ROSETTA ROSINA S/C - DPU Command Description ROS-TUB-MA-07/1.8 Revision 1.8 29.07.2002 Prepared by Thierry Semon, UoB Elsa Montagnon, ESOC Bjoern Fiethe, IDA 1. Document Change Record Rev. Date Pages Description 1.0 22.10.01 All First Issue 1.1 05.11.01 All Update correct database parameter names 1.2 15.11.01 5,6,8, 19,20,22,37,38 Add Enable and SetValue comman 1.3 03.12.01 54 58-91 Add DPU enable GCU command Add higher level DPU commands 1.4 14.12.01 6-10, 22-26, 32-35, 42, 60-73, 76, 85-93 94-100 RSDB changes Add instrument commands 1.5 14.01.02 - Change few parameters according to database im lementation 1.6 17.07.02 All DFMS new commands: ZRND2387, ZRND4100, ZRND420 , ZRND4301, ZRND4302, ZRND4304, ZRND4308, ZRND4310, ZRND4400, ZRND4600, ZRND50 1, ZRND5201, ZRND5209, ZRND5212, ZRND521B, ZRND5224, ZRND522D DFMS change parameters of ZRND1202, ZRND2101, ZRND2307 RTOF new commands: ZRNR221F, ZRNR2220, ZRNR2221, ZRNR2222, ZRNR2223, ZRNR23C5, ZRNR4100, ZRNR4301, ZRNR4302, ZRNR4304, ZRNR4308, ZRNR4310, ZRNR4400, ZRNR4600 ZRNR5001, ZRNR5201, ZRNR5209, ZRNR5212, ZRNR521B, ZRNR5224, ZRNR522D RTOF change parameters of ZRNR1202, ZRNR2101, ZRNR2303, ZRNR2383, ZRNR2306, ZR R230A, ZRNR230B, ZRNR230C, ZRNR238C RTOF replace Gas/Ion by SS/OS COPS new commands: ZRNC2306, ZRNC2307, ZRNC4100, ZRNC4301, ZRNC4302, ZRNC4304, ZRNC4308, ZRNC4310, ZRNC4400, ZRNC4600 COPS change parameters of ZRNC1201, ZRNC2100, ZRNC2303, ZRNC2304 DPU new command: ZRNP350D DPU change parameters of ZRNP2502, ZRNP3507, ZRNP3508, ZRNP4001 1.7 23.07.02 RTOF Change parameters for database implementation f following cmds: ZRNR2303, ZRNR2383, ZRNR23C5, ZRNR2306 Change parameter naming of following calcurves: CRNVR101, CRNVR102 1.8 29.07.02 DFMS, RTOF Change command name from ZRNX1202, ZRN 2101 to ZRNX1211, ZRNX2110 to be consistent with database 2. Reference Documentation Document Name Document Number Revision RD[1] DPU Housekeeping Reports ROS-TUB-SP-02/2.4 04.07.2001 RD[2] DPU Science Data Packets ROS-TUB-SP-03/1.1 01.09.2000 RD[3] S/C - DPU Command Packets ROS-TUB-SP-04/2.2 04.07.2001 RD[4] DPU Event Packets ROS-TUB-SP-05/2.3 04.07.2001 RD[5] DPU Memory Management Services ROS-TUB-SP-06/1.3 14.07.2000 RD[6] DPU Context Transfer Service ROS-TUB-SP-07/1.0 10.07.2001 RD[7] Rosina Mode Change Commands ROS-TUB-MA-05/2.2 23.08.2001 3. Sensor Commands 3.1 DFMS Type No. Name RSDB Serv Sub- Serv Param Count Enable Short Description D1 D1_Direct ZRND1001 196 1 1 X Direct DFMS Command D2 D_Enable ZRND1002 196 2 2 Enable Critical Command D10 D2_SetValue ZRND2001 196 10 4 X Set & erify Value D11 D2_Execute ZRND2002 196 11 1 Execut single Command D12 D2_Function ZRND2003 196 12 5 Call F nction D33 D3_Acquisition ZRND3004 196 33 5 Acquis tion & Readout D50 D4_Mode ZRND4001 196 50 8 Set & Operate ingle Mode D51 D4_ScanMode ZRND4002 196 51 10 Operat Scan Mode D52 D4_LoadLUT ZRND4003 196 52 5..79 X Load L ok Up Table D53 D4_SetConv ZRND4004 196 53 16 X Set Co version Parameter D55 D4_LoadMode ZRND4006 196 55 26 X Load M de Settings D70 D5_Sequence ZRND5001 196 70 5 Measur ment Sequence D71 D5_LoadSeq ZRND5002 196 71 6..177 X Load S quence Table 3.1.1 ZRND1001 (D1_Direct) Telecommand Packet Information Packet Name ZRND1001 Instrument ROSINA Packet Description D1_Direct Packet Function Any three byte low-level command can be sent directly o the DFMS (see RD[3] and sensor documentation) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 01 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG101 Command 4 octet Contains 2 detailed parameters: PRNDG101 Spare 1 octet 0 PRNDG102 Sensor Command 3 octet DFMS low-level command code Notes: For security, an enable command (ZRND1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. 3.1.2 ZRND1002 (D_Enable) Telecommand Packet Information Packet Name ZRND1002 Instrument ROSINA Packet Description D_Enable Packet Function Enable critical command (enable column marked in table 3.1) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG102 Subservice 2 octet Contains 2 detailed parameters: PRNDG103 Spare 1 octet 0 PRNDG104 Subservice of critical cmd 1 octet e.g. 1 for ZRND1001 PRNGG103 Opcode of critical cmd 2 octet First two bytes of parameters e.g. spare 0 and first byte of sensor cmd for ZRND1001) Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRND12F8 Instrument ROSINA Packet Description D_Enable OD_COVER Packet Function Enable DFMS cover command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cover cmd 2 octet Fixed field set to 12 N/A Opcode of cover cmd 2 octet Fixed field set to 8 Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRND1201 Instrument ROSINA Packet Description D_Enable SetValue (voltage 1 to 32) Packet Function Enable DFMS SetValue command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cmd 2 octet Fixed field set to 10 PRNGD101 Set Voltage No. 2 octet Limit set LRND0101: [1; 32] Calcurve CRNVD101: MCPFront = 1 MCPBack = 2 HVFDP = 3 ISCIRP1 = 4 ISCIRP2 = 5 ISCISP = 6 ISCTLL = 7 ISCTLR = 8 MEPHVACC = 9 ASPESS1 = 10 ASPESS2 = 11 ASPRQ = 12 ASPHP = 13 ASPMP = 14 ASPZ1Q = 15 ASPZ2Q = 16 ASPESAC = 17 ASPESAO = 18 ASPESAI = 19 ASPESAO2 = 20 ASPESAI2 = 21 ASPESAO3 = 22 ASPESAI3 = 23 ASPESAO4 = 24 ASPESAI4 = 25 ASPESAO5 = 26 ASPESAI5 = 27 CEMREP = 28 ISCSLL = 29 ISCSLR = 30 ISCSES = 31 ISCSEB = 32 Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRND1211 Instrument ROSINA Packet Description D_Enable SetValue (voltage 33 to 43) Packet Function Enable DFMS SetValue command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cmd 2 octet Fixed field set to 10 PRNGD102 Set Voltage No. 2 octet Limit set LRND0102: [33; 43] Calcurve CRNVD102: ASPHVBIAS = 33 MEPHVCEM = 34 FDPADCOFF = 35 ISCERP = 36 ISCF1BIAS = 37 ISCF2BIAS = 38 FDPFCOFF = 39 MEPMG = 40 MEPISB = 41 ISCFI1EM = 42 ISCFI2EM = 43 Notes: One enable is valid until another enable command is sent. 3.1.3 ZRND2001 (D2_SetValue) Telecommand Packet Information Packet Name ZRND2001 Instrument ROSINA Packet Description D2_SetValue Packet Function Set any DFMS internal voltage or parameter with the DP general voltage set function (taking into account required stepping and monit ring, e.g. DFMS MCP Front) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG201 Parameter No. 2 octet Entry of set parameter in DPU cmd conv rsion table PRNGG202 Parameter Value 4 octet Set value in floating point PRNGG203 Wait time in ms 2 octet Optional wait time for HK monitoring a ter cmd was sent PRNGG204 Monitoring No. 2 octet Optional entry of related HK parameter in DPU monitoring table Notes: Optional parameters will overwrite existing DPU internal parameters. F r security, an enable command (ZRND1002) has to be sent before the command wil be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRND2100 Instrument ROSINA Packet Description D2_SetValue DFMS voltage (voltage 1 to 32) Packet Function Set predefined DFMS internal voltages with the DPU gen ral voltage set function (taking into account required stepping and monitoring Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD101 Set Voltage No. 2 octet Calcurve CRNVD101: MCPFront = 1 MCPBack = 2 HVFDP = 3 ISCIRP1 = 4 ISCIRP2 = 5 ISCISP = 6 ISCTLL = 7 ISCTLR = 8 MEPHVACC = 9 ASPESS1 = 10 ASPESS2 = 11 ASPRQ = 12 ASPHP = 13 ASPMP = 14 ASPZ1Q = 15 ASPZ2Q = 16 ASPESAC = 17 ASPESAO = 18 ASPESAI = 19 ASPESAO2 = 20 ASPESAI2 = 21 ASPESAO3 = 22 ASPESAI3 = 23 ASPESAO4 = 24 ASPESAI4 = 25 ASPESAO5 = 26 ASPESAI5 = 27 CEMREP = 28 ISCSLL = 29 ISCSLR = 30 ISCSES = 31 ISCSEB = 32 PRNGD103 Voltage Value 4 octet Set value in floating point N/A Wait time in ms 2 octet Fixed field set to 0 N/A Monitoring No. 2 octet Fixed field set to 0 Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRND2110 Instrument ROSINA Packet Description D2_SetValue DFMS voltage (voltage 33 to 43) Packet Function Set predefined DFMS internal voltages with the DPU gen ral voltage set function (taking into account required stepping and monitoring Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD102 Set Voltage No. 2 octet Calcurve CRNVD102: ASPHVBIAS = 33 MEPHVCEM = 34 FDPADCOFF = 35 ISCERP = 36 ISCF1BIAS = 37 ISCF2BIAS = 38 FDPFCOFF = 39 MEPMG = 40 MEPISB = 41 ISCFI1EM = 42 ISCFI2EM = 43 PRNGD103 Voltage Value 4 octet Set value in floating point N/A Wait time in ms 2 octet Fixed field set to 0 N/A Monitoring No. 2 octet Fixed field set to 0 Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Internal use only. 3.1.4 ZRND2002 (D2_Execute) Telecommand Packet Information Packet Name ZRND2200 Instrument ROSINA Packet Description D2_Init (D2_Execute) Packet Function Set all DFMS voltages to initial values Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_Init 2 octet Fixed field set to 0 Notes: Telecommand Packet Information Packet Name ZRND2204 Instrument ROSINA Packet Description D2_ISHeat_test (D2_Execute) Packet Function Test DFMS ion source heater (10W) by switching it on f r 10s Generation Rules All DFMS HV shall be OFF and disabled. Controlled high vacuum (< 6 x 10-7 mbar) has to be inside DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_ISHeat_test 2 octet Fixed field set to 4 Notes: Command is used for ground tests only. Telecommand Packet Information Packet Name ZRND2205 Instrument ROSINA Packet Description D2_RDPHeat_test (D2_Execute) Packet Function Test DFMS remote detector package heater by switching t on for 30s Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_RDPHeat 2 octet Fixed field set to 5 Notes: Command is used for ground tests only. Telecommand Packet Information Packet Name ZRND2212 Instrument ROSINA Packet Description D2_Heat_Off (D2_Execute) Packet Function Switch off both ion source and RDP heater Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_Heat_Off 2 octet Fixed field set to 12 Notes: Telecommand Packet Information Packet Name ZRND2213 Instrument ROSINA Packet Description D2_ISHeat_On (D2_Execute) Packet Function Switch on DFMS ion source heater (10 W) for cleaning Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_ISHeat_On 2 octet Fixed field set to 13 Notes: Telecommand Packet Information Packet Name ZRND2215 Instrument ROSINA Packet Description D2_EnaHV (D2_Execute) Packet Function Enable HV (clear HV safe) Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A D2_EnaHV 2 octet Fixed field set to 15 Notes: 3.1.5 ZRND2003 (D2_Function) Telecommand Packet Information Packet Name ZRND2301 Instrument ROSINA Packet Description OD_READLEDA (D2_Function) Packet Function Read DFMS LEDA detector and send science data to S/C Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OD_READLEDA 2 octet Fixed field set to 1 PRNGD201 Number of cycles 4 octet Contains 3 detailed parameters PRNDD220 Spare 2 octet Not modifiable, set to 0 PRNDD221 Number of pre-cycles 4 bits Default: 2 PRNDD222 Number of cycles 12 bits Number of LEDA accumulation cy les PRNGD202 Wait time and sci mode 4 octet Contains 3 detailed parameters PRNDD223 Repetitive readout/Wait time 24 bits 0x8XXXXX + wait time i ms (0 = no repetition) PRNDD225 Science mode 1 octet Type of science packets PRNGD203 Integration time 4 octet LEDA integration time in ms fo one cycle PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRND2302 Instrument ROSINA Packet Description OD_RESSCI (D2_Function) Packet Function Reset DFMS science readout Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OD_RESSCI 2 octet Fixed field set to 2 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRND2303 Instrument ROSINA Packet Description OD_MCPINIT (D2_Function) Packet Function Step up MCP high voltages from current value (normally 0) to the default value to activate the DFMS MCP detector. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Steps up MCP HVs 2 octet Fixed field set to 3 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRND2304 Instrument ROSINA Packet Description OD_MCPDOWN (D2_Function) Packet Function Step down MCP High Voltages from the current value to to deactivate the DFMS MCP detector. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Steps down MCP HVs 2 octet Fixed field set to 4 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRND2305 Instrument ROSINA Packet Description OD_GENHV Enable (D2_Function) Packet Function Enable and set basic DFMS high voltages Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A HV + Fil Ops 2 octet Fixed field set to 5 N/A HV + Fil Enable 4 octet Fixed field set to 1 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Function clears HV_Safe bit and sets Cover_Disable bit. Telecommand Packet Information Packet Name ZRND2385 Instrument ROSINA Packet Description OD_GENHV Disable (D2_Function) Packet Function Reset basic DFMS high voltages to 0 and disable them Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A HV + Fil Ops 2 octet Fixed field set to 5 N/A HV + Fil Disable 4 octet Fixed field set to 14 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Function clears HV_Safe bit and sets Cover_Disable bit. Telecommand Packet Information Packet Name ZRND2307 Instrument ROSINA Packet Description OD_GAINADJ On (D2_Function) Packet Function Start DFMS MCP gain adjustment (set optimal MCP HVs). Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A MCP Gain Adjust 2 octet Fixed field set to 7 N/A On 4 octet Fixed field set to 1 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRND2387 Instrument ROSINA Packet Description OD_GAINADJ Off (D2_Function) Packet Function Stop DFMS MCP gain adjustment (set optimal MCP HVs). Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A MCP Gain Adjust 2 octet Fixed field set to 7 N/A Off 4 octet Fixed field set to 14 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRND23F8 Instrument ROSINA Packet Description OD_COVER (D2_Function) Packet Function Operate DFMS cover motor after pyro fired Generation Rules DO NOT USE ON GROUND! Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A DFMS Cover Ops 2 octet Fixed field set to 8 PRNGD250 Cover motor parameter 4 octet Contains 6 detailed parameters PRNDD228 Spare 4 bits Not modifiable, set to 0 PRNDD229 Cover low voltage set 4 bits Default: 2 PRNDD230 Cover acceleration 4 bits Default: 1 PRNDD231 Cover brake 4 bits Default: 7 PRNDD232 Cover min. speed 1 octet Default: 4 PRNDD233 Cover max. speed 1 octet Default: 1 PRNGD251 Cover action and mode 4 octet Contains 5 detailed parameters PRNDD234 Spare 12 bits Not modifiable, set to 0 PRNDD235 Cover action 1 octet Calcurve CRNVD210 48 = Cover reset (open cover) 192 = Check last move complete 1 = Close cover to end switch 2 = Open cover to end switch 4 = Move cover to absolute Pos. (default) 8 = Move cover relative steps PRNDD236 Cover mode 2 bits Calcurve CRNVD211 0 = Micro step 1 = Nominal (default) 2 = Hall PRNDD237 Cover direction 2 bits Calcurve CRNVD212 0 = Close 2 = Open PRNDD238 Cover position/steps 1 octet Limit set LRND0238 Allowed range: 0 (open) - 160 (close), TBC PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: SHALL NOT BE USED ON GROUND. For security, an enable command (ZRND1002) has to be sent before the command w ll be accepted by DPU. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRND230A Instrument ROSINA Packet Description OD_CEMSCAN (D2_Function) Packet Function Setup all voltages for given mass (CEM/FC/LEDA), perfo m CEM/FC Scan, and send science data to S/C (CEM/FC). Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A CEM-LEDA-FC scan 2 octet Fixed field set to 10 PRNGD204 Steps for noise readout 2 octet Number of steps taken for back ground noise readout (default = 0) PRNGD205 Mass Shift 2 octet Shift for center of mass in 1/100 % (d fault = 0) PRNGD206 Scan Action 2 octet Contains 4 detailed parameters: PRNDD201 D-Spare1 12 bits Not modifiable, set to 0 PRNDD202 ESA/VACC Scan (only valid for high resolution) 1 bit Calcurve CRNVD201 0 = VACCL Scan 1 = ESA Scan PRNDD203 CEM/FC/LEDA selection 2 bits Calcurve CRNVD202 0 = CEM 1 = LEDA 2 = FC PRNDD204 High/Low Resolution 1 bit Calcurve CRNVD203 0 = Low 1 = High PRNGD207 CEM accumulation time 2 octet Time in 0.513ms steps PRNGD208 Mass 4 octet Floating point PRNGD209 Zoom 4 octet Floating point (default = 1) Notes: For LEDA MCP HVs have to be stepped up with command ZRND2303 before. Telecommand Packet Information Packet Name ZRND230B Instrument ROSINA Packet Description OD_ABORT (D2_Function) Packet Function Abort all DFMS functions. Generation Rules Emergency use only. