/* FILE_CONTENTS      = CASSE temperatures after measurement */
/*                      Level 2, Flight Software FM3
/* FILE_NAME          = CASSE_TAFT_L2_FM3.FMT */
/* REVISION_NOTE      = K. Seidensticker, version 2, 2015-12-04 */

OBJECT                = COLUMN
    NAME              = "SESAME_SEQ_ID"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 1
    BYTES             = 6
    FORMAT            = "I6"
    UNIT              = "N/A"
    DESCRIPTION       = "Sequence ID in the current data file"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "MEAS_ID"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 8
    BYTES             = 6
    FORMAT            = "I6"
    UNIT              = "N/A"
    DESCRIPTION       = "Measurement ID in the current sequence"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT-Y_TRM"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 15
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "-Y-Foot TRM temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT-Y_ACC"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 21
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "-Y Foot ACC temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT+X_TRM"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 27
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+X Foot TRM temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT+X_ACC"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 33
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+X Foot ACC temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT+Y_TRM"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 39
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+Y Foot TRM temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "TEMP_FOOT+Y_ACC"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 45
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "+Y ACC Foot temperature after measurement"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "CASSE_PCB_TEMP"       
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 51
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "CASSE PCB temperature"
END_OBJECT            = COLUMN

OBJECT                = COLUMN
    NAME              = "RADFET_VOLTAGE"       
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 57
    BYTES             = 5
    FORMAT            = "I5"
    UNIT              = "MILLIVOLT"
    MISSING_CONSTANT  = 99999
    DESCRIPTION       = "RadFET voltage"
END_OBJECT            = COLUMN