PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM PRODUCT_ID = "ERRATA.TXT" DATA_SET_ID = "RO-C-OSIWAC-4-ESC2-67P-M17-INFLDSTR-V1.0" OBJECT = TEXT NOTE = "ERRATA file for RO-C-OSIWAC-4-ESC2-67P-M17-INFLDSTR-V1.0" PUBLICATION_DATE = 2019-12-15 END_OBJECT = TEXT END Errata for dataset: RO-C-OSIWAC-4-ESC2-67P-M17-INFLDSTR-V1.0 The IMAGE sub fields FIRST_LINE and FIRST_LINE_SAMPLE can contain negative values. This is in violation of the PDS archive conventions. Negative values are used to identify pixels not coming from the physical CCD but from various diagnostic readout segments. For the generation of the synthetic image used for in-field stray-light correction, updated NAC and WAC frame definitions have been used. To reproduce the results, the following frame definitions must be used in the frame kernel (starting from line 2081 in ROS_V34.TF): \begindata FRAME_ROS_OSIRIS_NAC = -226111 FRAME_-226111_NAME = 'ROS_OSIRIS_NAC' FRAME_-226111_CLASS = 4 FRAME_-226111_CLASS_ID = -226111 FRAME_-226111_CENTER = -226 TKFRAME_-226111_RELATIVE = 'ROS_SPACECRAFT' TKFRAME_-226111_SPEC = 'ANGLES' TKFRAME_-226111_UNITS = 'DEGREES' TKFRAME_-226111_ANGLES = ( 0.01217, 0.03167, 0.0 ) TKFRAME_-226111_AXES = ( 1, 2, 3 ) FRAME_ROS_OSIRIS_WAC = -226112 FRAME_-226112_NAME = 'ROS_OSIRIS_WAC' FRAME_-226112_CLASS = 4 FRAME_-226112_CLASS_ID = -226112 FRAME_-226112_CENTER = -226 TKFRAME_-226112_RELATIVE = 'ROS_SPACECRAFT' TKFRAME_-226112_SPEC = 'ANGLES' TKFRAME_-226112_UNITS = 'DEGREES' TKFRAME_-226112_ANGLES = ( 0.065, -0.417, 0.0 ) TKFRAME_-226112_AXES = ( 1, 2, 3 ) \begintext