/* FILE_CONTENTS           = DIM Burst Continuous PAR data */
/*                           Flight software FM1, FM2, FM3, CODMAC level 2 */
/* FILE_NAME               = DIM_BC_PAR.FMT */
/* REVISION_NOTE           = H. Krueger, version 1, 2015-08-18 */
/*                           A. Hirn, version 2, 2015-11-20 */

OBJECT                     = COLUMN
    NAME                   = "SESAME_SEQ_ID"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 1
    BYTES                  = 6
    FORMAT                 = "I6"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 999999
    DESCRIPTION            = "Sequence ID in the current data file"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SESAME_LOCAL_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 8
    BYTES                  = 15
    FORMAT                 = "I15"
    DESCRIPTION            = "Time at end of measuring period.
                              SESAME local time
                              (SLT) runs with a resolution of 1/32 seconds.
                              SLT represents the least significant 32 bits
                              of LOBT. The most significant 5 bits are in
                              CDMS RSST (see SESAME Ready Message)"
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "DIRECTION"
    DATA_TYPE              = CHARACTER
    START_BYTE             = 25
    BYTES                  = 1
    FORMAT                 = "A1"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = "9"
    DESCRIPTION            = "Direction in DIM coordinate system, X, Y or Z.
                              Echoed command parameter."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "MARGIN"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 28
    BYTES                  = 2
    FORMAT                 = "I2"
    UNIT                   = "DECIBEL"
    MISSING_CONSTANT       = 99
    DESCRIPTION            = "The margin determines the detection
                              threshold of the measuring amplifier.
                              Echoed command parameter. "
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "DECAY_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 31
    BYTES                  = 3
    FORMAT                 = "I3"
    UNIT                   = "MILLISECOND"
    MISSING_CONSTANT       = 999
    DESCRIPTION            = "Signal decay time.
                              Range from 0 to 255.
                              Echoed command parameter."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "SAMPLING_INTERVAL"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 35
    BYTES                  = 5
    FORMAT                 = "I5"
    UNIT                   = "SECOND"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Sampling time interval.
                              Echoed command parameter."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "MEAS_TIME"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 41
    BYTES                  = 5
    FORMAT                 = "I5"    
    UNIT                   = "SECOND"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Measuring time.
                              Echoed command parameter."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "NEVENT"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 47
    BYTES                  = 5
    FORMAT                 = "I5"    
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Number of events detected."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "N_FALSE_EVENTS"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 53
    BYTES                  = 5
    FORMAT                 = "I5"
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Number of false events."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "N_LONG_EVENTS"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 59
    BYTES                  = 5
    FORMAT                 = "I5" 
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Number of long events."
END_OBJECT                 = COLUMN

OBJECT                     = COLUMN
    NAME                   = "N_AV_SAMPLES"
    DATA_TYPE              = ASCII_INTEGER
    START_BYTE             = 65
    BYTES                  = 5
    FORMAT                 = "I5"    
    UNIT                   = "N/A"
    MISSING_CONSTANT       = 99999
    DESCRIPTION            = "Number of average samples."
END_OBJECT                 = COLUMN