OBJECT                = COLUMN
    NAME               = "SESAME_SEQ_ID"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 1
    BYTES              = 6
    FORMAT             = "I6"
    UNIT               = "N/A"
    DESCRIPTION  = "Sequence ID in the current data file"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME              = "MEAS_ID"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 8
    BYTES             = 6
    FORMAT            = "I6"
    UNIT              = "N/A"
    DESCRIPTION       = "Measurement index, i.e. the number
                         of the measurement in the file.
                         Starts from 1."
END_OBJECT   = COLUMN

OBJECT                  = COLUMN
  NAME                  = "UTC"
  DATA_TYPE             = TIME
  START_BYTE            = 15
  BYTES                 = 23
    DESCRIPTION       = "Measurement start time (UTC in PDS standard
                         format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "SESAME_LOCAL_TIME"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 39
    BYTES              = 15
    FORMAT             = "I15"
 DESCRIPTION  = "Start time of measurement. SESAME local time
                         (SLT) runs with a resolution of 1/32 seconds.
                         SLT represents the least significant 32 bits of
                         LOBT. The most significant 5 bits are in
                         CDMS RSST (see SESAME Ready Message)"
END_OBJECT           = COLUMN

OBJECT                 = COLUMN
    NAME               = "FREQUENCY_DIVIDER"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 55
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION  = "Value of transmitter frequency control register"
 END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "FREQUENCY_INCREMENT"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 59
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "N/A"
    DESCRIPTION  = "Value of sampling rate control registers"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "CHANNELS"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 65
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION  = "Number of sensor channels, derived from SLTLA word
                        (sensor lookup table length and address register)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "AGC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 69
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "N/A"
    DESCRIPTION       = "Nominal amplifier gain; calculated by
                         multiplying the gains of the active
                         amplification stages indicated by the
                         control register settings. An active
                         amplifier stage is signified by the
                         corresponding bit set to 0.
                         Bits are counted from right to left
                         Bit 1 nominal gain factor: 3.13
                         Bit 2 nominal gain factor: 2.13
                         Bit 3 nominal gain factor: 4.55
                         Bit 4 nominal gain factor: 5.55
                         Bit pattern 1010 represents a nominal
                         gain of 5.55 * 2.13 = 11.82"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "POWER_SETTING"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 77
    BYTES              = 8
    FORMAT             = "A8"
    UNIT               = "N/A"
    DESCRIPTION      = "Power register setting /mode
                         This is a character string where each
                         character represents one bit.
                Bits 0 to 3: value of power control register
                Bits 4 to 7 = 0: power set during measurement initialization
                Bits 4 to 7 = 1: power set by previous CAS_PWRSW command
                        "
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TIME_BURST_ON"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 87
    BYTES              = 10
    UNIT               = "N/A"
    FORMAT             = "I10"
    DESCRIPTION  = "SESAME High Resolution Time at start of recording
                       with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TIME_BURST_OFF"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 98
    BYTES              = 10
    UNIT               = "N/A"
    FORMAT             = "I10"
    DESCRIPTION  = "SESAME High Resolution Time when recording 
                         was stopped with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FIFO_BURST_OFF"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 110
    BYTES              = 8
    UNIT               = "N/A"
    FORMAT             = "A8"
    DESCRIPTION  = "FIFO address of the final sample after 
                         recording stopped (hex value)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FIFO_FIRST_DAT"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 121
    BYTES              = 8
    UNIT               = "N/A"
    FORMAT            = "A8"
    DESCRIPTION      = "FIFO address of the first sample included
                        in telemetry (hex value)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "NSAMP"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 131
    BYTES              = 10
    FORMAT             = "I10"
    UNIT               = "N/A"
    DESCRIPTION  = "Number of samples per channel in telemetry"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 142
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 149
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+X_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 156
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+X_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 163
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 170
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 177
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "CASSE_PCB_TEMP"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 184
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION      = "CASSE PCB temperature"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "RADFET_VOLTAGE"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 191
    BYTES              = 6
    FORMAT             = "F6.3"
    UNIT               = "MILLIVOLT"
    DESCRIPTION      = "RadFET voltage (0.002 V/mV)"
END_OBJECT           = COLUMN