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Abort functions 2 octet Fixed field set to 11 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRND230C Instrument ROSINA Packet Description OD_FILA On (D2_Function) Packet Function Setup all needed voltages and switch-on DFMS filament. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Filament Operation 2 octet Fixed field set to 12 PRNGD210 DFMS Filament Settings 4 octet Contains 5 detailed parameters PRNDD210 D-Spare2 24 bits Not modifiable, set to 0 PRNDD211 Filament ON 4 bits Not modifiable, set to 1 PRNDD212 D-Spare3 1 bit Not modifiable, set to 0 PRNDD213 Filament emission 2 bits Calcurve CRNVD205 0 = 2uA 1 = 20uA 2 = SUB 3 = 200uA PRNDD214 Filament selection 1 bit Calcurve CRNVD206 0 = Filament 1 1 = Filament 2 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRND238C Instrument ROSINA Packet Description OD_FILA Off (D2_Function) Packet Function Switch-off DFMS filament and reset voltages. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Filament Operation 2 octet Fixed field set to 12 PRNGD211 DFMS Filament Settings 4 octet Contains 3 detailed parameters PRNDD215 D-Spare2 24 bits Not modifiable, set to 0 PRNDD216 Filament OFF 4 bits Not modifiable, set to 14 PRNDD217 D-Spare4 4 bits Not modifiable, set to 0 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRND230D Instrument ROSINA Packet Description OD_RESETVOLT (D2_Function) Packet Function Reset all scan voltages of DFMS used in function ZRND2 0A except MCP HVs. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Reset DFMS scan voltages 2 octet Fixed field set to 13 PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: To disable all HVs, function ZRND2385 has to be called afterwards 3.1.6 ZRND3004 (D3_Acquisition) Same functionality and parameters as ZRND2003 (D2_Function). 3.1.7 ZRND4001 (D4_Mode) Telecommand Packet Information Packet Name ZRND4100 Instrument ROSINA Packet Description D4_Mode Packet Function Setup and operate single mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 50 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG401 Mode No. 2 octet Number of mode (see DFMS measurement m des docu) PRNGG402 Mass 2 octet Set single mass (0 = default, use mass from mo e entry) PRNGD401 Cycles 2 octet Number of repetition cycles for mode (default 0) PRNGD402 Mass Shift 2 octet Shift for center of mass in 1/100 % (d fault = 0) PRNGD202 Wait time and sci mode 4 octet Contains 3 detailed parameters PRNDD223 Repetitive readout/Wait time 24 bits 0x8XXXXX + wait time i ms (0 = no repetition) PRNDD225 Science mode 1 octet Type of science packets (default = 0) PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: 3.1.8 ZRND4002 (D4_ScanMode) Telecommand Packet Information Packet Name ZRND4200 Instrument ROSINA Packet Description D4_ScanMode Packet Function Setup and operate mass-scan mode (reference, start..st p, reference) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 51 Structure ID Packet length 44 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG409 Mode No. 2 octet Number of mode (see DFMS measurement m des docu) PRNGG40A Reference Mass 2 octet Set reference mass (0 = default, use m ss from mode entry) PRNGG40B Start Mass 2 octet Set start mass (0 = default, use mass rom mode entry) PRNGG40C Stop Mass 2 octet Set stop mass (0 = default, use mass f om mode entry) PRNGD401 Cycles 2 octet Number of repetition cycles for mode (default 0) PRNGD402 Mass Shift 2 octet Shift for center of mass in 1/100 % (d fault = 0) PRNGD202 Wait time and sci mode 4 octet Contains 3 detailed parameters PRNDD223 Repetitive readout/Wait time 24 bits 0x8XXXXX + wait time i ms (0 = no repetition) PRNDD225 Science mode 1 octet Type of science packets (default = 0) PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGD200 DFMS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: 3.1.9 ZRND4003 (D4_LoadLUT) Telecommand Packet Information Packet Name ZRND4301 Instrument ROSINA Packet Description D4_LoadLUT 1 word Packet Function Load 1 word in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 52 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD407 Table No. 1 octet Calcurve CRNVD103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x12: STMCP (DFMS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x30: D3MCP 0x31: D3MCEM 0x32: D3MOT 0x33: D3ESA 0x34: D3CEM 0x35: D3LEDA 0x36: D3FC 0x37: DMCPG 0x38: DMCPI 0x39: DMASS 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGD403 Parameter 4 octet Table parameter PRNGD404 DFMS PAD-16 bits 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND4302 Instrument ROSINA Packet Description D4_LoadLUT 2 words Packet Function Load 2 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 52 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD407 Table No. 1 octet Calcurve CRNVD103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x12: STMCP (DFMS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x30: D3MCP 0x31: D3MCEM 0x32: D3MOT 0x33: D3ESA 0x34: D3CEM 0x35: D3LEDA 0x36: D3FC 0x37: DMCPG 0x38: DMCPI 0x39: DMASS 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 2 PRNGD403 Parameter 2 * 4 octet Table parameter PRNGD404 DFMS PAD-16 bits 2 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND4304 Instrument ROSINA Packet Description D4_LoadLUT 4 words Packet Function Load 4 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 52 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD407 Table No. 1 octet Calcurve CRNVD103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x12: STMCP (DFMS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x30: D3MCP 0x31: D3MCEM 0x32: D3MOT 0x33: D3ESA 0x34: D3CEM 0x35: D3LEDA 0x36: D3FC 0x37: DMCPG 0x38: DMCPI 0x39: DMASS 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 4 PRNGD403 Parameter 4 * 4 octet Table parameter PRNGD404 DFMS PAD-16 bits 4 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND4308 Instrument ROSINA Packet Description D4_LoadLUT 8 words Packet Function Load 8 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 52 Structure ID Packet length 64 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD407 Table No. 1 octet Calcurve CRNVD103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x12: STMCP (DFMS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x30: D3MCP 0x31: D3MCEM 0x32: D3MOT 0x33: D3ESA 0x34: D3CEM 0x35: D3LEDA 0x36: D3FC 0x37: DMCPG 0x38: DMCPI 0x39: DMASS 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 8 PRNGD403 Parameter 8 * 4 octet Table parameter PRNGD404 DFMS PAD-16 bits 8 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND4310 Instrument ROSINA Packet Description D4_LoadLUT 16 words Packet Function Load 16 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 52 Structure ID Packet length 112 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGD407 Table No. 1 octet Calcurve CRNVD103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x12: STMCP (DFMS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x30: D3MCP 0x31: D3MCEM 0x32: D3MOT 0x33: D3ESA 0x34: D3CEM 0x35: D3LEDA 0x36: D3FC 0x37: DMCPG 0x38: DMCPI 0x39: DMASS 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGD403 Parameter 16 * 4 octet Table parameter PRNGD404 DFMS PAD-16 bits 16 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. 3.1.10 ZRND4004 (D4_SetConv) Telecommand Packet Information Packet Name ZRND4400 Instrument ROSINA Packet Description D4_SetConv Packet Function Set entry of DFMS command conversion table [stConvTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 53 Structure ID Packet length 68 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG480 Table No. 2 octet pointer to table (default = 0, dummy = 0xFFFF) PRNGG416 Parameter No. 2 octet pointer to parameter entry PRNGD405 Function/Shift 2 octet Contains 3 detailed parameters: PRNDD401 Type 2 bits Type of calculation (default = 0) PRNDD402 Function 8 bits Calc. function Calcurve CRNVD104: 0 = Default 1 = DF_INVMSB 64 = XF_ACTIVE 128 = XF_DOUBLE PRNDD403 Shift 6 bits Shift command value (none = 0, left = 1..31, right = 32..63) PRNGG418 Mask 2 octet AND mask PRNGG419 Default 4 octet OR mask PRNGG41A Parameter Value 1 4 octet multiplier (floating point) PRNGG41B Parameter Value 2 4 octet offset (floating point) PRNGG41C Monitoring 2 octet monitoring function no. (default = 0) PRNGG41D Wait 2 octet wait time for monitoring in ms PRNGG41E Parameter Value 3 4 octet step width (floating point, de . = 0) PRNGG48B Sleep 2 octet Sleep time for steps in ms PRNGG48C Spare 2 octet Entry of switch command table (default = 0) PRNGG41F Parameter Value 4 4 octet Absolute min. limit (floating oint, default = 0) PRNGG481 Parameter Value 5 4 octet Absolute max. limit (floating oint, default = 0) PRNGG482 HK Cmd 1 4 octet sensor cmd for hk read (default = 0) PRNGG483 HK Cmd 2 4 octet sensor cmd for hk read PRNGG484 HK Cmd 3 4 octet sensor cmd for hk read PRNGG485 HK Cmd 4 4 octet sensor cmd for hk read Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. 3.1.11 ZRND4006 (D4_LoadMode) Telecommand Packet Information Packet Name ZRND4600 Instrument ROSINA Packet Description D4_LoadMode Packet Function Load entry of DFMS mode table [stModeMainTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 55 Structure ID Packet length 80 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG421 Mode No. 2 octet Mode entry in table (0xFFFF = dummy) PRNGG422 Func/Task 2 octet Contains 2 detailed parameters: PRNDG406 Function 1 octet Configuration (gas/ion/off) PRNDG407 Task 1 octet Function (com/noi/opt/cal) PRNGG423 Parameter Value 1 4 octet Ion U1 (floating point) PRNGG424 Parameter Value 2 4 octet Ion U2 (floating point PRNGG425 Parameter Value 3 4 octet Ion U3 (floating point) PRNGG426 Parameter Value 4 4 octet Ion U4 (floating point) PRNGG427 Emi/Res 2 octet Contains 2 detailed parameters: PRNDG408 Emission 1 octet Emission (off/sub/low/med/hi) PRNDG409 Resolution 1 octet Sensor resolution (low/hi) and electro energy (low/hi/var) PRNGG486 Filament 2 octet Filament selection PRNGG428 Electr. Energy 1 4 octet Var. energy U1 (floating point PRNGG429 Electr. Energy 2 4 octet Var. energy U2 (floating point PRNGG42A Zoom 4 octet Zoom factor (floating point) PRNGG487 Position 2 octet Start/stop cover positions (0 = no move) PRNGG42B Detector 6 octet Contains 5 detailed parameters: PRNDG40C Detector 1 octet Detector and range selection (MCP/CEM/FAR) PRNDG40E Not used 1 octet Not used, set to 0 PRNDG40D Det. Integration 2 octet Detector integration time PRNDG40F Det. Configuration 1 octet Detector configuration PRNDG410 Det. Gain 1 octet Detector gain selection PRNGG42C Mass Value 1 2 octet Not used, set to 0 PRNGG42D Mass Value 2 2 octet Start mass or mass table entry PRNGG42E Mass Value 3 2 octet Not used, set to 0 PRNGG42F Mass Value 4 2 octet Stop mass PRNGG430 Mass Value 5 2 octet Not used, set to 0 PRNGG431 Mass Value 6 2 octet Reference mass PRNGG432 Mass Value 7 2 octet Not used, set to 0 PRNGG433 Mass Value 8 2 octet Not used, set to 0 PRNGG434 Mass Value 9 2 octet Not used, set to 0 PRNGG435 Mass Value 10 2 octet Not used, set to 0 PRNGD406 Comp/Accu 4 octet Contains 2 detailed parameters: PRNDD404 Compression 2 octet Data compression parameter PRNDD405 Accumulation 2 octet Number of detector accumulations Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. 3.1.12 ZRND5001 (D5_Sequence) Telecommand Packet Information Packet Name ZRND5001 Instrument ROSINA Packet Description D5_Sequence Packet Function Execute DFMS mode sequence Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 70 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG501 Sequence no. 2 octet Entry of DFMS sequence table to execut (0xFFFF = dummy) PRNGG503 Parameter Value 1 4 octet Parameter transferred to funct ons called in sequence table PRNGG504 Parameter Value 2 4 octet Parameter transferred to funct ons called in sequence table PRNGG505 Parameter Value 3 4 octet Parameter transferred to funct ons called in sequence table (FP) PRNGG506 Parameter Value 4 4 octet Parameter transferred to funct ons called in sequence table (FP) Notes: 3.1.13 ZRND5002 (D5_LoadSeq) Telecommand Packet Information Packet Name ZRND5201 Instrument ROSINA Packet Description D5_LoadSeq 1 word Packet Function Load 1 word to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 20 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 1 PRNGG508 Parameter Value 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND5209 Instrument ROSINA Packet Description D5_LoadSeq 1 entry Packet Function Load 1 entry to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 52 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 9 PRNGG508 Parameter Value 9 * 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND5212 Instrument ROSINA Packet Description D5_LoadSeq 2 entries Packet Function Load 2 entries to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 88 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 18 PRNGG508 Parameter Value 18 * 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND521B Instrument ROSINA Packet Description D5_LoadSeq 3 entries Packet Function Load 3 entries to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 124 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 27 PRNGG508 Parameter Value 27 * 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND5224 Instrument ROSINA Packet Description D5_LoadSeq 4 entries Packet Function Load 4 entries to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 160 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 36 PRNGG508 Parameter Value 36 * 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRND522D Instrument ROSINA Packet Description D5_LoadSeq 5 entries Packet Function Load 5 entries to DFMS mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 196 Service Subtype 71 Structure ID Packet length 196 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 45 PRNGG508 Parameter Value 45 * 4 octet Table parameter/command Notes: For security, an enable command (ZRND1002) has to be sent before the c mmand will be accepted by DPU. 3.2 RTOF Type No. Name RSDB Serv Sub- serv Param Count Enable Description R1 R1_Direct ZRNR1001 200 1 1 X Direct RTOF Command R2 R_Enable ZRNR1002 200 2 2 Enable Critical Command R10 R2_SetValue ZRNR2001 200 10 4 X Set & erify Value R11 R2_Execute ZRNR2002 200 11 1 Execut single Command R12 R2_Function ZRNR2003 200 12 5 Call F nction R33 R3_Acquisition ZRNR3004 200 33 5 Acquis tion & Readout R50 R4_Mode ZRNR4001 200 50 8 Set & Operate ingle Mode R52 R4_LoadLUT ZRNR4003 200 52 5..79 X Load L ok Up Table R53 R4_SetConv ZRNR4004 200 53 16 X Set Co version Parameter R55 R4_LoadMode ZRNR4006 200 55 26 X Load M de Settings R70 R5_Sequence ZRNR5001 200 70 5 Measur ment Sequence R71 R5_LoadSeq ZRNR5002 200 71 6..177 X Load S quence Table 3.2.1 ZRNR1001 (R1_Direct) Telecommand Packet Information Packet Name ZRNR1001 Instrument ROSINA Packet Description R1_Direct Packet Function Any three byte low-level command can be sent directly o the RTOF (see RD[3] and sensor documentation) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 01 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG101 Command 4 octet Contains 2 detailed parameters: PRNDG101 Spare 1 octet Not modifiable, set to 0 PRNDG102 Sensor Command 3 octet RTOF low-level command code Notes: For security, an enable command (ZRNR1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. 