/* FILE_CONTENTS           = SESAME Housekeeping data */
/*                           Flight software FM3, CODMAC level 3 */
/* FILE_NAME               = SESAME_HK_FM3.FMT */
/* REVISION_NOTE           = SESAME/DIM team, version 1, 2015-10-22 */
/*                           K. Seidensticker, version 2, 2015-10-23 */
/*                           W. Schmidt, version 3, 2015-11-05 */

OBJECT                     = COLUMN
    NAME                   = "UTC"
    DATA_TYPE              = TIME
    START_BYTE             = 1
    BYTES                  = 23
    DESCRIPTION            = "Measurement start time (UTC in PDS standard
                              format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SESAME_LOCAL_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 25
    BYTES                  = 15
    FORMAT                 = "I15"
    DESCRIPTION            = "Measurement start time. SESAME local time
                              (SLT) runs with a resolution of 1/32 seconds.
                              SLT represents the least significant 32 bits
                              of LOBT. The most significant 5 bits are in
                              CDMS RSST (see SESAME Ready Message)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UFPG"          
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 41
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE FPGA 3.3V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UD+5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 50
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "DIM +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UD-5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 59
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "DIM -5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UP+5"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 68
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "PP +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 77
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U-05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 86
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 95
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +12V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U-12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 104
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -12V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "U+28"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 113
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +28V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "UCDP"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 122
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics 
                              Common DPU +5V voltage"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "URAD"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 131
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "VOLT"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE total dose (RadFET)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 140
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "mA"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +5V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I-05"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 149
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "mA"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -5V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 158
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "mA"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +12V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I-12"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 167
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "mA"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics -12V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "I+28"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 176
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "mA"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "Common electronics +28V current"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CEID"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 186
    BYTES                  = 4
    FORMAT                 = "A4"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9999"
    DESCRIPTION            = "Common electronics; SESAME flight
                              software ID (hex value, FM3: C5E5)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TPCB"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 192
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE board temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CLTC"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 202
    BYTES                  = 4
    FORMAT                 = "A4"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9999"
    DESCRIPTION            = "Common electronics 
                              Last received TC (hex value)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "CBTC"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 209
    BYTES                  = 4
    FORMAT                 = "A4"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9999"
    DESCRIPTION            = "Common electronics 
                              Last but one TC (hex value)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT-Y"      
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 215
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot -Y/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA-Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 224
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot -Y/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT+X"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 233
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +X/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA+X"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 242
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +X/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TT+Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 251
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +Y/TRM temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TA+Y"
    DATA_TYPE              = ASCII_REAL
    START_BYTE             = 260
    BYTES                  = 8
    FORMAT                 = "F8.3"
    UNIT                   = "KELVIN"
    MISSING_CONSTANT       = 9999.999
    DESCRIPTION            = "CASSE
                              Foot +Y/ACC temperature"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "PPD"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 269
    BYTES                  = 5
    FORMAT                 = "I5"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "PP electron density"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SUPS"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 276
    BYTES                  = 4
    FORMAT                 = "A4"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9999"
    DESCRIPTION            = "Common electronics 
                              SRAM usage/power status (hex value)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "TIBO"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 282
    BYTES                  = 6
    FORMAT                 = "I6"
    UNIT                   = "SECOND"
    MISSING_CONSTANT       = 999999
    DESCRIPTION            = "Common electronics 
                              Time since boot"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "ERRF"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 290
    BYTES                  = 4
    FORMAT                 = "A4"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9999"
    DESCRIPTION            = "Common electronics 
                              Error flags (hex value)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "LMID"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 296
    BYTES                  = 5
    FORMAT                 = "I5"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Common electronics 
                              SLT mid word"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "LLOW"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 302
    BYTES                  = 5
    FORMAT                 = "I5"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Common electronics 
                              SLT low word"
END_OBJECT                 = COLUMN