OBJECT                = COLUMN
    NAME               = "SESAME_SEQ_ID"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 1
    BYTES              = 6
    FORMAT             = "I6"
    UNIT               = "N/A"
    DESCRIPTION      = "Sequence ID in the current data file"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "MEAS_ID"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 8
    BYTES              = 6
    FORMAT             = "I6"
    UNIT               = "N/A"
    DESCRIPTION      = "Measurement ID in the current sequence"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
  NAME                 = "UTC"
  DATA_TYPE            = TIME
  START_BYTE           = 15
  BYTES                = 23
    DESCRIPTION       = "Measurement start time (UTC in PDS standard
                         format YYYY-MM-DDThh:mm:ss.sss)"
END_OBJECT             = COLUMN

OBJECT                = COLUMN
    NAME              = "SESAME_LOCAL_TIME"
    DATA_TYPE         = ASCII_INTEGER
    START_BYTE        = 39
    BYTES              = 15
 FORMAT               = "I15"
 DESCRIPTION  = "Start time of measurement. SESAME local time
                         (SLT) runs with a resolution of 1/32 seconds.
                         SLT represents the least significant 32 bits of
                         LOBT. The most significant 5 bits are in
                         CDMS RSST (see SESAME Ready Message)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "FREQUENCY_DIVIDER"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 55
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION  = "Value of transmitter frequency control register"
 END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "FREQUENCY_INCREMENT"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 59
    BYTES              = 5
    FORMAT             = "I5"
    UNIT               = "N/A"
    DESCRIPTION  = "Value of sampling rate control registers"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "CHANNELS"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 65
    BYTES              = 3
    FORMAT             = "I3"
    UNIT               = "N/A"
    DESCRIPTION  = "Number of sensor channels, derived from SLTLA word
                        (sensor lookup table length and address register)"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "AGC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 69
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "N/A"
    DESCRIPTION       = "Nominal amplifier gain; calculated by
                         multiplying the gains of the active
                         amplification stages indicated by the
                         control register settings. An active
                         amplifier stage is signified by the
                         corresponding bit set to 0.
                         Bits are counted from right to left
                         Bit 1 nominal gain factor: 3.13
                         Bit 2 nominal gain factor: 2.13
                         Bit 3 nominal gain factor: 4.55
                         Bit 4 nominal gain factor: 5.55
                         Bit pattern 1010 represents a nominal
                         gain of 5.55 * 2.13 = 11.82"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "POWER_SETTING"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 77
    BYTES              = 8
    FORMAT            = "A8"
    UNIT               = "N/A"
    DESCRIPTION      = "Power register setting /mode            
                         This is a character string where each
                         character represents one bit.
                Bits 0 to 3: value of power control register
                Bits 4 to 7 = 0: power set during measurement initialization
                Bits 4 to 7 = 1: power set by previous CAS_PWRSW command "
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TRIGGER_STATUS"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 88
    BYTES              = 12
    FORMAT             = "A12"
    UNIT               = "N/A"
    DESCRIPTION      = "This is a Bit Pattern indicating which of the
                         selected trigger channels triggered the
                         recording bit field represented as 12 characters, 
                         the rightmost character corresponds to bit #0 
                         and the leftmost to bit #11.  
                         Each character can be 1 (active sensor used as a
                         trigger source) or 0 (sensor not used as a
                         trigger source) and have the following meaning.
                         bit  0: ACC -Y, x-axis
                         bit  1: ACC -Y, y-axis
                         bit  2: ACC -Y, z-axis
                         bit  3: ACC +X, x-axis
                         bit  4: ACC +X, y-axis
                         bit  5: ACC +X, z-axis
                         bit  6: ACC +Y, x-axis
                         bit  7: ACC +Y, y-axis
                         bit  8: ACC +Y, z-axis
                         bit  9: TRM -Y
                         bit 10: TRM +X
                         bit 11: TRM +Y"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TIME_BURST_ON"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 102
    BYTES              = 10
    UNIT               = "N/A"
    FORMAT             = "I10"              
    DESCRIPTION      = "SESAME High Resolution Time at start of recording
                       with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
 NAME                  = "TIME_TRIGGER"
 DATA_TYPE             = ASCII_INTEGER
 START_BYTE            = 113
 BYTES                 = 10
 FORMAT                = "I10"     
 UNIT               = "N/A" 
 DESCRIPTION          = "SESAME High Resolution Time when trigger
                         event occurred with a resolution of 1/1024 s"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "TIME_BURST_OFF"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 124
    BYTES              = 10
    UNIT               = "N/A"
    FORMAT             = "I10"              
    DESCRIPTION      = "SESAME High Resolution Time when recording 
                         was stopped with a resolution of 1/1024 s"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
 NAME                  = "FIFO_TRIGGER"
 DATA_TYPE             = CHARACTER
 START_BYTE            = 136
 BYTES                 = 8
 FORMAT                = "A8"                 
 DESCRIPTION       = "FIFO RAM address when trigger occurred
                         (hex value, 4 bytes)"
END_OBJECT   = COLUMN

OBJECT                   = COLUMN
    NAME                 = "FIFO_BURST_OFF"
    DATA_TYPE            = CHARACTER
    START_BYTE           = 147
    BYTES                = 8
    UNIT                 = "N/A"
    FORMAT              = "A8"
DESCRIPTION   = "FIFO RAM address when recording stopped
                         (hex value, 4 bytes)"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "FIFO_FIRST_DAT"
    DATA_TYPE          = CHARACTER
    START_BYTE         = 158
    BYTES              = 8
    UNIT               = "N/A"
    FORMAT             = "A8"
DESCRIPTION           = "FIFO RAM address of very first channel
                         data (hex value, 4 bytes)"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "NSAMP"
    DATA_TYPE          = ASCII_INTEGER
    START_BYTE         = 168
    BYTES              = 10
    FORMAT             = "I10"
    UNIT               = "N/A"
    DESCRIPTION      = "Number of samples per channel in telemetry"
END_OBJECT   = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 179
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT-Y_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 186
    BYTES              = 6
    FORMAT            = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+X_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 193
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+X_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 200
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_TRM"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 207
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "TEMP_FOOT+Y_ACC"
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 214
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION       = "Sensor temperature before measurement"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "CASSE_PCB_TEMP"       
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 221
    BYTES              = 6
    FORMAT             = "F6.2"
    UNIT               = "KELVIN"
    DESCRIPTION      = "CASSE PCB temperature"
END_OBJECT           = COLUMN

OBJECT                = COLUMN
    NAME               = "RADFET_VOLTAGE"       
    DATA_TYPE          = ASCII_REAL
    START_BYTE         = 228
    BYTES              = 6
    FORMAT             = "F6.3"
    UNIT               = "MILLIVOLT"
    DESCRIPTION      = "RadFET voltage (0.002 V/mV)"
END_OBJECT           = COLUMN