3.2.2 ZRNR1002 (R_Enable) Telecommand Packet Information Packet Name ZRNR1002 Instrument ROSINA Packet Description R_Enable Packet Function Enable critical command (enable column marked in table 3.2) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG102 Subservice 2 octet Contains 2 detailed parameters: PRNDG103 Spare 1 octet Not modifiable, set to 0 PRNDG104 Subservice of critical cmd 1 octet e.g. 1 for ZRNR1001 PRNGG103 Opcode of critical cmd 2 octet First two bytes of parameters e.g. spare 0 and first byte of sensor cmd for ZRNR1001) Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRNR12F8 Instrument ROSINA Packet Description R_Enable OR_COVER Packet Function Enable RTOF cover command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cover cmd 2 octet Fixed field set to 12 N/A Opcode of cover cmd 2 octet Fixed field set to 8 Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRNR1201 Instrument ROSINA Packet Description R_Enable SetValue (voltages 1 to 29) Packet Function Enable RTOF SetValue command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cmd 2 octet Fixed field set to 10 PRNGR101 Set Voltage No. 2 octet Limit set LRNR0101: [1; 29] Calcurve CRNVR101: 40V = 1 70V = 2 BP_SS = 3 BP_OS = 4 E2_OS = 5 ELA_OS = 6 ELB_OS = 7 GR_SS = 8 GR_OS = 9 P_OS = 10 P_SS = 11 HM2 = 12 HM3 = 13 M_SS = 14 M_OS = 15 A1_SS = 16 A1_OS = 17 A2_SS = 18 A2_OS = 19 D = 20 HM1 = 21 HML = 22 R1 = 23 R2 = 24 RL = 25 SL_SS = 26 SL_OS = 27 FIL_SS = 28 FIL_OS = 29 Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRNR1211 Instrument ROSINA Packet Description R_Enable SetValue (voltages 30 to 43) Packet Function Enable RTOF SetValue command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cmd 2 octet Fixed field set to 10 PRNGR102 Set Voltage No. 2 octet Limit set LRNR0102: [30; 45] Calcurve CRNVR102: REPA_SS = 30 REPA_OS = 31 REPB_SS = 32 REPB_OS = 33 TRAP = 34 ENT1_OS = 35 EC1_SS = 36 EC1_OS = 37 EH1_SS = 38 EH1_OS = 39 MCC_OS = 40 MCC_SS = 41 HMPW = 42 HMPD = 43 ETSDEL = 44 ETLDEL = 45 Notes: One enable is valid until another enable command is sent. 3.2.3 ZRNR2001 (R2_SetValue) Telecommand Packet Information Packet Name ZRNR2001 Instrument ROSINA Packet Description R2_SetValue Packet Function Set any RTOF internal voltage or parameter with the DP general voltage set function (taking into account required stepping and monit ring, e.g. RTOF Drift) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG201 Parameter No. 2 octet Entry of set parameter in DPU cmd conv rsion table PRNGG202 Parameter Value 4 octet Set value in floating point PRNGG203 Wait time in ms 2 octet Optional wait time for HK monitoring a ter cmd was sent PRNGG204 Monitoring No. 2 octet Optional entry of related HK parameter in DPU monitoring table Notes: Optional parameters will overwrite existing DPU internal parameters. F r security, an enable command (ZRNR1002) has to be sent before the command wil be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNR2100 Instrument ROSINA Packet Description R2_SetValue RTOF Voltage (voltage 1 to 29) Packet Function Set predefined RTOF internal voltages with the DPU gen ral voltage set function (taking into account required stepping and monitoring Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR101 Set Voltage No. 2 octet Calcurve CRNVR101: 40V = 1 70V = 2 BP_SS = 3 BP_OS = 4 E2_OS = 5 ELA_OS = 6 ELB_OS = 7 GR_SS = 8 GR_OS = 9 P_OS = 10 P_SS = 11 HM2 = 12 HM3 = 13 M_SS = 14 M_OS = 15 A1_SS = 16 A1_OS = 17 A2_SS = 18 A2_OS = 19 D = 20 HM1 = 21 HML = 22 R1 = 23 R2 = 24 RL = 25 SL_SS = 26 SL_OS = 27 FIL_SS = 28 FIL_OS = 29 PRNGR103 Voltage Value 4 octet Set value in floating point N/A Wait time in ms 2 octet Fixed field set to 0 N/A Monitoring No. 2 octet Fixed field set to 0 Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNR2110 Instrument ROSINA Packet Description R2_SetValue RTOF Voltage (voltages 30 to 43) Packet Function Set predefined RTOF internal voltages with the DPU gen ral voltage set function (taking into account required stepping and monitoring Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR102 Set Voltage No. 2 octet Calcurve CRNVR102: REPA_SS = 30 REPA_OS = 31 REPB_SS = 32 REPB_OS = 33 TRAP = 34 ENT1_OS = 35 EC1_SS = 36 EC1_OS = 37 EH1_SS = 38 EH1_OS = 39 MCC_OS = 40 MCC_SS = 41 HMPW = 42 HMPD = 43 ETSDEL = 44 ETLDEL = 45 PRNGR103 Voltage Value 4 octet Set value in floating point N/A Wait time in ms 2 octet Fixed field set to 0 N/A Monitoring No. 2 octet Fixed field set to 0 Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Internal use only. 3.2.4 ZRNR2002 (R2_Execute) Telecommand Packet Information Packet Name ZRNR2200 Instrument ROSINA Packet Description R2_Init (R2_Execute) Packet Function Set all RTOF voltages to initial values Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_Init 2 octet Fixed field set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2206 Instrument ROSINA Packet Description R2_ETS_10k (R2_Execute) Packet Function Mode 1 is the default ETS mode (pulser frequency: 10kH ). Generation Rules Use only after ETS is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_10k 2 octet Fixed field set to 6 Notes: Telecommand Packet Information Packet Name ZRNR2207 Instrument ROSINA Packet Description R2_ETS_SS (R2_Execute) Packet Function Set ETS to SS mode Generation Rules Use only after ETS is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_SS 2 octet Fixed field set to 7 Notes: First setup ETS general mode (e.g. mode 1 with command ZRNR2206). Telecommand Packet Information Packet Name ZRNR2208 Instrument ROSINA Packet Description R2_ETS_OS (R2_Execute) Packet Function Set ETS to OS mode Generation Rules Use only after ETS is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_OS 2 octet Fixed field set to 8 Notes: First setup ETS general mode (e.g. mode 1 with command ZRNR2206). Telecommand Packet Information Packet Name ZRNR2209 Instrument ROSINA Packet Description R2_ETS_CAL (R2_Execute) Packet Function Set ETS to calibration mode Generation Rules Use only after ETS is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_CAL 2 octet Fixed field set to 9 Notes: First setup ETS general mode (e.g. mode 1 with command ZRNR2206). Telecommand Packet Information Packet Name ZRNR220E Instrument ROSINA Packet Description R2_HEAT_OS (R2_Execute) Packet Function Switch on orthogonal source heater to clean it. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_HEAT_OS 2 octet Fixed field set to 14 Notes: Telecommand Packet Information Packet Name ZRNR220F Instrument ROSINA Packet Description R2_HEAT_SS (R2_Execute) Packet Function Switch on storage source heater. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_HEAT_SS 2 octet Fixed field set to 15 Notes: Telecommand Packet Information Packet Name ZRNR2210 Instrument ROSINA Packet Description R2_HEAT_OFF (R2_Execute) Packet Function Switch off all heaters Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_HEAT_OFF 2 octet Fixed field set to 16 Notes: Telecommand Packet Information Packet Name ZRNR2211 Instrument ROSINA Packet Description R2_ETL_10k (R2_Execute) Packet Function Mode 1 is the default ETS Light mode (pulser frequency 10kHz). Generation Rules Use only after ETSL is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_10k 2 octet Fixed field set to 17 Notes: Telecommand Packet Information Packet Name ZRNR2212 Instrument ROSINA Packet Description R2_ETL_SS (R2_Execute) Packet Function Set ETS Light to SS mode Generation Rules Use only after ETSL is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_SS 2 octet Fixed field set to 18 Notes: First setup ETSL general mode (e.g. mode 1 with command ZRNR2211). Telecommand Packet Information Packet Name ZRNR2213 Instrument ROSINA Packet Description R2_ETL_OS (R2_Execute) Packet Function Set ETS Light to OS mode Generation Rules Use only after ETSL is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_OS 2 octet Fixed field set to 19 Notes: First setup ETSL general mode (e.g. mode 1 with command ZRNR2211). Telecommand Packet Information Packet Name ZRNR221B Instrument ROSINA Packet Description R2_ETL_CAL (R2_Execute) Packet Function Set ETS Light to calibration mode Generation Rules Use only after ETSL is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_CAL 2 octet Fixed field set to 27 Notes: First setup ETSL general mode (e.g. mode 1 with command ZRNR2211). Telecommand Packet Information Packet Name ZRNR221C Instrument ROSINA Packet Description R2_HMP_ON (R2_Execute) Packet Function Switch on hard mirror pulser Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_HMP_ON 2 octet Fixed field set to 28 Notes: Telecommand Packet Information Packet Name ZRNR221F Instrument ROSINA Packet Description R2_ETL_DTS10 (R2_Execute) Packet Function Set ETL to DTS 10ns mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_DTS10 2 octet Fixed field set to 31 Notes: Telecommand Packet Information Packet Name ZRNR2220 Instrument ROSINA Packet Description R2_ETL_DTS30 (R2_Execute) Packet Function Set ETL to DTS 30ns mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETL_DTS30 2 octet Fixed field set to 32 Notes: Telecommand Packet Information Packet Name ZRNR2221 Instrument ROSINA Packet Description R2_ETS_DTS10 (R2_Execute) Packet Function Set ETS to DTS 10ns mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_DTS10 2 octet Fixed field set to 33 Notes: Telecommand Packet Information Packet Name ZRNR2222 Instrument ROSINA Packet Description R2_ETS_DTS30 (R2_Execute) Packet Function Set ETS to DTS 30ns mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_DTS30 2 octet Fixed field set to 34 Notes: Telecommand Packet Information Packet Name ZRNR2223 Instrument ROSINA Packet Description R2_ETS_BOTH (R2_Execute) Packet Function Set ETS/ETL to master slave mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A R2_ETS_BOTH 2 octet Fixed field set to 35 Notes: 3.2.5 ZRNR2003 (R2_Function) Telecommand Packet Information Packet Name ZRNR2303 Instrument ROSINA Packet Description OR_PULSER On (R2_Function) Packet Function Set all needed voltages and enable pulser Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_PULSER 2 octet Fixed field set to 3 PRNGR201 Pulser on settings 4 octet Contains 5 detailed parameters PRNDR201 R-Spare1 16 bits Not modifiable, set to 0 PRNDR269 R-Spare 4 bits Not modifiable, set to 0 PRNDR202 Switch ON 4 bits Not modifiable, set to 1 PRNDR203 Pulser table 6 bits Calcurve CRNVR202 0 = Test 1 = SRSS (single refl, storage src) 2 = TRSS (triple refl, storage src) 3 = SROS (single refl, orthogonal src) 4 = TROS (triple refl, orthogonal src) PRNDR266 Spare 1 bit Not modifiable, set to 0 PRNDR204 Select pulser on 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2383 Instrument ROSINA Packet Description OR_PULSER Off (R2_Function) Packet Function Disable pulser and reset all voltages Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_PULSER 2 octet Fixed field set to 3 PRNGR202 Pulser off settings 4 octet Contains 5 detailed parameters PRNDR205 R-Spare1 16 bits Not modifiable, set to 0 PRNDR26A R-Spare 4 bits Not modifiable, set to 0 PRNDR206 Switch OFF 4 bits Not modifiable, set to 14 PRNDR207 Spare 7 bits Not modifiable, set to 0 PRNDR208 Select pulser off 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2304 Instrument ROSINA Packet Description OR_ETSPOW On (R2_Function) Packet Function Switch power of ETS/ETS light on Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_ETSPOW 2 octet Fixed field set to 4 PRNGR210 ETS Power on settings 4 octet Contains 3 detailed parameters PRNDR240 R-Spare1 24 bits Not modifiable, set to 0 PRNDR241 Switch ETS ON 4 bits Not modifiable, set to 1 PRNDR242 ETS ON Unit Selection 4 bits Calcurve CRNVR203 0 = ETS 1 = ETS light PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2384 Instrument ROSINA Packet Description OR_ETSPOW Off (R2_Function) Packet Function Switch power of ETS/ETS light off Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_ETSPOW 2 octet Fixed field set to 4 PRNGR211 ETS Power off settings 4 octet Contains 3 detailed parameters PRNDR243 R-Spare1 24 bits Not modifiable, set to 0 PRNDR244 Switch ETS OFF 4 bits Not modifiable, set to 14 PRNDR245 ETS OFF Unit Selection 4 bits Calcurve CRNVR203 0 = ETS 1 = ETS light PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2305 Instrument ROSINA Packet Description OR_FILA On (R2_Function) Packet Function Setup all needed voltages and enable filament Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_FILA 2 octet Fixed field set to 5 PRNGR204 RTOF Filament ON Settings 4 octet Contains 5 detailed pa ameters: PRNDR210 R-Spare1 24 bits Not modifiable, set to 0 PRNDR211 R-Filament ON 4 bits Not modifiable, set to 1 PRNDR212 R-Spare4 2 bits Not modifiable, set to 0 PRNDR213 Filament ON OS/SS 1 bit Calcurve CRNVR206 0 = SS 1 = OS PRNDR214 Filament on selection 1 bit Calcurve CRNVR207 0 = Filament 1 1 = Filament 2 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR205 Set emission current 4 octet Set current in uA (floating po nt) PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2385 Instrument ROSINA Packet Description OR_FILA Off (R2_Function) Packet Function Disable filament and reset all needed voltages Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_FILA 2 octet Fixed field set to 5 PRNGR212 RTOF Filament Off Settings 4 octet Contains 5 detailed pa ameters: PRNDR246 R-Spare1 24 bits Not modifiable, set to 0 PRNDR247 R-Filament OFF 4 bits Not modifiable, set to 14 PRNDR248 R-Spare4 2 bits Not modifiable, set to 0 PRNDR249 Filament OFF OS/SS 1 bit Calcurve CRNVR206 0 = SS 1 = OS PRNDR250 Spare 1 bit Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR23C5 Instrument ROSINA Packet Description OR_FILA Standby (R2_Function) Packet Function Put filament and all needed voltages to standby Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_FILA 2 octet Fixed field set to 5 PRNGR216 RTOF Filament Off Settings 4 octet Contains 5 detailed pa ameters: PRNDR26B R-Spare1 24 bits Not modifiable, set to 0 PRNDR26C R-Filament standby 4 bits Not modifiable, set to 0 PRNDR26D R-Spare4 2 bits Not modifiable, set to 0 PRNDR26E Filament OFF OS/SS 1 bit Calcurve CRNVR206 0 = SS 1 = OS PRNDR26F Spare 1 bit Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR217 Standby emission current 4 octet Not modifiable, set to 9 (FP) PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR2306 Instrument ROSINA Packet Description OR_READETS (R2_Function) Packet Function Start ETS acquisition, readout and send science data t S/C Generation Rules Use only after ETS is switched on Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Read ETS 2 octet Fixed field set to 6 PRNGR203 Set NOE (0 = off): 20, Set compr. (0 = off): 12 4 octet Set number of extractions PRNGR213 ETS readout settings 4 octet Contains 6 detailed parameters PRNDR260 ETS acquisition time 24 bits Time between start acquisition and readout in ms PRNDR261 Spare 2 bits Not modifiable, set to 0 PRNDR267 RAM test 1 bit Calcurve CRNVG004 0 = Disable 1 = Enable PRNDR268 High/low ram test 1 bit Decimal value PRNDR262 ETS HIRM mode 1 bit Calcurve CRNVG004 0 = Disable 1 = Enable PRNDR270 Repeat readout 1 bit Calcurve CRNVG004 0 = Disable 1 = Enable PRNDR264 Select ETL 1 bit Calcurve CRNVG004 0 = Disable 1 = Enable PRNDR265 Select ETS 1 bit Calcurve CRNVG004 0 = Disable 1 = Enable PRNGR214 ETS Upper address in ns 4 octet Upper readout address (FP) PRNGR215 ETS Lower address in ns 4 octet Lower readout address (FP) Notes: Telecommand Packet Information Packet Name ZRNR2307 Instrument ROSINA Packet Description OR_ABORT (R2_Function) Packet Function Abort all RTOF functions. Generation Rules Emergency use only. