
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot -Y/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA-Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 201
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot -Y/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT+X"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 210
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +X/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA+X"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 219
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +X/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT+Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 228
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +Y/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA+Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 237
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +Y/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TPCB"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 246
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE board temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UFPG"          
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 255
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE FPGA 3.3V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "URAD"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 264
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE total dose (RadFET)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UD+5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 273
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "DIM +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UD-5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 282
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "DIM -5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UP+5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 291
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "PP +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "PPD"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 300
    BYTES                  = 5
    FORMAT                 = "I5"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "PP electron density"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "LMID"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 306
    BYTES                  = 5
    FORMAT                 = "I5"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Common electronics 
                              SLT mid word"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "LLOW"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 312
    BYTES                  = 5
    FORMAT                 = "I5"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Common electronics 
                              SLT low word"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL1"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 318
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of temperature channel using 
                              regular HK measurement, for Foot -Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL1"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 327
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"       
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for Foot -Y/TRM" 
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL1"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 336
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for Foot -Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL1"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 345
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot -Y/TRM" 
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL1"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 354
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot -Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 363
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"     
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for Foot -Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 372
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"      
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for Foot -Y/ACC" 
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 381
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.99 
    DESCRIPTION            = "voltage of reference channel 1 = UCDP,
                              for Foot -Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 390
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot -Y/ACC" 
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 399
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"     
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot -Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL3"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 408
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"     
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for Foot +X/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL3"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 417
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              from temperature channel to reference 
                              channel 1, for Foot +X/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL3"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 426
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"  
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for Foot +X/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL3"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 435
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot +X/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL3"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 444
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot +X/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL4"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 453
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for Foot +X/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL4"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 462
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"  
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for Foot +X/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL4"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 471
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"     
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for Foot +X/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL4"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 480
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot +X/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL4"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 489
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"  
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot +X/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 498
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for Foot +Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 507
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for Foot +Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 516
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for Foot +Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 525
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot +Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 534
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT" 
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot +Y/TRM"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL6"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 543
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for Foot +Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL6"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 552
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for Foot +Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL6"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 561
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT" 
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for Foot +Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL6"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 570
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"     
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for Foot +Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL6"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 579
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for Foot +Y/ACC"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-HK_CHANNEL7"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 588
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"                 
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Voltage of temperature channel using
                              regular HK measurement, for CASSE PCB
                              temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I1_CHANNEL7"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 597
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"   
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 1, for CASSE PCB temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R1_CHANNEL7"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 606
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"      
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 1 = UCDP,
                              for CASSE PCB temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-I2_CHANNEL7"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 615
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"    
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Intermediate voltage measured shortly after
                              switching from temperature channel to reference
                              channel 2, for CASSE PCB temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "T-R2_CHANNEL7"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 624
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"  
    MISSING_CONSTANT       = 9999.999 
    DESCRIPTION            = "Voltage of reference channel 2 = U + 28,
                              for CASSE PCB temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "URAD-2"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 633
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE total dose (RadFET),
                              second measurement"
END_OBJECT                 = COLUMN