OBJECT = COLUMN NAME = TIME COLUMN_NUMBER = 1 DATA_TYPE = PC_REAL FORMAT = "F16.5" UNIT = SECOND START_BYTE = 1 BYTES = 8 DESCRIPTION = "Time of start of cts data collection. Units are elapsed UTC seconds after 1-Jan-1970 (see EAICD Section 3.2.2). " END_OBJECT = COLUMN OBJECT = COLUMN NAME = GMT_STD COLUMN_NUMBER = 2 DATA_TYPE = TIME FORMAT = "A26" START_BYTE = 9 BYTES = 26 DESCRIPTION = "UTC time of start of cts data collection. Format is yyyy-mm-ddThh:mm:ss.sssssZ where the upper-case T and Z and the colons are delimiters. yyyy is the year mm is the month dd is the day-of-month hh is the hour mm are the minutes and ss.sssss are the seconds." END_OBJECT = COLUMN OBJECT = COLUMN NAME = POWER COLUMN_NUMBER = 3 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 35 BYTES = 2 DESCRIPTION = "Power mode: values 1-6 as described in MIRO User Manual 6.1.2.1.2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = INTEGRATION COLUMN_NUMBER = 4 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 37 BYTES = 2 DESCRIPTION = "Integration mode: values 0-3 as described in MIRO User Manual 6.1.2.1.2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SMOOTHING COLUMN_NUMBER = 5 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 39 BYTES = 2 DESCRIPTION = "Smoothing mode: values 0-3 as described in MIRO User Manual 6.1.2.1.2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CAL COLUMN_NUMBER = 6 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 41 BYTES = 2 DESCRIPTION = "Calibration status: 0=calibration in progress; 1=no calibration in progress (note the non-standard use of 0/1). MIRO calibrated data generated by sw_version=2.0 only contain cal=1 spectra." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LO COLUMN_NUMBER = 7 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 43 BYTES = 2 DESCRIPTION = "Local oscillator mode: values are 0 or 1 as described in MIRO User Manual 6.1.2.1.1. This parameter is only applicable for cal=0 spectra and can be ignored in sw_version=2.0 calibrated MIRO spectra." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ASTEROIDMODE COLUMN_NUMBER = 8 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 45 BYTES = 2 DESCRIPTION = "Asteroid mode: 0=no asteroid mode; 1=asteroid mode in progress." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPECT_T1 COLUMN_NUMBER = 9 DATA_TYPE = PC_REAL FORMAT = "F7.2" UNIT = CELSIUS START_BYTE = 47 BYTES = 8 DESCRIPTION = "CTS Temperature Sensor #1 Branch A." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SW_VERSION COLUMN_NUMBER = 10 DATA_TYPE = PC_REAL FORMAT = "F6.2" START_BYTE = 55 BYTES = 8 DESCRIPTION = "Identifier for MIRO software used to generate this record." END_OBJECT = COLUMN OBJECT = COLUMN NAME = D COLUMN_NUMBER = 11 DATA_TYPE = PC_REAL FORMAT = "F7.2" UNIT = KELVIN START_BYTE = 63 BYTES = 32768 ITEMS = 4096 ITEM_BYTES = 8 INVALID_CONSTANT = -999.00 DESCRIPTION = "Array of antenna temperatures of 4096 CTS bins (see MIRO User Manual Sections 9.2 and 9.5). If no valid calibration parameters are found for this observation, set to -999.00." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IFREQ COLUMN_NUMBER = 12 DATA_TYPE = PC_REAL FORMAT = "F12.5" UNIT = MHz START_BYTE = 32831 BYTES = 32768 ITEMS = 4096 ITEM_BYTES = 8 DESCRIPTION = "Array of intermediate frequencies of 4096 CTS bins. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = D_INTERPFREQ COLUMN_NUMBER = 13 DATA_TYPE = PC_REAL FORMAT = "F7.2" UNIT = KELVIN START_BYTE = 65599 BYTES = 33216 ITEMS = 4152 ITEM_BYTES = 8 INVALID_CONSTANT = -999.00 DESCRIPTION = "Array of antenna temperatures interpolated to a standard intermediate frequency grid of 4152 channels. If no valid calibration parameters are found for this observation, set to -999.00." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IFREQ_INTERP COLUMN_NUMBER = 14 DATA_TYPE = PC_REAL FORMAT = "F12.5" UNIT = MHz START_BYTE = 98815 BYTES = 33216 ITEMS = 4152 ITEM_BYTES = 8 DESCRIPTION = "Array of intermediate frequencies of the 4152-element standard frequency grid. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = ERR_PLL COLUMN_NUMBER = 15 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 132031 BYTES = 2 DESCRIPTION = "Set to 1 when a phase-lock-loop error was detected during data collection. Otherwise set to 0." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ERR_LIMITEDCAL COLUMN_NUMBER = 16 DATA_TYPE = LSB_UNSIGNED_INTEGER FORMAT = "I1" START_BYTE = 132033 BYTES = 2 DESCRIPTION = "Set to 1 when limited calibration data are available. Otherwise set to 0. (See Users Manual Section 9.5.)" END_OBJECT = COLUMN