/* PP AM2 data / calibrated, version 2, 2015-11-14 */ /* The measurement time is given in the parameters file */ /* PP_AM2_PAR.FMT */ OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "USED_FREQUENCY" DATA_TYPE = ASCII_REAL START_BYTE = 8 BYTES = 8 UNIT = "HERTZ" FORMAT = "F8.2" DESCRIPTION = "Corrected frequency from lookup-table" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TX_OUT_AMPLITUDE" DATA_TYPE = ASCII_REAL START_BYTE = 17 BYTES = 5 UNIT = "VOLT" FORMAT = "F5.2" DESCRIPTION = "TX Voltage Amplitude generated" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ERROR_CODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 23 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#0000# DESCRIPTION = "Hex value as 16#xxxx#. The possible values are: 8001 Invalid register address. 8002 Error verifying register write. 8004 Error accessing power register. 8008 MUX setting not allowed. 8010 Error accessing PP RAM. 8020 Tried to start measurement but a measurement is already running. 0040 Error during writing to instrument. 0080 Error during reading from instrument. 0100 Error using ADC of C-DPU. 0200 Error during DAC table generation. 0400 Calculated number of samples > N_SAMP_MAX. 8800 C-DPU memory exhausted. 9000 Measurement time out. 2000 Invalid command parameter. 8000 Flag indicates fatal error. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "QUAL_FLAG_CH" DATA_TYPE = ASCII_INTEGER START_BYTE = 32 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "PP quality flags. The possible values are: 0 OK 1 at least one sample equals 255 in current (transmitter) time series" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "QUAL_FLAG_CL" DATA_TYPE = ASCII_INTEGER START_BYTE = 34 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "PP quality flags. The possible values are: 0 OK 1 at least one sample equals 0 in current (transmitter) time series" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "QUAL_FLAG_VH" DATA_TYPE = ASCII_INTEGER START_BYTE = 36 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "PP quality flags. The possible values are: 0 OK 1 at least one sample equals 255 in voltage (receiver) time series" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "QUAL_FLAG_VL" DATA_TYPE = ASCII_INTEGER START_BYTE = 38 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "PP quality flags. The possible values are: 0 OK 1 at least one sample equals 0 in voltage (receiver) time series" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POINTS_PER_WAVE" DATA_TYPE = ASCII_INTEGER START_BYTE = 40 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "Number of points per wave used by receiver" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PHASE" DATA_TYPE = ASCII_REAL START_BYTE = 44 BYTES = 8 UNIT = "DEGREE" FORMAT = "F8.4" DESCRIPTION = "Phase difference potential-current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_AMPLITUDE" DATA_TYPE = ASCII_REAL START_BYTE = 53 BYTES = 8 UNIT = "MILLIAMPERE" FORMAT = "F8.6" DESCRIPTION = "Averaged current amplitude at electronics board" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VOLTAGE_AMPLITUDE" DATA_TYPE = ASCII_REAL START_BYTE = 62 BYTES = 7 UNIT = "MILLIVOLT" FORMAT = "F7.3" DESCRIPTION = "Averaged amplitude of Rx voltage diff." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MATH_ERR_CODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 70 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#0000# DESCRIPTION = "Indicates errors, which can only occur during on-board data reduction (hex value as 16#xxxx#). 0001 Reduce: number of vector elements odd or less than 2; fatal. 0002 Expand: less than four elements in input vector; fatal. 0004 Too much data for analysis; truncating. 0008 Too few data for analysis; padding with '128' 0010 Used number of waves is not a power of 2; truncated. 0020 Not the expected number of elements in filtered arrays; fatal. 0040 Argument for sine_table() not in valid range 0<= deg2 <=720. 0080 Overflow in divsin() or result inexact. 0100 Too few data for trimmed mean calculation; regular mean used. 0200 No data for warr.mean; particular: analysis yields no data. 0400 Passive mode: not enough data in bin. 0800 Not enough memory for data reduction." END_OBJECT = COLUMN