OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MEAS_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 8 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Measurement ID in the current sequence" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 15 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 39 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Start time of measurement. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_DIVIDER" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Value of transmitter frequency control register" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_INCREMENT" DATA_TYPE = ASCII_INTEGER START_BYTE = 59 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Value of sampling rate control registers" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNELS" DATA_TYPE = ASCII_INTEGER START_BYTE = 65 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Number of sensor channels, derived from SLTLA word (sensor lookup table length and address register)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AGC" DATA_TYPE = ASCII_REAL START_BYTE = 69 BYTES = 6 FORMAT = "F6.2" UNIT = "N/A" DESCRIPTION = "Nominal amplifier gain; calculated by multiplying the gains of the active amplification stages indicated by the control register settings. An active amplifier stage is signified by the corresponding bit set to 0. Bits are counted from right to left Bit 1 nominal gain factor: 3.13 Bit 2 nominal gain factor: 2.13 Bit 3 nominal gain factor: 4.55 Bit 4 nominal gain factor: 5.55 Bit pattern 1010 represents a nominal gain of 5.55 * 2.13 = 11.82" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POWER_SETTING" DATA_TYPE = CHARACTER START_BYTE = 77 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Power register setting /mode This is a character string where each character represents one bit. Bits 0 to 3: value of power control register Bits 4 to 7 = 0: power set during measurement initialization Bits 4 to 7 = 1: power set by previous CAS_PWRSW command " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_STATUS" DATA_TYPE = CHARACTER START_BYTE = 88 BYTES = 12 FORMAT = "A12" UNIT = "N/A" DESCRIPTION = "This is a Bit Pattern indicating which of the selected trigger channels triggered the recording bit field represented as 12 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #11. Each character can be 1 (active sensor used as a trigger source) or 0 (sensor not used as a trigger source) and have the following meaning. bit 0: ACC -Y, x-axis bit 1: ACC -Y, y-axis bit 2: ACC -Y, z-axis bit 3: ACC +X, x-axis bit 4: ACC +X, y-axis bit 5: ACC +X, z-axis bit 6: ACC +Y, x-axis bit 7: ACC +Y, y-axis bit 8: ACC +Y, z-axis bit 9: TRM -Y bit 10: TRM +X bit 11: TRM +Y" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_ON" DATA_TYPE = ASCII_INTEGER START_BYTE = 102 BYTES = 10 UNIT = "N/A" FORMAT = "I10" DESCRIPTION = "SESAME High Resolution Time at start of recording with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_TRIGGER" DATA_TYPE = ASCII_INTEGER START_BYTE = 113 BYTES = 10 FORMAT = "I10" UNIT = "N/A" DESCRIPTION = "SESAME High Resolution Time when trigger event occurred with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 124 BYTES = 10 UNIT = "N/A" FORMAT = "I10" DESCRIPTION = "SESAME High Resolution Time when recording was stopped with a resolution of 1/1024 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_TRIGGER" DATA_TYPE = CHARACTER START_BYTE = 136 BYTES = 8 FORMAT = "A8" DESCRIPTION = "FIFO RAM address when trigger occurred (hex value, 4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_BURST_OFF" DATA_TYPE = CHARACTER START_BYTE = 147 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO RAM address when recording stopped (hex value, 4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_FIRST_DAT" DATA_TYPE = CHARACTER START_BYTE = 158 BYTES = 8 UNIT = "N/A" FORMAT = "A8" DESCRIPTION = "FIFO RAM address of very first channel data (hex value, 4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NSAMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 168 BYTES = 10 FORMAT = "I10" UNIT = "N/A" DESCRIPTION = "Number of samples per channel in telemetry" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 179 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 186 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 193 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 200 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 207 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 214 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Sensor temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_PCB_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 221 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RADFET_VOLTAGE" DATA_TYPE = ASCII_REAL START_BYTE = 228 BYTES = 6 FORMAT = "F6.3" UNIT = "MILLIVOLT" DESCRIPTION = "RadFET voltage (0.002 V/mV)" END_OBJECT = COLUMN