OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MEAS_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 8 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Measurement index, i.e. the number of the measurement in the file. Starts from 1." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 15 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 39 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Start time of measurement. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_DIVIDER" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Value of transmitter frequency control register" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_INCREMENT" DATA_TYPE = ASCII_INTEGER START_BYTE = 59 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Value of sampling rate control registers" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNELS" DATA_TYPE = ASCII_INTEGER START_BYTE = 65 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Number of sensor channels, derived from SLTLA word (sensor lookup table length and address register)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AGC" DATA_TYPE = ASCII_REAL START_BYTE = 69 BYTES = 6 FORMAT = "F6.2" UNIT = "N/A" DESCRIPTION = "Nominal amplifier gain; calculated by multiplying the gains of the active amplification stages indicated by the control register settings. An active amplifier stage is signified by the corresponding bit set to 0. Bits are counted from right to left Bit 1 nominal gain factor: 3.13 Bit 2 nominal gain factor: 2.13 Bit 3 nominal gain factor: 4.55 Bit 4 nominal gain factor: 5.55 Bit pattern 1010 represents a nominal gain of 5.55 * 2.13 = 11.82" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POWER_SETTING" DATA_TYPE = CHARACTER START_BYTE = 77 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Power register setting /mode This is a character string where each character represents one bit. Bits 0 to 3: value of power control register Bits 4 to 7 = 0: power set during measurement initialization Bits 4 to 7 = 1: power set by previous CAS_PWRSW command " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_ON" DATA_TYPE = ASCII_INTEGER START_BYTE = 87 BYTES = 10 UNIT = "N/A" FORMAT = "I10" DESCRIPTION = "SESAME High Resolution Time at start of recording with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 98 BYTES = 10 UNIT = "N/A" FORMAT = "I10" DESCRIPTION = "SESAME High Resolution Time when recording was stopped with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_BURST_OFF" DATA_TYPE = CHARACTER START_BYTE = 110 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO address of the final sample after recording stopped (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_FIRST_DAT" DATA_TYPE = CHARACTER START_BYTE = 121 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO address of the first sample included in telemetry (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NSAMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 131 BYTES = 10 FORMAT = "I10" UNIT = "N/A" DESCRIPTION = "Number of samples per channel in telemetry" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 142 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 149 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 156 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 163 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 170 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 177 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_PCB_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 184 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RADFET_VOLTAGE" DATA_TYPE = ASCII_REAL START_BYTE = 191 BYTES = 6 FORMAT = "F6.3" UNIT = "MILLIVOLT" DESCRIPTION = "RadFET voltage (0.002 V/mV)" END_OBJECT = COLUMN