OBJECT                           =     COLUMN                                 
   NAME                          =     MOLECULE_FORMULA                       
   DESCRIPTION                   =     "Formula of the molecule.              
                                        Example: 1H2 16O1.  Field is          
                                        left-justified."                      
   DATA_TYPE                     =     CHARACTER                              
   START_BYTE                    =     1                                      
   BYTES                         =     60                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     MOLECULE_NAME                          
   DESCRIPTION                   =     "Name of the molecule.  Example: Water.
                                        Field is left-justified."             
   DATA_TYPE                     =     CHARACTER                              
   START_BYTE                    =     65                                     
   BYTES                         =     40                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     FRAGMENT_FORMULA                       
   DESCRIPTION                   =     "Formula of the molecule fragment.     
                                        Example: 1H1 16O1 +.  Field is        
                                        left-justified."                      
   DATA_TYPE                     =     CHARACTER                              
   START_BYTE                    =     108                                    
   BYTES                         =     60                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     FRAGMENT_MASS                          
   DESCRIPTION                   =     "The molecule fragment mass, including 
                                        the loss of electron(s).  Value is to 
                                        10^-4 precision."                     
   DATA_TYPE                     =     ASCII_REAL                             
   START_BYTE                    =     170                                    
   BYTES                         =     14                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     FRAGMENT_PERCENT                       
   DESCRIPTION                   =     "The abundance of the fragment relative
                                        to the most abundant which is set to  
                                        100%.  Value is to 10^-2 precision."  
   DATA_TYPE                     =     ASCII_REAL                             
   START_BYTE                    =     185                                    
   BYTES                         =     10                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     FRAGMENT_PERCENT_UNC                   
   DESCRIPTION                   =     "The uncertainty in the fragment       
                                        abundance percent.  Value is to 10^-2 
                                        precision."                           
   DATA_TYPE                     =     ASCII_REAL                             
   START_BYTE                    =     196                                    
   BYTES                         =     10                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     SENSITIVITY                            
   DESCRIPTION                   =     "The sensitivity to the parent molecule
                                        .  Value is to 10^-2 precision."      
   DATA_TYPE                     =     ASCII_REAL                             
   START_BYTE                    =     207                                    
   BYTES                         =     10                                     
END_OBJECT                       =     COLUMN                                 
OBJECT                           =     COLUMN                                 
   NAME                          =     SENSITIVITY_UNC                        
   DESCRIPTION                   =     "The uncertainty in the sensitivity.   
                                        Value  is to 10^-2 precision."        
   DATA_TYPE                     =     ASCII_REAL                             
   START_BYTE                    =     218                                    
   BYTES                         =     10                                     
END_OBJECT                       =     COLUMN