/* PP AMTEST2 parameter settings / calibrated, version 3, 2015-12-16 */ OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 8 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 32 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Measurement start time. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SENSOR_SETTINGS_USED" DATA_TYPE = ASCII_INTEGER START_BYTE = 48 BYTES = 7 UNIT = "N/A" DESCRIPTION = "Used electrode combination as 3-digit hexadecimal code 16#abi# with the following meaning: a: electrode connected to the TX A output. Possible values: 0 [none], 1 [+X leg], 2 [MUPUS PEN] b: electrode connected to the TX B output. Possible values: 0 [none], 2 [MUPUS PEN], 3 [APX] i: input channel Possible values: 0 [potential difference] 1 [current at +X leg] 2 [current at MUPUS PEN] 3 [current at APX] 4 [direct measurement at +Y foot] 5 [direct measurement at - foot] 6 [reference voltage -2.5 V] 7 [reference voltage +2.5 V] " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NOMINAL_FREQUENCY" DATA_TYPE = ASCII_INTEGER START_BYTE = 56 BYTES = 5 UNIT = "HZ" FORMAT = "I5" DESCRIPTION = "Nominal transmitter frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CORRECTED_FREQUENCY" DATA_TYPE = ASCII_REAL START_BYTE = 62 BYTES = 8 UNIT = "HZ" FORMAT = "F8.2" DESCRIPTION = "Corrected transmitter frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUMBER_OF_WAVES" DATA_TYPE = ASCII_INTEGER START_BYTE = 71 BYTES = 2 UNIT = "N/A" FORMAT = "I2" DESCRIPTION = "Number of generated transmitter sine waves" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RX_SAMPLING_FREQUENCY" DATA_TYPE = ASCII_REAL START_BYTE = 74 BYTES = 8 UNIT = "HZ" FORMAT = "F8.1" DESCRIPTION = "Receiver sampling frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RX_SAMPLING_FREQUENCY" DATA_TYPE = ASCII_REAL START_BYTE = 83 BYTES = 8 UNIT = "HZ" FORMAT = "F8.1" DESCRIPTION = "Transmitter DAC sampling frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NO_OF_DAC_VALUES" DATA_TYPE = ASCII_INTEGER START_BYTE = 92 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "DAC vector length" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TX_OUT_DAMPING" DATA_TYPE = ASCII_INTEGER START_BYTE = 96 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "TX Voltage Amplitude Reduction. The possible values are: 0 maximum amplitude. 1 half amplitude. 2 quarter amplitude. 3 1/8 amplitude. 4 1/16 amplitude." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POINTS_PER_WAVE" DATA_TYPE = ASCII_INTEGER START_BYTE = 98 BYTES = 3 UNIT = "N/A" FORMAT = "I3" MISSING_CONSTANT = 999 DESCRIPTION = "Number of points per wave used by receiver " END_OBJECT = COLUMN