OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MEAS_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 8 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Measurement ID in the current sequence" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_1" DATA_TYPE = ASCII_REAL START_BYTE = 15 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 1 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_1" DATA_TYPE = ASCII_INTEGER START_BYTE = 26 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_2" DATA_TYPE = ASCII_REAL START_BYTE = 33 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 2 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_2" DATA_TYPE = ASCII_INTEGER START_BYTE = 44 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_3" DATA_TYPE = ASCII_REAL START_BYTE = 51 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 3 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_3" DATA_TYPE = ASCII_INTEGER START_BYTE = 62 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_4" DATA_TYPE = ASCII_REAL START_BYTE = 69 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 4 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_4" DATA_TYPE = ASCII_INTEGER START_BYTE = 80 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_5" DATA_TYPE = ASCII_REAL START_BYTE = 87 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 5 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_5" DATA_TYPE = ASCII_INTEGER START_BYTE = 98 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_6" DATA_TYPE = ASCII_REAL START_BYTE = 105 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 6 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_6" DATA_TYPE = ASCII_INTEGER START_BYTE = 116 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_7" DATA_TYPE = ASCII_REAL START_BYTE = 123 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 7 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_7" DATA_TYPE = ASCII_INTEGER START_BYTE = 134 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_8" DATA_TYPE = ASCII_REAL START_BYTE = 141 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 8 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_8" DATA_TYPE = ASCII_INTEGER START_BYTE = 152 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_9" DATA_TYPE = ASCII_REAL START_BYTE = 159 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 9 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_9" DATA_TYPE = ASCII_INTEGER START_BYTE = 170 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_10" DATA_TYPE = ASCII_REAL START_BYTE = 177 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 10 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_10" DATA_TYPE = ASCII_INTEGER START_BYTE = 188 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_11" DATA_TYPE = ASCII_REAL START_BYTE = 195 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 11 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_11" DATA_TYPE = ASCII_INTEGER START_BYTE = 206 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELATIVE_TIME_12" DATA_TYPE = ASCII_REAL START_BYTE = 213 BYTES = 10 UNIT = "MILLISECOND" FORMAT = "F10.3" MISSING_CONSTANT = 99999.999 DESCRIPTION = "Channel 12 time relative to start time of the measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNEL_12" DATA_TYPE = ASCII_INTEGER START_BYTE = 224 BYTES = 6 FORMAT = "I6" UNIT = "N/A" MISSING_CONSTANT = 999999 DESCRIPTION = "Channel data : - non-linear ADC units for regular (non-stacked) channel data block - linearized stacked ADC units for stacked channel data block The mode (stacked or regular) is given in the job card file (JOBC)" END_OBJECT = COLUMN