/* FSC PREFIX STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "START_TIME" DESCRIPTION = "S/C clock count at frequency scan start." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 21 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "START_FREQUENCY" DESCRIPTION = "Start value of frequency sweep." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 4 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_STEP" DESCRIPTION = "Increment value of frequency sweep." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AC_MAXIMUM" DESCRIPTION = "Max. cantilever signal amplitude detected up to current cycle." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_AT_MAX" DESCRIPTION = "Frequency where the maximum signal signal amplitude was detected." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 4 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_SCANS" DESCRIPTION = "Total number of frequency scan cycles." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_CYCLE" DESCRIPTION = "Current scan cycle number." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 39 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_TIP_NUM" DESCRIPTION = "Selected cantilever [1..8]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 41 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_BLK_NUM" DESCRIPTION = "Selected cantilever block [1..2]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 43 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EXCITATION_LEVEL" DESCRIPTION = "Gain level of piezo-electric actutator used for cantilever excitation [0..7]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 45 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AC_GAIN_LEVEL" DESCRIPTION = "Gain level of cantilever AC signal amplifier [0..7]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 47 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SPARE" DESCRIPTION = "Currently not used." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 49 BYTES = 14 ITEMS = 7 ITEM_BYTES = 2 END_OBJECT = COLUMN