/* PP Healtch Check / calibrated, version 2, 2015-11-14 */ OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 8 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 32 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Measurement start time. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LP_VALUE" DATA_TYPE = ASCII_INTEGER START_BYTE = 48 BYTES = 5 UNIT = "N/A" FORMAT = "I5" DESCRIPTION = "Result count of Langmuir probe measurement/not calibrated " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ADC_OFFSET" DATA_TYPE = ASCII_REAL START_BYTE = 54 BYTES = 7 UNIT = "VOLT" FORMAT = "F7.4" DESCRIPTION = "Should be close to 0 V" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "-2.5V REF" DATA_TYPE = ASCII_REAL START_BYTE = 62 BYTES = 7 UNIT = "VOLT" FORMAT = "F7.4" DESCRIPTION = "-2.5V REF and +2.5V REF should be nearly symmetrical to ADC offset" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "+2.5V_REF" DATA_TYPE = ASCII_REAL START_BYTE = 70 BYTES = 7 UNIT = "VOLT" FORMAT = "F7.4" DESCRIPTION = "-2.5V REF and +2.5V REF should be nearly symmetrical to ADC offset" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA" DATA_TYPE = ASCII_REAL START_BYTE = 78 BYTES = 7 UNIT = "VOLT" FORMAT = "F7.4" DESCRIPTION = "Differential value -Y foot - +Y foot" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LEG+Y_RX1" DATA_TYPE = ASCII_REAL START_BYTE = 86 BYTES = 8 UNIT = "MILLIVOLT" FORMAT = "F8.3" DESCRIPTION = "Direct voltage from receiver 1 at +Y leg (at 20C)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LEG-Y_RX2" DATA_TYPE = ASCII_REAL START_BYTE = 95 BYTES = 8 UNIT = "MILLIVOLT" FORMAT = "F8.3" DESCRIPTION = "Direct voltage from receiver 2 at -Y leg (at 20C)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LEG+X_TX1" DATA_TYPE = ASCII_REAL START_BYTE = 104 BYTES = 9 UNIT = "MILLIAMPERE" FORMAT = "F9.6" DESCRIPTION = "Transmitter current at electrode 1. No voltage applied. Should be close to 0 mA" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MUPUS_PEN_TX2" DATA_TYPE = ASCII_REAL START_BYTE = 114 BYTES = 9 UNIT = "MILLIAMPERE" FORMAT = "F9.6" DESCRIPTION = "Transmitter current at electrode 2. No voltage applied. Should be close to 0 mA" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APXS_TX3" DATA_TYPE = ASCII_REAL START_BYTE = 124 BYTES = 9 UNIT = "MILLIAMPERE" FORMAT = "F9.6" DESCRIPTION = "Transmitter current at electrode 3. No voltage applied. Should be close to 0 mA" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ERROR_CODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 134 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#0000# DESCRIPTION = "Hex value as 16#xxxx#. The possible values are: 8001 Invalid register address. 8002 Error verifying register write. 8004 Error accessing power register. 8008 MUX setting not allowed. 8010 Error accessing PP RAM. 8020 Tried to start measurement but a measurement is already running. 0040 Error during writing to instrument. 0080 Error during reading from instrument. 0100 Error using ADC of C-DPU. 0200 Error during DAC table generation. 0400 Calculated number of samples > N_SAMP_MAX. 8800 C-DPU memory exhausted. 9000 Measurement time out. 2000 Invalid command parameter. 8000 Flag indicates fatal error. " END_OBJECT = COLUMN