/* Contents of format file "ROMAP_SPM_RAW_ION.FMT" */ /* Ion spectrum definition (Level 3) */ /* (I1CRT or I2CRT), raw mode (channels 1 or 2) */ /* ************************************************************ */ /* Include the HEADER at the beginning of each measurment */ /* ************************************************************ */ OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 DESCRIPTION = "This column represents the UTC Of the SPM spectrum in PDS standard format YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OBT" DATA_TYPE = ASCII_REAL START_BYTE = 25 BYTES = 15 UNIT = SECOND FORMAT = "F15.5" DESCRIPTION = "ROMAP 4 bytes counter representing the measurement time synchronized with Lander On Board Time. The time resolution is 0.03125 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MODE" DATA_TYPE = CHARACTER START_BYTE = 42 BYTES = 9 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "SPM mode: raw or parameter" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EXPOSITION_TIME" DATA_TYPE = CHARACTER START_BYTE = 54 BYTES = 5 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "SPM exposition time setting: short or long" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIBRATION" DATA_TYPE = CHARACTER START_BYTE = 62 BYTES = 8 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "SPM calibration status: active or inactive" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CEM_SUPPLY" DATA_TYPE = ASCII_INTEGER START_BYTE = 72 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "SPM CEM supply setting: step number from 1 to 5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RESOLUTION" DATA_TYPE = CHARACTER START_BYTE = 75 BYTES = 4 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "SPM resolution setting: low or high" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ION_CHANNEL" DATA_TYPE = CHARACTER START_BYTE = 82 BYTES = 8 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "Ion channel status: Both_off Ion1 Ion2 Both_on" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EVEN_ODD" DATA_TYPE = CHARACTER START_BYTE = 93 BYTES = 8 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "Indicates whether all energies are transmitted (64 for full resolution and 32 for low resolution) or even/odd energies alternatively. Takes the values: even_odd or full" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I1_X_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 103 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "X component of unit vector aligned with Ion 1 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I1_Y_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 110 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Y component of unit vector aligned with Ion 1 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I1_Z_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 117 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Z component of unit vector aligned with Ion 1 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I2_X_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 124 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "X component of unit vector aligned with Ion 2 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I2_Y_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 131 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Y component of unit vector aligned with Ion 2 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I2_Z_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 138 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Z component of unit vector aligned with Ion 2 detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EL_X_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 145 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "X component of unit vector aligned with electron detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EL_Y_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 152 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Y component of unit vector aligned with electron detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EL_Z_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 159 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Z component of unit vector aligned with electron detector in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FC_X_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 166 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "X component of unit vector aligned with Faraday cup in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FC_Y_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 173 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Y component of unit vector aligned with Faraday cup in ECLIPJ2000 coordinates" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FC_Z_ECLIPJ2000" DATA_TYPE = ASCII_REAL START_BYTE = 180 BYTES = 6 FORMAT = "F6.3" UNIT = "N/A" DESCRIPTION = "Z component of unit vector aligned with Faraday cup in ECLIPJ2000 coordinates" END_OBJECT = COLUMN /* ************************************************************ */ /* Add index and type columns */ /* Index column : measurment number */ /* Type column : measurment type (I1CRT or I2CRT) */ /* ************************************************************ */ OBJECT = COLUMN NAME = "INDEX" DATA_TYPE = ASCII_INTEGER START_BYTE = 187 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Measurment index" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TYPE" DATA_TYPE = CHARACTER START_BYTE = 194 BYTES = 5 FORMAT = "N/A" UNIT = "N/A" DESCRIPTION = "Measurment type (I1CRT or I2CRT)" END_OBJECT = COLUMN /* ********************************************************** */ OBJECT = COLUMN NAME = "ENERGY" DATA_TYPE = ASCII_REAL START_BYTE = 201 BYTES = 7 FORMAT = "F7.2" UNIT = "ELECTRONVOLT" DESCRIPTION = "Energy step" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_1" DATA_TYPE = ASCII_REAL START_BYTE = 209 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 1 (-31 deg)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_2" DATA_TYPE = ASCII_REAL START_BYTE = 218 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_3" DATA_TYPE = ASCII_REAL START_BYTE = 227 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 3" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_4" DATA_TYPE = ASCII_REAL START_BYTE = 236 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_5" DATA_TYPE = ASCII_REAL START_BYTE = 245 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_6" DATA_TYPE = ASCII_REAL START_BYTE = 254 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 6 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_7" DATA_TYPE = ASCII_REAL START_BYTE = 263 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 7 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_8" DATA_TYPE = ASCII_REAL START_BYTE = 272 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 8 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_9" DATA_TYPE = ASCII_REAL START_BYTE = 281 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 9 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_10" DATA_TYPE = ASCII_REAL START_BYTE = 290 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 10 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_11" DATA_TYPE = ASCII_REAL START_BYTE = 299 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 11 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_12" DATA_TYPE = ASCII_REAL START_BYTE = 308 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 12 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_13" DATA_TYPE = ASCII_REAL START_BYTE = 317 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 13 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_14" DATA_TYPE = ASCII_REAL START_BYTE = 326 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 14 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_15" DATA_TYPE = ASCII_REAL START_BYTE = 335 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 15 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CURRENT_ELEVATION_16" DATA_TYPE = ASCII_REAL START_BYTE = 344 BYTES = 8 FORMAT = "F8.3" UNIT = "MICROAMPERE" DESCRIPTION = "Current for elevation step 16" END_OBJECT = COLUMN