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Abort functions 2 octet Fixed field set to 7 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRNR23F8 Instrument ROSINA Packet Description OR_COVER (R2_Function) Packet Function Operate RTOF cover motor after pyro fired Generation Rules DO NOT USE ON GROUND! Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A RTOF Cover Ops 2 octet Fixed field set to 8 PRNGR252 RTOF PAD-16 bits 2 octet Not modifiable, set to 0. PRNGR250 RTOF Cover motor power 2 octet Contains 7 detailed parameters PRNDR263 R-Spare4 2 bits Not modifiable, set to 0 PRNDR251 Motor velocity 2 bits Calcurve CRNVR220 0 = 5 Hz 1 = 10 Hz 2 = 20 Hz 3 = 40 Hz PRNDR252 Spare 4 bits Not modifiable, set to 0 PRNDR253 Motor hall sensor 2 bits Calcurve CRNVR221 1 = Off 2 = On PRNDR254 Direct open/close 2 bits Calcurve CRNVR222 0 = Move 1 = Close cover to end switch 2 = Open cover to end switch PRNDR255 R-Spare4 2 bits Not modifiable, set to 0 PRNDR256 Motor high torque 2 bits Calcurve CRNVR221 1 = Off 2 = On PRNGR253 RTOF PAD-16 bits 2 octet Not modifiable, set to 0. PRNGR251 RTOF cover action 2 octet Contains 2 detailed parameters PRNDR257 Cover command 1 octet Calcurve CRNVR223 0 = Move cover to absolute Pos. (default) 1 = Move cover relative steps 6 = Cover reset (open cover) 24 = Check last move complete PRNDR258 Cover position/steps 1 octet Limit Set LRNR0258 Allowed range: 0 (open) - 20 (close), TBC PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0. Notes: SHALL NOT BE USED ON GROUND. For security, an enable command (ZRNR1002) has to be sent before the command w ll be accepted by DPU. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRNR230A Instrument ROSINA Packet Description OR_HVUP (R2_Function) Packet Function Step up all RTOF high voltages except MCP. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_HVUP 2 octet Fixed field set to 10 PRNGR206 RTOF HV Up settings 4 octet Contains 5 detailed parameters PRNDR220 R-Spare1 24 bits Not modifiable, set to 0 PRNDR223 RTOF HV Up table 6 bits Calcurve CRNVR202 0 = Test 1 = SRSS (single refl, storage src) 2 = TRSS (triple refl, storage src) 3 = SROS (single refl, orthogonal src) 4 = TROS (triple refl, orthogonal src) PRNDR222 R-HV Up Include hard mirror pulser 1 bit Calcurve CRNVR 08 0 = Excluded 1 = Included PRNDR224 RTOF HV Up OS/SS 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR230B Instrument ROSINA Packet Description OR_HVDOWN (R2_Function) Packet Function Step down all RTOF high voltages to init values, except MCP. Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_HVDOWN 2 octet Fixed field set to 11 PRNGR207 RTOF HV Down settings 4 octet Contains 6 detailed parameters PRNDR225 R-Spare1 24 bits Not modifiable, set to 0 PRNDR226 Spare 5 bits Not modifiable, set to 0 PRNDR229 RTOF Common HV Off 1 bit Calcurve CRNVR212 0 = Keep On 1 = All Off PRNDR227 R-HV Down Include hard mirror pulser 1 bit Calcurve CRNVR 08 0 = Excluded 1 = Included PRNDR230 RTOF HV Down OS/SS 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR230C Instrument ROSINA Packet Description OR_MCP On (R2_Function) Packet Function Step up RTOF MCP high voltage Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_MCP 2 octet Fixed field set to 12 PRNGR208 RTOF MCP HV Up settings 4 octet Contains 4 detailed parameters PRNDR231 R-Spare1 24 bits Not modifiable, set to 0 PRNDR233 RTOF MCP HV Up table 6 bits Calcurve CRNVR202 0 = Test 1 = SRSS (single refl, storage src) 2 = TRSS (triple refl, storage src) 3 = SROS (single refl, orthogonal src) 4 = TROS (triple refl, orthogonal src) PRNDR232 Spare 1 bit Not modifiable, set to 0 PRNDR234 RTOF MCP HV Up OS/SS 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: Telecommand Packet Information Packet Name ZRNR238C Instrument ROSINA Packet Description OR_MCP Off (R2_Function) Packet Function Step down RTOF MCP high voltage Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OR_MCP 2 octet Fixed field set to 12 PRNGR209 MCP HV down settings 4 octet Contains 4 detailed parameters PRNDR235 R-Spare1 24 bits Not modifiable, set to 0 PRNDR236 Spare 4 bits Not modifiable, set to 0 PRNDR237 Spare 3 bits Not modifiable, set to 0 PRNDR238 RTOF MCP HV Down OS/SS 1 bit Calcurve CRNVR201 0 = SS 1 = OS PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: 3.2.6 ZRNR3004 (R3_Acquisition) Same functionality and parameters as ZRNR2003 (R2_Function). 3.2.7 ZRNR4001 (R4_Mode) Telecommand Packet Information Packet Name ZRNR4100 Instrument ROSINA Packet Description R4_Mode Packet Function Setup and operate single mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 50 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG401 Mode No. 2 octet Number of mode (see RTOF measurement m des docu) PRNGG402 Mass 2 octet Set single mass (0 = default, use mass from mo e entry) PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 PRNGR200 RTOF PAD-32 bits 4 octet Not modifiable, set to 0 Notes: 3.2.8 ZRNR4003 (R4_LoadLUT) Telecommand Packet Information Packet Name ZRNR4301 Instrument ROSINA Packet Description R4_LoadLUT 1 word Packet Function Load 1 word in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 52 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR402 Table No. 1 octet Calcurve CRNVR103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x40: RSRSS 0x41: RTRSS 0x42: RSROS 0x43: RTROS 0x44: R200SRSS 0x45: R200TRSS 0x46: R3MOT 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGR403 Parameter 4 octet Table parameter PRNGR252 RTOF PAD-16 bits 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR4302 Instrument ROSINA Packet Description R4_LoadLUT 2 words Packet Function Load 2 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 52 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR402 Table No. 1 octet Calcurve CRNVR103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x40: RSRSS 0x41: RTRSS 0x42: RSROS 0x43: RTROS 0x44: R200SRSS 0x45: R200TRSS 0x46: R3MOT 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 2 PRNGR403 Parameter 2 * 4 octet Table parameter PRNGR252 RTOF PAD-16 bits 2 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR4304 Instrument ROSINA Packet Description R4_LoadLUT 4 words Packet Function Load 4 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 52 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR402 Table No. 1 octet Calcurve CRNVR103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x40: RSRSS 0x41: RTRSS 0x42: RSROS 0x43: RTROS 0x44: R200SRSS 0x45: R200TRSS 0x46: R3MOT 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 4 PRNGR403 Parameter 4 * 4 octet Table parameter PRNGR252 RTOF PAD-16 bits 4 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR4308 Instrument ROSINA Packet Description R4_LoadLUT 8 words Packet Function Load 8 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 52 Structure ID Packet length 64 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR402 Table No. 1 octet Calcurve CRNVR103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x40: RSRSS 0x41: RTRSS 0x42: RSROS 0x43: RTROS 0x44: R200SRSS 0x45: R200TRSS 0x46: R3MOT 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 8 PRNGR403 Parameter 8 * 4 octet Table parameter PRNGR252 RTOF PAD-16 bits 8 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR4310 Instrument ROSINA Packet Description R4_LoadLUT 16 words Packet Function Load 16 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 52 Structure ID Packet length 112 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGR402 Table No. 1 octet Calcurve CRNVR103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x40: RSRSS 0x41: RTRSS 0x42: RSROS 0x43: RTROS 0x44: R200SRSS 0x45: R200TRSS 0x46: R3MOT 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGR403 Parameter 16 * 4 octet Table parameter PRNGR252 RTOF PAD-16 bits 16 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. 3.2.9 ZRNR4004 (R4_SetConv) Telecommand Packet Information Packet Name ZRNR4400 Instrument ROSINA Packet Description R4_SetConv Packet Function Set entry of RTOF command conversion table [stConvTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 53 Structure ID Packet length 68 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG480 Table No. 2 octet pointer to table (default = 0, dummy = 0xFFFF) PRNGG416 Parameter No. 2 octet pointer to parameter entry PRNGR405 Function/Shift 2 octet Contains 3 detailed parameters: PRNDR401 Type 2 bits Type of calculation (default = 0) PRNDR402 Function 8 bits Calc. function Calcurve CRNVR104: 0 = Default 64 = XF_ACTIVE 128 = XF_DOUBLE PRNDR403 Shift 6 bits Shift command value (none = 0, left = 1..31, right = 32..63) PRNGG418 Mask 2 octet AND mask PRNGG419 Default 4 octet OR mask PRNGG41A Parameter Value 1 4 octet multiplier (floating point) PRNGG41B Parameter Value 2 4 octet offset (floating point) PRNGG41C Monitoring 2 octet monitoring function no. (default = 0) PRNGG41D Wait 2 octet wait time for monitoring in ms PRNGG41E Parameter Value 3 4 octet step width (floating point, de . = 0) PRNGG48B Sleep 2 octet Sleep time for steps in ms PRNGG48C Spare 2 octet Entry of switch command table (default = 0) PRNGG41F Parameter Value 4 4 octet Absolute min. limit (floating oint, default = 0) PRNGG481 Parameter Value 5 4 octet Absolute max. limit (floating oint, default = 0) PRNGG482 HK Cmd 1 4 octet sensor cmd for hk read (default = 0) PRNGG483 HK Cmd 2 4 octet sensor cmd for hk read PRNGG484 HK Cmd 3 4 octet sensor cmd for hk read PRNGG485 HK Cmd 4 4 octet sensor cmd for hk read Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. 3.2.10 ZRNR4006 (R4_LoadMode) Telecommand Packet Information Packet Name ZRNR4600 Instrument ROSINA Packet Description R4_LoadMode Packet Function Load entry of RTOF mode table [stModeMainTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 55 Structure ID Packet length 80 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG421 Mode No. 2 octet Mode entry in table (0xFFFF = dummy) PRNGG422 Func/Task 2 octet Contains 2 detailed parameters: PRNDG406 Function 1 octet Configuration (SS/OS/both/off/gas/ion/ ai/alt/ sin/tri/bla) PRNDG407 Task 1 octet Function (com/back/opt/cal) PRNGG423 Parameter Value 1 4 octet Ambient U1 (floating point) PRNGG424 Parameter Value 2 4 octet Ambient U2 (floating p int) PRNGG425 Parameter Value 3 4 octet Blank t1 (floating point) PRNGG426 Parameter Value 4 4 octet Blank t2 (floating point) PRNGG427 Emi/Res 2 octet Contains 2 detailed parameters: PRNDG408 Emission 1 octet Emission (off/sub/low/med/hi/heat) PRNDG409 Resolution 1 octet Electron energy (low/hi/var) PRNGG486 Filament 2 octet Filament selection PRNGG428 Electr. Energy 1 4 octet Var. energy U1 (floating point PRNGG429 Electr. Energy 2 4 octet Var. energy U2 (floating point PRNGG42A Zoom 4 octet Filament heater time (floating point) PRNGG487 Position 2 octet Start/stop cover positions (0 = no move) PRNGG42B Detector 6 octet Contains 5 detailed parameters: PRNDG40C Detector 1 octet Detector range selection (Freq/NOE/MLM) PRNDG40E Det. Threshold 1 octet Detector threshold (ETS/ETSL) PRNDG40D Det. Integration 2 octet Detector integration time or N E PRNDG40F Det. Configuration 1 octet Detector configuration (ETS/ET L) PRNDG410 Det. Extraction delay 1 octet Detector extraction delay in u PRNGG42C Mass Value 1 2 octet Not used, set to 0 PRNGG42D Mass Value 2 2 octet Start mass or mass table entry PRNGG42E Mass Value 3 2 octet Not used, set to 0 PRNGG42F Mass Value 4 2 octet Stop mass PRNGG430 Mass Value 5 2 octet Not used, set to 0 PRNGG431 Mass Value 6 2 octet Reference mass PRNGG432 Mass Value 7 2 octet Not used, set to 0 PRNGG433 Mass Value 8 2 octet Not used, set to 0 PRNGG434 Mass Value 9 2 octet Not used, set to 0 PRNGG435 Mass Value 10 2 octet Not used, set to 0 PRNGR406 Comp/Spare 4 octet Contains 2 detailed parameters: PRNDR404 Compression 2 octet Data compression parameter PRNDR405 Spare 2 octet Not used, set to 0 Notes: For security, an enable command (ZRNR1002) has to be sent before the command will be accepted by DPU. 3.2.11 ZRNR5001 (R5_Sequence) Telecommand Packet Information Packet Name ZRNR5001 Instrument ROSINA Packet Description R5_Sequence Packet Function Execute RTOF mode sequence Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 70 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG501 Sequence no. 2 octet Entry of RTOF sequence table to execut (0xFFFF = dummy) PRNGG503 Parameter Value 1 4 octet Parameter transferred to funct ons called in sequence table PRNGG504 Parameter Value 2 4 octet Parameter transferred to funct ons called in sequence table PRNGG505 Parameter Value 3 4 octet Parameter transferred to funct ons called in sequence table (FP) PRNGG506 Parameter Value 4 4 octet Parameter transferred to funct ons called in sequence table (FP) Notes: 3.2.12 ZRNR5002 (R5_LoadSeq) Telecommand Packet Information Packet Name ZRNR5201 Instrument ROSINA Packet Description R5_LoadSeq 1 word Packet Function Load 1 word to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 20 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 1 PRNGG508 Parameter Value 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR5209 Instrument ROSINA Packet Description R5_LoadSeq 1 entry Packet Function Load 1 entry to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 52 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 9 PRNGG508 Parameter Value 9 * 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR5212 Instrument ROSINA Packet Description R5_LoadSeq 2 entries Packet Function Load 2 entries to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 88 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 18 PRNGG508 Parameter Value 18 * 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR521B Instrument ROSINA Packet Description R5_LoadSeq 3 entries Packet Function Load 3 entries to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 124 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 27 PRNGG508 Parameter Value 27 * 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR5224 Instrument ROSINA Packet Description R5_LoadSeq 4 entries Packet Function Load 4 entries to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 160 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 36 PRNGG508 Parameter Value 36 * 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNR522D Instrument ROSINA Packet Description R5_LoadSeq 5 entries Packet Function Load 5 entries to RTOF mode sequence table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 200 Service Subtype 71 Structure ID Packet length 196 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of sequence table (default = 0, dummy = 0xFF) PRNGG521 Start position 2 octet Position in sequence table N/A Count 1 octet Fixed value set to 45 PRNGG508 Parameter Value 45 * 4 octet Table parameter/command Notes: For security, an enable command (ZRNR1002) has to be sent before the c mmand will be accepted by DPU. 3.3 COPS Type No. Name RSDB Serv Sub- serv Param Count Enable Description C1 C1_Direct ZRNC1001 204 1 1 X Direct COPS Command C2 C_Enable ZRNC1002 204 2 2 Enable Critical Command C10 C2_SetValue ZRNC2001 204 10 4 X Set & erify Value C11 C2_Execute ZRNC2002 204 11 1 Execut single Command C12 C2_Function ZRNC2003 204 12 5 Call F nction C50 C4_Mode ZRNC4001 204 50 8 Set & Operate ingle Mode C52 C4_LoadLUT ZRNC4003 204 52 5..79 X Load L ok Up Table C53 C4_SetConv ZRNC4004 204 53 16 X Set Co version Parameter C55 C4_LoadMode ZRNC4006 204 55 26 X Load M de Settings 3.3.1 ZRNC1001 (C1_Direct) Telecommand Packet Information Packet Name ZRNC1001 Instrument ROSINA Packet Description C1_Direct Packet Function Any three byte low-level command can be sent directly o the COPS (see RD[3] and sensor documentation) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 01 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG101 Command 4 octet Contains 2 detailed parameters: PRNDG101 Spare 1 octet Not modifiable, set to 0 PRNDG102 Sensor Command 3 octet COPS low-level command code Notes: For security, an enable command (ZRNC1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. 