OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MEAS_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 8 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Measurement index, i.e. the number of the measurement in the file. Starts from 1." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 15 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 39 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Start time of measurement. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_DIVIDER" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Value of transmitter frequency control register" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_INCREMENT" DATA_TYPE = ASCII_INTEGER START_BYTE = 59 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Value of sampling rate control registers" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNELS" DATA_TYPE = ASCII_INTEGER START_BYTE = 65 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Number of sensor channels, derived from SLTLA word (sensor lookup table length and address register)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AGC" DATA_TYPE = ASCII_INTEGER START_BYTE = 69 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Value of amplifier gain control register" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POWER_SETTING" DATA_TYPE = CHARACTER START_BYTE = 76 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Power register setting /mode (hex value): Bits 0 to 3: value of power control register Bits 4 to 7 = 0: power set during measurement initialization Bits 4 to 7 = 1: power set by previous CAS_PWRSW command" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_ON" DATA_TYPE = ASCII_INTEGER START_BYTE = 86 BYTES = 10 FORMAT = "I10" UNIT = "N/A" DESCRIPTION = "SESAME High Resolution Time at start of recording with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 97 BYTES = 10 UNIT = "N/A" FORMAT = "I10" DESCRIPTION = "SESAME High Resolution Time when recording with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_BURST_OFF" DATA_TYPE = CHARACTER START_BYTE = 109 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO address of the final sample after recording stopped (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_FIRST_DAT" DATA_TYPE = CHARACTER START_BYTE = 120 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO address of the first sample included in telemetry (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NSAMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 130 BYTES = 10 FORMAT = "I10" UNIT = "N/A" DESCRIPTION = "Number of samples per channel in telemetry" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_TRM" DATA_TYPE = ASCII_INTEGER START_BYTE = 141 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "-Y_Foot TRM temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_ACC" DATA_TYPE = ASCII_INTEGER START_BYTE = 147 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "-Y_Foot ACC temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_TRM" DATA_TYPE = ASCII_INTEGER START_BYTE = 153 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "+X_Foot TRM temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_ACC" DATA_TYPE = ASCII_INTEGER START_BYTE = 159 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "+X_Foot ACC temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_TRM" DATA_TYPE = ASCII_INTEGER START_BYTE = 165 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "+Y_Foot TRM temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_ACC" DATA_TYPE = ASCII_INTEGER START_BYTE = 171 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "+Y_Foot ACC temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_PCB_TEMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 177 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RADFET_VOLTAGE" DATA_TYPE = ASCII_INTEGER START_BYTE = 183 BYTES = 5 FORMAT = "I5" UNIT = "MILLIVOLT" MISSING_CONSTANT = 99999 DESCRIPTION = "RadFET voltage (0.002 V/mV)" END_OBJECT = COLUMN