3.3.2 ZRNC1002 (C_Enable) Telecommand Packet Information Packet Name ZRNC1002 Instrument ROSINA Packet Description C_Enable Packet Function Enable critical command (enable column marked in table 3.3) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG102 Subservice 2 octet Contains 2 detailed parameters: PRNDG103 Spare 1 octet Not modifiable, set to 0 PRNDG104 Subservice of critical cmd 1 octet e.g. 1 for ZRNC1001 PRNGG103 Opcode of critical cmd 2 octet First two bytes of parameters e.g. spare 0 and first byte of sensor cmd for ZRNC1001) Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRNC1201 Instrument ROSINA Packet Description C_Enable SetValue Packet Function Enable COPS SetValue command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Subservice of cmd 2 octet Fixed field set to 10 PRNGC101 Set Voltage No. 2 octet Calcurve CRNVC101: NG_GRID = 1 NG_CURLO = 2 NG_CURHI = 3 NG_REGLO = 4 NG_REGHI = 5 RG_GRID = 6 RG_CURLO = 7 RG_CURHI = 8 RG_REGLO = 9 RG_REGHI = 10 NG_P12V = 11 NG_M12V = 12 RG_P12V = 13 RG_M12V = 14 Notes: One enable is valid until another enable command is sent. 3.3.3 ZRNC2001 (C2_SetValue) Telecommand Packet Information Packet Name ZRNC2001 Instrument ROSINA Packet Description C2_SetValue Packet Function Set any COPS internal voltage or parameter with the DP general voltage set function (taking into account required stepping and monit ring, e.g. COPS grid voltage) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG201 Parameter No. 2 octet Entry of set parameter in DPU cmd conv rsion table PRNGG202 Parameter Value 4 octet Set value in floating point PRNGG203 Wait time in ms 2 octet Optional wait time for HK monitoring a ter cmd was sent PRNGG204 Monitoring No. 2 octet Optional entry of related HK parameter in DPU monitoring table Notes: Optional parameters will overwrite existing DPU internal parameters. F r security, an enable command (ZRNC1002) has to be sent before the command wil be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNC2100 Instrument ROSINA Packet Description C2_SetValue Voltages Packet Function Set predefined COPS internal voltages with the DPU gen ral voltage set function (taking into account required stepping and monitoring Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 10 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC101 Set Voltage No. 2 octet Limit set LRNC0101 [1; 14] Calcurve CRNVC101: NG_GRID = 1 NG_CURLO = 2 NG_CURHI = 3 NG_REGLO = 4 NG_REGHI = 5 RG_GRID = 6 RG_CURLO = 7 RG_CURHI = 8 RG_REGLO = 9 RG_REGHI = 10 NG_P12V = 11 NG_M12V = 12 RG_P12V = 13 RG_M12V = 14 PRNGC102 Voltage Value 4 octet Set value in floating point N/A Wait time in ms 2 octet Fixed field set to 0 N/A Monitoring No. 2 octet Fixed field set to 0 Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. Internal use only. 3.3.4 ZRNC2002 (C2_Execute) Telecommand Packet Information Packet Name ZRNC2200 Instrument ROSINA Packet Description C2_Init (C2_Execute) Packet Function Set all COPS voltages to initial values Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A C2_Init 2 octet Fixed field set to 0 Notes: Telecommand Packet Information Packet Name ZRNC2201 Instrument ROSINA Packet Description C2_NGOFF (C2_Execute) Packet Function Switch off nude gauge Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A C2_NGOFF 2 octet Fixed field set to 1 Notes: Telecommand Packet Information Packet Name ZRNC2202 Instrument ROSINA Packet Description C2_RGOFF (C2_Execute) Packet Function Switch off ram gauge Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A C2_RGOFF 2 octet Fixed field set to 2 Notes: 3.3.5 ZRNC2003 (C2_Function) Telecommand Packet Information Packet Name ZRNC2302 Instrument ROSINA Packet Description OC_ABORT (C2_Function) Packet Function Abort all COPS functions. Generation Rules Emergency use only. Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Abort functions 2 octet Fixed field set to 2 PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Internal use only. To be acknowledged manually by ground operators. Telecommand Packet Information Packet Name ZRNC2303 Instrument ROSINA Packet Description OC_SWITCH (C2_Function) Packet Function Switch on and operate nude or ram gauge. Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OC_SWITCH 2 octet Fixed field set to 3 PRNGC201 COPS PAD-16 bits 2 octet Not modifiable, set to 0. PRNGC202 COPS Fil/MT settings 2 octet Contains 5 detailed parameters PRNDC201 Check Offset 4 bits Calcurve CRNVG008 1 = On 14 = Off PRNDC202 COPS Fil/MT Array 8 bits Select Filament or microtips a ray PRNDC203 COPS Ion Range 2 bits Calcurve CRNVC201 0 = Low 1 = Medium 3 = High PRNDC204 COPS Immission Range 1 bit Calcurve CRNVC202 0 = Low 1 = High PRNDC205 COPS Select Gauge 1 bit Calcurve CRNVC203 0 = Microtips 1 = Filament PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC204 COPS Max. Regulation 4 octet Maximum Regulation value to ap ly (FP). PRNGC203 COPS Current Limit 4 octet Current Limit for Fil/MT (FP). Notes: Telecommand Packet Information Packet Name ZRNC2304 Instrument ROSINA Packet Description OC_OFFSET (C2_Function) Packet Function Calculate offset of nude or ram gauge. Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OC_OFFSET 2 octet Fixed field set to 4 PRNGC201 COPS PAD-16 bits 2 octet Not modifiable, set to 0. PRNGC205 COPS Fil/MT select 2 octet Contains 2 detailed parameters PRNDC206 Spare 15 bits Not modifiable, set to 0 PRNDC207 COPS Select Gauge 1 bit Calcurve CRNVC203 0 = Microtips 1 = Filament PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRNC2306 Instrument ROSINA Packet Description OC_SINGOFF (C2_Function) Packet Function Switch off nude or ram gauge. Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OC_SINGOFF 2 octet Fixed field set to 6 PRNGC201 COPS PAD-16 bits 2 octet Not modifiable, set to 0. PRNGC205 COPS Fil/MT select 2 octet Contains 2 detailed parameters PRNDC206 Spare 15 bits Not modifiable, set to 0 PRNDC207 COPS Select Gauge 1 bit Calcurve CRNVC203 0 = Microtips 1 = Filament PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: Telecommand Packet Information Packet Name ZRNC2307 Instrument ROSINA Packet Description OC_AUTORANGE (C2_Function) Packet Function Switch on/off automatic range switching. Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OC_AUTORANGE 2 octet Fixed field set to 7 PRNGC201 COPS PAD-16 bits 2 octet Not modifiable, set to 0. PRNGC206 COPS automatic range 2 octet Contains 4 detailed parameters PRNDC208 Spare 1 octet Not modifiable, set to 0 PRNDC209 Automatic on/off 4 bits Calcurve CRNVG001: 1 = On 14 = Off PRNDC209 Spare 3 bits Not modifiable, set to 0 PRNDC207 COPS Select Gauge 1 bit Calcurve CRNVC203 0 = Microtips 1 = Filament PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: 3.3.6 ZRNC4001 (C4_Mode) Telecommand Packet Information Packet Name ZRNC4100 Instrument ROSINA Packet Description C4_Mode Packet Function Setup and operate single mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 50 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG401 Mode No. 2 octet Number of mode (see COPS measurement m des docu) PRNGG402 Mass 2 octet Set single mass (0 = default, use mass from mo e entry) PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. PRNGC200 COPS PAD-32 bits 4 octet Not modifiable, set to 0. Notes: 3.3.7 ZRNC4003 (C4_LoadLUT) Telecommand Packet Information Packet Name ZRNC4301 Instrument ROSINA Packet Description C4_LoadLUT 1 word Packet Function Load 1 word in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 52 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC402 Table No. 1 octet Calcurve CRNVC103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x11: STFIL2 (COPS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGC403 Parameter 4 octet Table parameter PRNGC201 COPS PAD-16 bits 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNC4302 Instrument ROSINA Packet Description C4_LoadLUT 2 words Packet Function Load 2 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 52 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC402 Table No. 1 octet Calcurve CRNVC103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x11: STFIL2 (COPS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 2 PRNGC403 Parameter 2 * 4 octet Table parameter PRNGC201 COPS PAD-16 bits 2 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNC4304 Instrument ROSINA Packet Description C4_LoadLUT 4 words Packet Function Load 4 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 52 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC402 Table No. 1 octet Calcurve CRNVC103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x11: STFIL2 (COPS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 4 PRNGC403 Parameter 4 * 4 octet Table parameter PRNGC201 COPS PAD-16 bits 4 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNC4308 Instrument ROSINA Packet Description C4_LoadLUT 8 words Packet Function Load 8 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 52 Structure ID Packet length 64 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC402 Table No. 1 octet Calcurve CRNVC103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x11: STFIL2 (COPS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 8 PRNGC403 Parameter 8 * 4 octet Table parameter PRNGC201 COPS PAD-16 bits 8 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNC4310 Instrument ROSINA Packet Description C4_LoadLUT 16 words Packet Function Load 16 words in look-up table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 52 Structure ID Packet length 112 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGC402 Table No. 1 octet Calcurve CRNVC103: 0 or 0xFF: Dummy 0x10: STFIL1 (D,C,R) 0x11: STFIL2 (COPS) 0x20: X3GEN (D,C,R) 0x21: XINIT (D,C,R) 0x22: XSET (D,C,R) 0x23: XISET (D,C,R) 0x50: TAB1 0x51: TAB2 0x52: TAB3 PRNGG489 Start Position 2 octet Set starting entry of table N/A Count 1 octet Fixed value set to 1 PRNGC403 Parameter 16 * 4 octet Table parameter PRNGC201 COPS PAD-16 bits 16 * 2 octet Not modifiable, set to 0. Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. 3.3.8 ZRNC4004 (C4_SetConv) Telecommand Packet Information Packet Name ZRNC4400 Instrument ROSINA Packet Description C4_SetConv Packet Function Set entry of DFMS command conversion table [stConvTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 53 Structure ID Packet length 68 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG480 Table No. 2 octet pointer to table (default = 0, dummy = 0xFFFF) PRNGG416 Parameter No. 2 octet pointer to parameter entry PRNGC405 Function/Shift 2 octet Contains 3 detailed parameters: PRNDC401 Type 2 bits Type of calculation (default = 0) PRNDC402 Function 8 bits Calc. function Calcurve CRNVC104: 0 = Default 2 = CF_INIT 64 = XF_ACTIVE 128 = XF_DOUBLE PRNDC403 Shift 6 bits Shift command value (none = 0, left = 1..31, right = 32..63) PRNGG418 Mask 2 octet AND mask PRNGG419 Default 4 octet OR mask PRNGG41A Parameter Value 1 4 octet multiplier (floating point) PRNGG41B Parameter Value 2 4 octet offset (floating point) PRNGG41C Monitoring 2 octet monitoring function no. (default = 0) PRNGG41D Wait 2 octet wait time for monitoring in ms PRNGG41E Parameter Value 3 4 octet step width (floating point, de . = 0) PRNGG48B Sleep 2 octet Sleep time for steps in ms PRNGG48C Spare 2 octet Entry of switch command table (default = 0) PRNGG41F Parameter Value 4 4 octet Absolute min. limit (floating oint, default = 0) PRNGG481 Parameter Value 5 4 octet Absolute max. limit (floating oint, default = 0) PRNGG482 HK Cmd 1 4 octet sensor cmd for hk read (default = 0) PRNGG483 HK Cmd 2 4 octet sensor cmd for hk read PRNGG484 HK Cmd 3 4 octet sensor cmd for hk read PRNGG485 HK Cmd 4 4 octet sensor cmd for hk read Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. 3.3.9 ZRNC4006 (C4_LoadMode) Telecommand Packet Information Packet Name ZRNC4600 Instrument ROSINA Packet Description C4_LoadMode Packet Function Load entry of COPS mode table [stModeMainTab] Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 204 Service Subtype 55 Structure ID Packet length 80 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG421 Mode No. 2 octet Mode entry in table (0xFFFF = dummy) PRNGG422 Func/Task 2 octet Contains 2 detailed parameters: PRNDG406 Function 1 octet Configuration (nud/ram/both) PRNDG407 Task 1 octet Function (non/amb/ofs) PRNGG423 Parameter Value 1 4 octet Not used, set to 0 PRNGG424 Parameter Value 2 4 octet Not used, set to 0 PRNGG425 Parameter Value 3 4 octet Not used, set to 0 PRNGG426 Parameter Value 4 4 octet Not used, set to 0 PRNGG427 Emi/Res 2 octet Contains 2 detailed parameters: PRNDG408 Emission 1 octet Not used, set to 0 PRNDG409 Resolution 1 octet Used algorithm PRNGG486 Filament 2 octet Filament selection PRNGG428 Electr. Energy 1 4 octet Not used, set to 0 PRNGG429 Electr. Energy 2 4 octet Not used, set to 0 PRNGG42A Zoom 4 octet Not used, set to 0 PRNGG487 Position 2 octet Not used, set to 0 PRNGG42B Detector 6 octet Contains 5 detailed parameters: PRNDG40C Detector 1 octet Not used, set to 0 PRNDG40E Not used 1 octet Not used, set to 0 PRNDG40D Det. Integration 2 octet Not used, set to 0 PRNDG40F Det. Configuration 1 octet Not used, set to 0 PRNDG410 Det. Gain 1 octet Not used, set to 0 PRNGG42C Mass Value 1 2 octet Not used, set to 0 PRNGG42D Mass Value 2 2 octet Not used, set to 0 PRNGG42E Mass Value 3 2 octet Not used, set to 0 PRNGG42F Mass Value 4 2 octet Not used, set to 0 PRNGG430 Mass Value 5 2 octet Not used, set to 0 PRNGG431 Mass Value 6 2 octet Not used, set to 0 PRNGG432 Mass Value 7 2 octet Not used, set to 0 PRNGG433 Mass Value 8 2 octet Not used, set to 0 PRNGG434 Mass Value 9 2 octet Not used, set to 0 PRNGG435 Mass Value 10 2 octet Not used, set to 0 PRNGG436 Compression 4 octet Not used, set to 0 Notes: For security, an enable command (ZRNC1002) has to be sent before the c mmand will be accepted by DPU. 4. DPU Commands 4.1 DPU Type No. Name RSDB Serv Sub- serv Param Count Enable Description P1 P1_Direct ZRNP1001 208 1 3 X Direct DPU Command P2 P_Enable ZRNP1002 208 2 2 Enable Critical Command P3 P1_Science ZRNP1003 208 3 3 Direct Science Readout P11 P2_Execute ZRNP2001 208 11 1 Execut single Command P12 P2_Function ZRNP2002 208 12 5 Call F nction P14 P2_LoadExeTab ZRNP2004 208 14 4..61 X Load E ecution Table P15 P2_LoadTable ZRNP2005 208 15 6..62 X Load T ble Entry P30 P3_LoadHK ZRNP3001 208 30 6 X Load H Table Entry P31 P3_LoadTM ZRNP3002 208 31 4 X Load S C TM Table Entry P32 P3_LoadFunction ZRNP3003 208 32 5..79 X Load F nction Code P33 P3_LoadSW ZRNP3004 208 33 4..78 X Load S ftware P34 P3_GetSetting ZRNP3005 208 34 4 Get Ta le Setting via Event P50 P4_Mode ZRNP4001 208 50 5 Set Operation ode 4.1.1 ZRNP1001 (P1_Direct) Telecommand Packet Information Packet Name ZRNP1101 Instrument ROSINA Packet Description Program Memory Test ON Packet Function Start program memory test (generates YRNG3002 event pa ket) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A PM Test ON 2 octet Fixed field set to 49409 (0xC101) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1181 Instrument ROSINA Packet Description Program Memory Test OFF Packet Function Stop program memory test Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A PM Test OFF 2 octet Fixed field set to 49422 (0xC10E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1102 Instrument ROSINA Packet Description Data Memory 1 Test ON Packet Function Start data memory 1 test (generates YRNG3003 event pac et) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A DM1 Test ON 2 octet Fixed field set to 49665 (0xC201) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1182 Instrument ROSINA Packet Description Data Memory 1 Test OFF Packet Function Stop data memory 1 test Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A DM1 Test OFF 2 octet Fixed field set to 49678 (0xC20E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1103 Instrument ROSINA Packet Description Data Memory 2 Test ON Packet Function Start data memory 2 test (generates YRNG3003 event pac et) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A DM2 Test ON 2 octet Fixed field set to 49681 (0xC211) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1183 Instrument ROSINA Packet Description Data Memory 2 Test OFF Packet Function Stop data memory 2 test Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A DM2 Test OFF 2 octet Fixed field set to 49694 (0xC21E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1104 Instrument ROSINA Packet Description Program EEPROM Memory Test ON Packet Function Start program EEPROM memory test (generates YRNG3004 e ent packet) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A EEPROM Mem Test ON 2 octet Fixed field set to 49153 (0xC001) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1184 Instrument ROSINA Packet Description Program EEPROM Memory Test OFF Packet Function Stop program EEPROM memory test Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A EEPROM Mem Test OFF 2 octet Fixed field set to 49166 (0xC00E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1105 Instrument ROSINA Packet Description Status EEPROM Memory Test ON Packet Function Start status EEPROM memory test (generates YRNG3004 ev nt packet) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Stat EEPROM Test ON 2 octet Fixed field set to 49169 (0xC011) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1185 Instrument ROSINA Packet Description Status EEPROM Memory Test OFF Packet Function Stop status EEPROM memory test Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Stat EEPROM Test OFF 2 octet Fixed field set to 49182 (0xC01E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1106 Instrument ROSINA Packet Description Program EEPROM ON Packet Function Switch power of program EEPROM on Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A EEPROM ON 2 octet Fixed field set to 32769 (0x8001) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1186 Instrument ROSINA Packet Description Program EEPROM OFF Packet Function Switch power of program EEPROM off Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A EEPROM OFF 2 octet Fixed field set to 32782 (0x800E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1107 Instrument ROSINA Packet Description Status EEPROM ON Packet Function Switch power of status EEPROM on Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A STAT EEPROM ON 2 octet Fixed field set to 32833 (0x8041) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1187 Instrument ROSINA Packet Description Status EEPROM OFF Packet Function Switch power of status EEPROM off Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A STAT EEPROM OFF 2 octet Fixed field set to 32846 (0x804E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1108 Instrument ROSINA Packet Description Data memory 2 ON Packet Function Switch power of data memory 2 on Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A SRAM2 ON 2 octet Fixed field set to 32865 (0x8061) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. Telecommand Packet Information Packet Name ZRNP1188 Instrument ROSINA Packet Description Data memory 2 OFF Packet Function Switch power of data memory 2 off Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 01 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A SRAM2 OFF 2 octet Fixed field set to 32878 (0x806E) Notes: For security, an enable command (ZRNP1002) has to be sent before the d rect command will be accepted by DPU. Internal use only. 4.1.2 ZRNP1002 (P_Enable) Telecommand Packet Information Packet Name ZRNP1002 Instrument ROSINA Packet Description P_Enable Packet Function Enable critical command (enable column marked in table 4.1) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP102 Subservice 2 octet Contains 2 detailed parameters: PRNDP104 Spare 1 octet 0 PRNDP105 Subservice of critical cmd 1 octet e.g. 1 for ZRNP1001 PRNGP110 Opcode of critical cmd 2 octet First two bytes of parameters e.g. PRNGP101 for ZRNP1001) Notes: One enable is valid until another enable command is sent. Telecommand Packet Information Packet Name ZRNP1201 Instrument ROSINA Packet Description Enable Program Memory Test ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A PM Test ON 2 octet Fixed field set to 49409 (0xC101) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1281 Instrument ROSINA Packet Description Enable Program Memory Test OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A PM Test OFF 2 octet Fixed field set to 49422 (0xC10E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1202 Instrument ROSINA Packet Description Enable Data Memory 1 Test ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A DM1 Test ON 2 octet Fixed field set to 49665 (0xC201) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1282 Instrument ROSINA Packet Description Enable Data Memory 1 Test OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A DM1 Test OFF 2 octet Fixed field set to 49678 (0xC20E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1203 Instrument ROSINA Packet Description Enable Data Memory 2 Test ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A DM2 Test ON 2 octet Fixed field set to 49681 (0xC211) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1283 Instrument ROSINA Packet Description Enable Data Memory 2 Test OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A DM2 Test OFF 2 octet Fixed field set to 49694 (0xC21E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1204 Instrument ROSINA Packet Description Enable Program EEPROM Memory Test ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A EEPROM Mem Test ON 2 octet Fixed field set to 49153 (0xC001) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1284 Instrument ROSINA Packet Description Enable Program EEPROM Memory Test OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A EEPROM Mem Test OFF 2 octet Fixed field set to 49166 (0xC00E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1205 Instrument ROSINA Packet Description Enable Status EEPROM Memory Test ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A Stat EEPROM Test ON 2 octet Fixed field set to 49169 (0xC011) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1285 Instrument ROSINA Packet Description Enable Status EEPROM Memory Test OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A Stat EEPROM Test OFF 2 octet Fixed field set to 49182 (0xC01E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1206 Instrument ROSINA Packet Description Enable Program EEPROM ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A EEPROM ON 2 octet Fixed field set to 32769 (0x8001) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1286 Instrument ROSINA Packet Description Enable Program EEPROM OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A EEPROM OFF 2 octet Fixed field set to 32782 (0x800E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1207 Instrument ROSINA Packet Description Enable Status EEPROM ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A STAT EEPROM ON 2 octet Fixed field set to 32833 (0x8041) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1287 Instrument ROSINA Packet Description Enable Status EEPROM OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A STAT EEPROM OFF 2 octet Fixed field set to 32846 (0x804E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1208 Instrument ROSINA Packet Description Enable Data memory 2 ON Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A SRAM2 ON 2 octet Fixed field set to 32865 (0x8061) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1288 Instrument ROSINA Packet Description Enable Data memory 2 OFF Packet Function Enable direct command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 1 2 octet Fixed field set to 1 N/A SRAM2 OFF 2 octet Fixed field set to 32878 (0x806E) Notes: Internal use only. Telecommand Packet Information Packet Name ZRNP1209 Instrument ROSINA Packet Description Enable GCU regulation Packet Function Enable P2_Function command Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 02 Structure ID Packet length 16 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Enable subservice 12 2 octet Fixed field set to 12 N/A OP_GCUREG 2 octet Fixed field set to 1 Notes: 4.1.3 ZRNP1003 (P1_Science) Telecommand Packet Information Packet Name ZRNP1301 Instrument ROSINA Packet Description Simulate Error Event Packet Function Forces the sending of a dummy error event to S/C Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 03 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Generate Error Event 2 octet Fixed field set to 33792 (0x8400) PRNGX101 Event Parameters 4 octet First four bytes of event data PRNGX102 Simulated Event ID 4 octet Event ID to send Notes: Internal use only. 4.1.4 ZRNP2001 (P2_Execute) Telecommand Packet Information Packet Name ZRNP2100 Instrument ROSINA Packet Description OP_Normal (P2_Execute) Packet Function Set sensor power interface to normal mode (I/F A & Pwr A / I/F B & Pwr B) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OP_Normal 2 octet Fixed field set to 0 Notes: Telecommand Packet Information Packet Name ZRNP2101 Instrument ROSINA Packet Description OP_Cross (P2_Execute) Packet Function Set sensor power interface to cross coupling mode (I/F A & Pwr B / I/F B & Pwr A) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 11 Structure ID Packet length 14 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OP_Cross 2 octet Fixed field set to 1 Notes: 4.1.5 ZRNP2002 (P2_Function) Telecommand Packet Information Packet Name ZRNP2201 Instrument ROSINA Packet Description OP_GCUREG DFMS (P2_Function) Packet Function Setup DFMS gas calibration unit regulation Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de DFMS. Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OP_GCUREG 2 octet Fixed field set to 1 N/A Unit DFMS 4 octet Fixed field set to 1 PRNGX201 Select DFMS GCU 4 octet Calcurve CRNVP201 1 = GCU 1 2 = GCU 2 N/A Monitoring table entry 4 octet Fixed field set to 1 PRNGX202 DFMS GCU out pressure limit 4 octet Regulation pressure li it in HK raw value Notes: For security, an enable command (ZRNP1209) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2202 Instrument ROSINA Packet Description OP_GCUREG RTOF (P2_Function) Packet Function Setup RTOF gas calibration unit regulation Generation Rules Controlled high vacuum (< 6 x 10-7 mbar) has to be ins de RTOF. Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 12 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A OP_GCUREG 2 octet Fixed field set to 1 N/A Unit RTOF 4 octet Fixed field set to 2 PRNGX203 Select RTOF GCU 4 octet Calcurve CRNVP201 1 = GCU 1 2 = GCU 2 N/A Monitoring table entry 4 octet Fixed field set to 1 PRNGX204 RTOF GCU out pressure limit 4 octet Regulation pressure li it in HK raw value Notes: For security, an enable command (ZRNP1209) has to be sent before the c mmand will be accepted by DPU. 4.1.6 ZRNP2004 (P2_LoadExeTab) Telecommand Packet Information Packet Name ZRNP2004 Instrument ROSINA Packet Description P2_LoadExeTab Packet Function Load sensor command execution tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 20..248 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGP221 Table No. 2 octet Extra function bits and pointer to command table entry PRNGP222 Count 1 octet Count of parameter PRNGP20A PRNGP20A Command table value 4 octet Entry for command table Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2401 Instrument ROSINA Packet Description Set table address (P2_LoadExeTab) Packet Function Set address in sensor command execution tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 20 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Function bits (Set table address, Add after pos 58, Add after pos 116, Spare) 8 bits (1 bit, 1 bit, 1 bit, 5 bit) Fixed field set to 128 PRNGX205 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 1 PRNGP20A Address of cmd table 4 octet Set address pointer Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2402 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 2 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 24 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 2 PRNGP20A Command table value 2 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2403 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 3 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 3 PRNGP20A Command table value 3 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2405 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 5 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 36 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 5 PRNGP20A Command table value 5 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP240A Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 10 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 56 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 10 PRNGP20A Command table value 10 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP240F Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 15 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 76 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 15 PRNGP20A Command table value 15 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2414 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 20 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 96 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 20 PRNGP20A Command table value 20 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2419 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 25 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 116 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 25 PRNGP20A Command table value 25 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP241E Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 30 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 136 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 30 PRNGP20A Command table value 30 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2428 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 40 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 176 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 40 PRNGP20A Command table value 40 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2432 Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 50 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 216 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 50 PRNGP20A Command table value 50 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP243A Instrument ROSINA Packet Description Load table (P2_LoadExeTab) Packet Function Load sensor command execution tables, length = 58 Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 14 Structure ID Packet length 248 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP220 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX206 Table No. 2 octet Contains 5 detailed parameters: PRNDX250 Set table address 1 bit Not modifiable set to 0 PRNDX202 Add after pos 58 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX203 Add after pos 116 1 bit Calcurve CRNVG002: 0 = OFF 1 = ON PRNDX251 Spare 5 bit Not modifiable set to 0 PRNDX201 Table No. 1 octet Pointer to command table entry N/A Count 1 octet Fixed field set to 58 PRNGP20A Command table value 58 * 4 octet Entry for command tabl Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.7 ZRNP2005 (P2_LoadTable) Telecommand Packet Information Packet Name ZRNP2005 Instrument ROSINA Packet Description P2_LoadTable Packet Function Load DPU tables for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 24..248 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNDP201 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNDP202 Type 1 octet Select type of table (255 = dummy) PRNGP20C Table No. 2 octet Select table number PRNGP20D Entry No. 2 octet Pointer to table entry PRNGP20E Count 2 octet Count of parameter PRNGP20F PRNGP20F Table value 4 octet Entry for table Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2501 Instrument ROSINA Packet Description Load monitoring table (P2_LoadTable) Packet Function Load DPU table for monitoring functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 52 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Type 1 octet Fixed field set to 16 N/A Table No. 2 octet Fixed field set to 0 PRNGP20D Entry No. 2 octet Pointer to table entry N/A Count 2 octet Fixed field set to 8 PRNGX207 Monitoring parameter 1 2 octet Contains 3 detailed parameters PRNDX204 Monitoring type 2 bit Default = 0 PRNDX205 Monitoring function 1 octet Default = 0, for not cmdble va ues: Wait count (2s steps) for error PRNDX206 Shift of HK value 6 bit Default = 18 (for 14bit HK val es) PRNGX208 And mask of HK value 2 octet Default = 0x3FFF PRNGX209 Multiplier of HK value 4 octet Floating point PRNGX20A Offset of HK value 4 octet Floating point Calc: Value = (Raw value & Mask) * Multiplier + Offset PRNGX20B Monitoring state 2 octet Default = 0, for not cmdble va ues: Wait count (2s steps) for error PRNGX20C Monitoring function 2 octet Calcurve CRNVP202: 0 = No 1 = GCU 2 = Cover 3 = CheckHK 4 = Cover Power 5 = Spare PRNGX20D Limit value 4 octet Floating point, Value = Set Value +- Limit PRNGX20E Offset for limit 4 octet Floating point, Active only, if value > Offset PRNGX20F Set value 4 octet Floating point, default = 0, Set only for not cmdble values PRNGX210 Entry of Set value table 2 octet Pointer to entry in se value conversion table PRNGX211 Entry of command table 2 octet Default = 0, Entry in cmd table which will be executed if monitor error Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2502 Instrument ROSINA Packet Description Load mode table (P2_LoadTable) Packet Function Load DPU mode table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Type 1 octet Fixed field set to 32 N/A Table No. 2 octet Fixed field set to 0 PRNGP20D Entry No. 2 octet Pointer to table entry N/A Count 2 octet Fixed field set to 13 PRNGX212 Mode command 4 octet P4_Mode mode no. cmd parameter PRNGX213 Mode parameter 1 4 octet Contains 3 detailed parameters PRNDX207 Repetition count 4 bit Repetition count for S/C Std/E t HK packets PRNDX208 Ext packet position 4 bit Position of S/C Ext HK packet in repetition cycle PRNDX209 Sleep time in s 3 octet Sleep time between HK packets PRNGX214 Mode status 2 octet Value of sensor mode PRNGX215 Mode check 2 octet Bits to check for mode transition PRNGX216 Command 1 2 octet Entry in sensor command/function table to execute for mode change PRNGX217 Command 2 2 octet Entry in sensor command/function table to execute for mode change PRNGX224 Cmd 1 Parameter 1 4 octet Parameter for command 1 PRNGX225 Cmd 1 Parameter 2 4 octet Parameter for command 1 PRNGX226 Cmd 1 Parameter 3 4 octet Parameter for command 1 (FP) PRNGX227 Cmd 1 Parameter 4 4 octet Parameter for command 1 (FP) PRNGX228 Cmd 2 Parameter 1 4 octet Parameter for command 2 PRNGX229 Cmd 2 Parameter 2 4 octet Parameter for command 2 PRNGX22A Cmd 2 Parameter 3 4 octet Parameter for command 2 (FP) PRNGX22B Cmd 2 Parameter 4 4 octet Parameter for command 2 (FP) PRNGX218 Parameter check 4 octet Bits of P4_Mode parameter 1 to check b fore mode change Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2503 Instrument ROSINA Packet Description Load switch command table (P2_LoadTable) Packet Function Load DPU switch command tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Type 1 octet Fixed field set to 48 N/A Table No. 2 octet Fixed field set to 0 PRNGP20D Entry No. 2 octet Pointer to table entry N/A Count 2 octet Fixed field set to 5 PRNGX219 Switch Count 4 octet Default = 0 PRNGX21A Command for switch-on 4 octet Sensor cmd to switch on PRNGX21B Command for switch-off 4 octet Sensor cmd to switch off PRNGX21C Status table 4 octet Entry of sensor status table to flag s itch on/off PRNGX21D Status bit 4 octet Bit position in entry of sensor status table to flag switch on/off Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2504 Instrument ROSINA Packet Description Load function table (P2_LoadTable) Packet Function Load DPU function tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 40 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Type 1 octet Fixed field set to 64 N/A Table No. 2 octet Fixed field set to 0 PRNGP20D Entry No. 2 octet Pointer to table entry N/A Count 2 octet Fixed field set to 5 PRNGX21E Function No. 4 octet Function no. used to addess function c de PRNGX21F Function parameter 1 4 octet Parameter for function PRNGX220 Function parameter 2 4 octet Parameter for function PRNGX221 Function parameter 3 4 octet Parameter for function PRNGX222 Function parameter 4 4 octet Parameter for function Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP2505 Instrument ROSINA Packet Description Load function address table (P2_LoadTable) Packet Function Load DPU function address table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 15 Structure ID Packet length 24 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Type 1 octet Fixed field set to 65 N/A Table No. 2 octet Fixed field set to 0 PRNGP20D Entry No. 2 octet Pointer to table entry N/A Count 2 octet Fixed field set to 1 PRNGX223 Function Address 4 octet Function address for new funct on Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.8 ZRNP3001 (P3_LoadHK) Telecommand Packet Information Packet Name ZRNP3001 Instrument ROSINA Packet Description P3_LoadHK Packet Function Load DPU HK tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNDP301 Type 1 octet Select type of table (255 = dummy) PRNDP302 Table No. 1 octet Select table number PRNGP302 Entry No. 2 octet Pointer to table entry PRNGP303 Parameter Value 1 4 octet Table entry PRNGP304 Parameter Value 2 4 octet Table entry PRNGP305 Parameter Value 3 4 octet Table entry Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3101 Instrument ROSINA Packet Description Load HKSubTable.iAll (P3_LoadHK) Packet Function Load DPU complete HKSubTable entry Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Type 1 octet Fixed field set to 16 PRNGX301 Table No. 1 octet Calcurve CRNVP301: 0 = stStatus 16 = stHKDFMS 17 = stHKDFMSGCU 32 = stHKRTOF 33 = stHKRTOFETS 34 = stHKRTOFETL 35 = stHKRTOFGCU 48 = stHKCOPS PRNGP302 Entry No. 2 octet Pointer to table entry PRNGX302 Command Value 4 octet Sensor command to read HK PRNGX303 Monitoring Value 4 octet Entry in monitoring table PRNGX304 HK Value 4 octet Default = 0 Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3102 Instrument ROSINA Packet Description Load HKSubTable.aiCmd (P3_LoadHK) Packet Function Load DPU Command HKSubTable entry Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Type 1 octet Fixed field set to 17 PRNGX301 Table No. 1 octet Calcurve CRNVP301: 0 = stStatus 16 = stHKDFMS 17 = stHKDFMSGCU 32 = stHKRTOF 33 = stHKRTOFETS 34 = stHKRTOFETL 35 = stHKRTOFGCU 48 = stHKCOPS PRNGP302 Entry No. 2 octet Pointer to table entry PRNGX302 Command Value 4 octet Sensor command to read HK N/A Spare 4 octet Fixed field set to 0 N/A Spare 4 octet Fixed field set to 0 Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3103 Instrument ROSINA Packet Description Load HKSubTable.aiMonitor (P3_LoadHK) Packet Function Load DPU Monitoring HKSubTable entry Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Type 1 octet Fixed field set to 18 PRNGX301 Table No. 1 octet Calcurve CRNVP301: 0 = stStatus 16 = stHKDFMS 17 = stHKDFMSGCU 32 = stHKRTOF 33 = stHKRTOFETS 34 = stHKRTOFETL 35 = stHKRTOFGCU 48 = stHKCOPS PRNGP302 Entry No. 2 octet Pointer to table entry PRNGX303 Monitoring Value 4 octet Entry in monitoring table N/A Spare 4 octet Fixed field set to 0 N/A Spare 4 octet Fixed field set to 0 Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3104 Instrument ROSINA Packet Description Load HKSubTable.aiValue (P3_LoadHK) Packet Function Load DPU HK Value HKSubTable entry Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Type 1 octet Fixed field set to 19 PRNGX301 Table No. 1 octet Calcurve CRNVP301: 0 = stStatus 16 = stHKDFMS 17 = stHKDFMSGCU 32 = stHKRTOF 33 = stHKRTOFETS 34 = stHKRTOFETL 35 = stHKRTOFGCU 48 = stHKCOPS PRNGP302 Entry No. 2 octet Pointer to table entry PRNGX304 HK Value 4 octet HK return value (overwritten by DPU if HK collection enabled) N/A Spare 4 octet Fixed field set to 0 N/A Spare 4 octet Fixed field set to 0 Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3105 Instrument ROSINA Packet Description Load HKMainTable (P3_LoadHK) Packet Function Load DPU Main HK Table entry Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 30 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Type 1 octet Fixed field set to 32 PRNGX305 Time slot No. 1 octet Number of time slot in 2s HK cycle (0. 9 in steps of 200ms). Limit set LRNX0305: [0; 9] PRNGP302 Entry No. 2 octet Pointer to table entry (0..19) PRNGX306 Table Value 4 octet Entry in HK main table N/A Spare 4 octet Fixed field set to 17 N/A Spare 4 octet Fixed field set to 17 Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.9 ZRNP3002 (P3_LoadTM) Telecommand Packet Information Packet Name ZRNP3002 Instrument ROSINA Packet Description P3_LoadTM Packet Function Load DPU S/C telemetry tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 31 Structure ID Packet length 24 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP306 Table No. 2 octet Calcurve CRNVP302: 0 = dummy 16 = aiSCHKMainTab 32 = aiSCHKStdDFMS 33 = aiSCHKExtDFMS 48 = aiSCHKStdRTOF 49 = aiSCHKExtRTOF 64 = aiSCHKStdCOPS 65 = aiSCHKExtCOPS 80 = aiSCHKStdDPU 81 = aiSCHKExtDPU PRNGP307 Entry No. 2 octet Pointer to table entry PRNGP308 Parameter Value 1 4 octet Table entry PRNGP309 Parameter Value 2 4 octet Next table entry Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.10 ZRNP3003 (P3_LoadFunction) Telecommand Packet Information Packet Name ZRNP3003 Instrument ROSINA Packet Description P3_LoadFunction Packet Function Load program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 22..244 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGP321 Function No. 2 octet Offset and entry in function table (dummy = 0xFFFF PRNGP322 Count 1 octet Count of parameter PRNGP30C PRNGP30C Code value 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3302 Instrument ROSINA Packet Description Load 2 words (P3_LoadFunction) Packet Function Load 2 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 2 PRNGP30C Code value 2 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3303 Instrument ROSINA Packet Description Load 3 words (P3_LoadFunction) Packet Function Load 3 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 34 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 3 PRNGP30C Code value 3 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3305 Instrument ROSINA Packet Description Load 5 words (P3_LoadFunction) Packet Function Load 5 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 46 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 5 PRNGP30C Code value 5 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP330A Instrument ROSINA Packet Description Load 10 words (P3_LoadFunction) Packet Function Load 10 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 76 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 10 PRNGP30C Code value 10 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3314 Instrument ROSINA Packet Description Load 20 words (P3_LoadFunction) Packet Function Load 20 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 136 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 20 PRNGP30C Code value 20 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP331E Instrument ROSINA Packet Description Load 30 words (P3_LoadFunction) Packet Function Load 30 words of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 196 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 30 PRNGP30C Code value 30 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3326 Instrument ROSINA Packet Description Load 38 words (P3_LoadFunction) Packet Function Load 38 word of program code for basic functions Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 32 Structure ID Packet length 244 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP320 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNGX307 Offset 1 octet Offset to begin of function code in 38 word s eps PRNGX308 Function 1 octet Entry in function table as reference t pfuncPatchAddr to get address N/A Count 1 octet Fixed field set to 38 PRNGP30C Code value 38 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.11 ZRNP3004 (P3_LoadSW) Telecommand Packet Information Packet Name ZRNP3004 Instrument ROSINA Packet Description P3_LoadSW Packet Function Load program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 24..246 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code PRNGP30E Count 2 octet Count of parameter PRNGP30F PRNGP30F Code value 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3401 Instrument ROSINA Packet Description Load 1 word (P3_LoadSW) Packet Function Load 1 word of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 24 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 1 PRNGP30F Code value 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3402 Instrument ROSINA Packet Description Load 2 words (P3_LoadSW) Packet Function Load 2 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 2 PRNGP30F Code value 2 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3403 Instrument ROSINA Packet Description Load 3 words (P3_LoadSW) Packet Function Load 3 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 36 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 3 PRNGP30F Code value 3 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3405 Instrument ROSINA Packet Description Load 5 words (P3_LoadSW) Packet Function Load 5 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 48 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 5 PRNGP30F Code value 5 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP340A Instrument ROSINA Packet Description Load 10 words (P3_LoadSW) Packet Function Load 10 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 78 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 10 PRNGP30F Code value 10 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3414 Instrument ROSINA Packet Description Load 20 words (P3_LoadSW) Packet Function Load 20 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 138 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 20 PRNGP30F Code value 20 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNP3426 Instrument ROSINA Packet Description Load 2 words (P3_LoadSW) Packet Function Load 2 words of program code Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 33 Structure ID Packet length 246 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGP30D Code address 4 octet PM address of code N/A Count 2 octet Fixed field set to 38 PRNGP30F Code value 38 * 6 octet Value of program code Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 4.1.12 ZRNP3005 (P3_GetSetting) Telecommand Packet Information Packet Name ZRNP3005 Instrument ROSINA Packet Description P3_GetSetting Packet Function Get setting of DPU tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNDP317 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNDP318 Table type 1 octet Set type of table (dummy = 0) PRNGP311 Table No. 2 octet Set number of table PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3501 Instrument ROSINA Packet Description Get astXConv table (P3_GetSetting) Packet Function Get entry of DPU command conversion tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS N/A Table type 1 octet Fixed field set to 1 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3502 Instrument ROSINA Packet Description Get command table (P3_GetSetting) Packet Function Get entry of DPU command tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Table type 1 octet Fixed field set to 2 PRNGX309 Table No. 2 octet Number of table in apiXExec PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3503 Instrument ROSINA Packet Description Get apiXExec table (P3_GetSetting) Packet Function Get entry of DPU command list tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Table type 1 octet Fixed field set to 3 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3504 Instrument ROSINA Packet Description Get astXFunc table (P3_GetSetting) Packet Function Get entry of DPU function tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Table type 1 octet Fixed field set to 4 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3505 Instrument ROSINA Packet Description Get astXMon table (P3_GetSetting) Packet Function Get entry of DPU monitoring tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS N/A Table type 1 octet Fixed field set to 5 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3506 Instrument ROSINA Packet Description Get astXMode table (P3_GetSetting) Packet Function Get entry of DPU sensor mode tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS N/A Table type 1 octet Fixed field set to 6 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3507 Instrument ROSINA Packet Description Get sensor table (P3_GetSetting) Packet Function Get entry of sensor specific tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS N/A Table type 1 octet Fixed field set to 7 PRNGX30A Sensor table No. 2 octet Number of sensor table: 0x10: stFilament (D,R,C) 0x11: astCOPSRange_RG 0x12: stMCPLinTh (DFMS) 0x20: afX3_General (D,R,C) 0x21: afX_Init (D,R,C) 0x22: afX_Set (D,R,C) 0x23: aiX_ISet (D,R,C) 0x30: afD3_MCPGain 0x31: afD3_MCPGainCEM 0x32: aiD3_MotorSet 0x33: aiD3_ESACoarse 0x34: afD3_CEMScan 0x35: afD3_LEDAScan 0x36: afD3_FCScan 0x37: aiDFMS_MCP_GAS 0x38: aiDFMS_MCP_ION 0x40: afR3_SRSS 0x41: afR3_TRSS 0x42: afR3_SROS 0x43: afR3_TROS PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3508 Instrument ROSINA Packet Description Get stHKSubTab table (P3_GetSetting) Packet Function Get entry of DPU housekeeping tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 208 = DPU N/A Table type 1 octet Fixed field set to 8 PRNGX30B HK table No. 2 octet Calcurve CRNVP301: 0 = stStatus 1 = stHKDUMMY 16 = stHKDFMS 17 = stHKDFMSGCU 32 = stHKRTOF 33 = stHKRTOFETS 34 = stHKRTOFETL 35 = stHKRTOFGCU 48 = stHKCOPS PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP3509 Instrument ROSINA Packet Description Get aiHKMainTab table (P3_GetSetting) Packet Function Get entry of DPU HK main table Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 208 = DPU N/A Table type 1 octet Fixed field set to 9 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP350A Instrument ROSINA Packet Description Get aiSCHKXTab table (P3_GetSetting) Packet Function Get entry of DPU S/C housekeeping tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 208 = DPU N/A Table type 1 octet Fixed field set to 10 PRNGP306 Table No. 2 octet Calcurve CRNVP302: 0 = dummy 16 = aiSCHKMainTab 32 = aiSCHKStdDFMS 33 = aiSCHKExtDFMS 48 = aiSCHKStdRTOF 49 = aiSCHKExtRTOF 64 = aiSCHKStdCOPS 65 = aiSCHKExtCOPS 80 = aiSCHKStdDPU 81 = aiSCHKExtDPU PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP350B Instrument ROSINA Packet Description Get stOpMode table (P3_GetSetting) Packet Function Get entry of DPU operation mode tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 208 = DPU N/A Table type 1 octet Fixed field set to 11 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP350C Instrument ROSINA Packet Description Get pfuncPatchAddrX table (P3_GetSetting) Packet Function Get entry of function address tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU N/A Table type 1 octet Fixed field set to 12 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). Telecommand Packet Information Packet Name ZRNP350D Instrument ROSINA Packet Description Get stSwitchCmdTab table (P3_GetSetting) Packet Function Get entry of switch command tables Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 34 Structure ID Packet length 18 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX250 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS N/A Table type 1 octet Fixed field set to 13 N/A Table No. 2 octet Fixed field set to 1 PRNGP312 Table entry no. 2 octet Entry of table Notes: Produces event report YRNG3011 (EID 44008). 4.1.13 ZRNP4001 (P4_Mode) Telecommand Packet Information Packet Name ZRNP4001 Instrument ROSINA Packet Description P4_Mode Packet Function Set main operation mode Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 50 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGX400 Mode No. 2 octet Calcurve CRNVP401: MODE_D1 = 0x80d1 MODE_D2 = 0x80d2 MODE_D3 = 0x80d3 MODE_D4 = 0x80d4 MODE_D5 = 0x80d5 MODE_S1 = 0x80a1 MODE_S1T = 0x80b1 MODE_E1 = 0x80e1 MODE_G1 = 0x80f1 MODE_1L = 0x8101 MODE_1G = 0x8201 MODE_1I = 0x8301 MODE_1 = 0x8001 MODE_S2 = 0x80a2 MODE_S2T = 0x80b2 MODE_E2 = 0x80e2 MODE_G2 = 0x80f2 MODE_2 = 0x8002 MODE_3 = 0x8003 MODE_S4 = 0x80a4 MODE_E4 = 0x80e4 MODE_G4 = 0x80f4 MODE_4 = 0x8004 MODE_S5 = 0x80a5 MODE_E5 = 0x80e5 MODE_G5 = 0x80f5 MODE_5M = 0x8105 MODE_5F = 0x8205MODE_5 = 0x8005 PRNGX401 Mode change functions 4 octet Contains 16 detailed parameter PRNDX401 Test pressure condition 1 bit Calcurve CRNVG004 0 = DISABLE 1 = ENABLE (default) PRNDX402 Additional power on only (go to all on mode) 1 bit Calcurve CRNVG004: 0 = DISABLE (default) 1 = ENABLE PRNDX403 Monitoring active 1 1 bit Monitoring active if PRNDX403 = PRNDX404 (default) PRNDX404 Monitoring active 2 1 bit PRNDX405 Switch off units not needed 1 bit Calcurve CRNVG004: 0 = DISABLE (default) 1 = ENABLE PRNDX406 Spare 1 bit Default = 0 PRNDX407 Spare 1 bit Default = 0 PRNDX408 Spare 1 bit Default = 0 PRNDX409 Spare 1 bit Default = 0 PRNDX40A Spare 1 bit Default = 0 PRNDX40B Spare 1 bit Default = 0 PRNDX40C Spare 1 bit Default = 0 PRNDX450 Spare 16 bit Fixed field set to 0 PRNDX40D Emergency switch off all units 1 bit Calcurve CRNVG004: 0 = DISABLE (default) 1 = ENABLE PRNDX40E Close cover 2 bit Calcurve CRNVP402: 0 = DISABLE (default) 1 = DISABLE 2 = DISABLE 3 = ENABLE PRNDX40F Switch off all units 1 bit Calcurve CRNVG004: 0 = DISABLE (default) 1 = ENABLE PRNGX402 Parameter Value 2 4 octet Parameter 2 PRNGX403 Pressure value 4 octet Max pressure in 10-10 mbar to switch o HVs (0 = disable pressure check) PRNGX404 Parameter Value 4 4 octet Parameter 4 Notes: If all units are switched off, event YRNG300D (EID 44301) is sent Telecommand Packet Information Packet Name ZRNP4101 Instrument ROSINA Packet Description D2_Mode with all units off (P4_Mode) Packet Function Configure all units to standby mode, switch off and go to mode D2 (cover not moved) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 208 Service Subtype 50 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks N/A Mode No. 2 octet Fixed field set to 0x80D2 N/A Mode change functions 4 octet Fixed field set to 1 N/A Parameter Value 2 4 octet Fixed field set to 0 N/A Pressure value 4 octet Fixed field set to 0 N/A Parameter Value 4 4 octet Fixed field set to 0 Notes: If all units are switched off, event YRNG300D (EID 44301) is sent 5. Instrument Commands 5.1 All sensors Type No. Name RSDB Serv Sub- serv Param Count P_Enable Description I50 I4_Pressure ZRNG4001 192 50 5 Enable Pressure Check I70 I5_Sequence ZRNG5001 192 70 5 Sequen e DFMS & RTOF I71 I5_LoadSeq ZRNG5002 192 71 6..177 X Load S quence Table I72 I5_Compression ZRNG5003 192 72 5 Data C mpression I73 I5_Detect ZRNG5004 192 73 10 Automa ic Mass Detect 5.1.1 ZRNG4001 (I4_Pressure) Telecommand Packet Information Packet Name ZRNG4001 Instrument ROSINA Packet Description I4_Pressure Packet Function Set overall pressure limit Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 50 Structure ID Packet length 26 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG437 Mode No. 2 octet Calcurve CRNVP401: MODE_D1 = 0x80d1 MODE_D2 = 0x80d2 MODE_D3 = 0x80d3 MODE_D4 = 0x80d4 MODE_D5 = 0x80d5 MODE_S1 = 0x80a1 MODE_S1T = 0x80b1 MODE_E1 = 0x80e1 MODE_G1 = 0x80f1 MODE_1L = 0x8101 MODE_1G = 0x8201 MODE_1I = 0x8301 MODE_1 = 0x8001 MODE_S2 = 0x80a2 MODE_S2T = 0x80b2 MODE_E2 = 0x80e2 MODE_G2 = 0x80f2 MODE_2 = 0x8002 MODE_3 = 0x8003 MODE_S4 = 0x80a4 MODE_E4 = 0x80e4 MODE_G4 = 0x80f4 MODE_4 = 0x8004 MODE_S5 = 0x80a5 MODE_E5 = 0x80e5 MODE_G5 = 0x80f5 MODE_5M = 0x8105 MODE_5F = 0x8205 MODE_5 = 0x8005 PRNGG438 Soft Limit 4 octet Pressure limit for alert event in mbar (floating point) PRNGG439 Soft Limit function no. 2 octet Entry of DPU function table to execute if soft limit reached PRNGG43A Hard Limit 4 octet Pressure limit for switch off in mbar floating point) PRNGG43B Hard Limit function no. 2 octet Entry of DPU function table to execute if hard limit reached Notes: 5.1.2 ZRNG5001 (I5_Sequence) Telecommand Packet Information Packet Name ZRNG5001 Instrument ROSINA Packet Description I5_Sequence Packet Function Execute DPU instrument command sequence Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 70 Structure ID Packet length 30 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG501 Sequence no. 2 octet Entry of instrument sequence table to xecute (0xFFFF = dummy) PRNGG503 Parameter Value 1 4 octet Parameter transferred to funct ons called in sequence table PRNGG504 Parameter Value 2 4 octet Parameter transferred to funct ons called in sequence table PRNGG505 Parameter Value 3 4 octet Parameter transferred to funct ons called in sequence table (FP) PRNGG506 Parameter Value 4 4 octet Parameter transferred to funct ons called in sequence table (FP) Notes: 5.1.3 ZRNG5002 (I5_LoadSeq) Telecommand Packet Information Packet Name ZRNG5002 Instrument ROSINA Packet Description I5_LoadSeq Packet Function Load DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 20..248 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table (0xFF = dummy) PRNGG521 Start position 2 octet Position in entry of sequence table PRNGG522 Count 1 octet Number of entries to write PRNGG508 Parameter Value 4 octet Command to put in sequence table Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5202 Instrument ROSINA Packet Description Load 2 words (I5_LoadSeq) Packet Function Load 2 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 24 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 2 PRNGG508 Parameter Value 2 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5203 Instrument ROSINA Packet Description Load 3 words (I5_LoadSeq) Packet Function Load 3 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 28 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 3 PRNGG508 Parameter Value 3 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5205 Instrument ROSINA Packet Description Load 5 words (I5_LoadSeq) Packet Function Load 5 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 36 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 5 PRNGG508 Parameter Value 5 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5210 Instrument ROSINA Packet Description Load 10 words (I5_LoadSeq) Packet Function Load 10 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 56 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 10 PRNGG508 Parameter Value 10 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5220 Instrument ROSINA Packet Description Load 20 words (I5_LoadSeq) Packet Function Load 20 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 96 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 20 PRNGG508 Parameter Value 20 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5230 Instrument ROSINA Packet Description Load 30 words (I5_LoadSeq) Packet Function Load 30 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 136 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 30 PRNGG508 Parameter Value 30 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5240 Instrument ROSINA Packet Description Load 40 words (I5_LoadSeq) Packet Function Load 40 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 176 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 40 PRNGG508 Parameter Value 40 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5250 Instrument ROSINA Packet Description Load 50 words (I5_LoadSeq) Packet Function Load 50 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 216 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 50 PRNGG508 Parameter Value 50 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. Telecommand Packet Information Packet Name ZRNG5258 Instrument ROSINA Packet Description Load 58 words (I5_LoadSeq) Packet Function Load 58 word of DPU instrument command sequence Generation Rules Used only for S/W update Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 71 Structure ID Packet length 248 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG520 Sequence no. 1 octet Entry of instrument sequence table PRNGG521 Start position 2 octet Position in entry of sequence table N/A Count 1 octet Fixed value set to 2 PRNGG508 Parameter Value 58 * 4 octet Command to put in sequence tab Notes: For security, an enable command (ZRNP1002) has to be sent before the c mmand will be accepted by DPU. 5.1.4 ZRNG5003 (I5_Compression) Telecommand Packet Information Packet Name ZRNG5003 Instrument ROSINA Packet Description I5_Compression Packet Function Set compression mode (overwrite default table entries) Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 72 Structure ID Packet length 22 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG50F Mode No. 2 octet Number of compression mode (Default = 0 = No compression, 0x0001..0x00FF = Integration, 0xFF01..0xFFFF = compression) PRNGG510 Parameter Value 1 2 octet Contains 2 detailed parameters PRNDG510 Unit 1 octet Calcurve CRNVG007: 196 = DFMS 200 = RTOF 204 = COPS 208 = DPU PRNDG511 Spare 1 octet Compression parameter 1 PRNGG511 Parameter Value 2 2 octet Compression parameter 2 PRNGG512 Parameter Value 3 2 octet Compression parameter 3 PRNGG513 Parameter Value 4 2 octet Compression parameter 4 Notes: 5.1.5 ZRNG5004 (I5_Detect) Telecommand Packet Information Packet Name ZRNG5004 Instrument ROSINA Packet Description I5_Detect Packet Function Automatically detect masses. Generation Rules Header Information Process ID 80 Packet Category 12 Service Type 192 Service Subtype 73 Structure ID Packet length 48 Data Field Information Parameter Name Parameter Description Field Structure Remarks PRNGG514 Mode No. 2 octet Calcurve CRNVP401: MODE_D1 = 0x80d1 MODE_D2 = 0x80d2 MODE_D3 = 0x80d3 MODE_D4 = 0x80d4 MODE_D5 = 0x80d5 MODE_S1 = 0x80a1 MODE_S1T = 0x80b1 MODE_E1 = 0x80e1 MODE_G1 = 0x80f1 MODE_1L = 0x8101 MODE_1G = 0x8201 MODE_1I = 0x8301 MODE_1 = 0x8001 MODE_S2 = 0x80a2 MODE_S2T = 0x80b2 MODE_E2 = 0x80e2 MODE_G2 = 0x80f2 MODE_2 = 0x8002 MODE_3 = 0x8003 MODE_S4 = 0x80a4 MODE_E4 = 0x80e4 MODE_G4 = 0x80f4 MODE_4 = 0x8004 MODE_S5 = 0x80a5 MODE_E5 = 0x80e5 MODE_G5 = 0x80f5 MODE_5M = 0x8105 MODE_5F = 0x8205 MODE_5 = 0x8005 PRNGG515 Sequence No. 2 octet Entry of instrument sequence table PRNGG517 Parameter Value 1 4 octet Parameter 1 PRNGG518 Parameter Value 2 4 octet Parameter 2 PRNGG519 Parameter Value 3 4 octet Parameter 3 PRNGG51A Parameter Value 4 4 octet Parameter 4 PRNGG51B Parameter Value 5 4 octet Parameter 5 PRNGG51C Parameter Value 6 4 octet Parameter 6 PRNGG51D Parameter Value 7 4 octet Parameter 7 PRNGG51E Parameter Value 8 4 octet Parameter 8 Notes: