OBJECT            = COLUMN
  NAME            = "TABLE_TIME_UTC"
  DATA_TYPE       = TIME
  START_BYTE      = 1
  BYTES           = 23
  UNIT            = "N/A"
  DESCRIPTION     = "UTC Time in PDS standard format
                     YYYY-MM-DDThh:mm:ss.sss"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "TABLE_TIME_OOBT"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 26
  BYTES           = 17
  MISSING_CONSTANT = "  9/9999999.99999"
  DESCRIPTION     = "Orbiter On Board Time
                     OOBT is represented as:
                     Reset number (integer starting at 1) / seconds.
                     Reset number 1 starts at 2003-01-01T00:00:00 UTC
                     The time resolution is 1/65536 s"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "TABLE_TYPE"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 46
  BYTES           = 3
  DESCRIPTION     = "Possible values:
                     TBL for Configuration table containing the operational
                     parameters which can be modified in the onboard software
                     CTL for Control sequence, used to get a detailed status
                     of the experiment (also containing the configuration table"
 
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "TABLE_NUMBER"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 52
  BYTES           = 12
  FORMAT          = "N/A"
  DESCRIPTION     = "Table number, given in the form x/y , where:
                     x is the current number of the table in the PDS dataset
                     y is the maximum number of tables found in the PDS dataset"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "TABLE_BYTES_HEX"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 67
  BYTES           = 17
  DESCRIPTION     = "Configuration table, containing all the operational
                     parameters, given as 6 bytes in Hexadecimal format
                     (one link-packet between PIU and RPC-MIP), separated by
                     a blank character.
                     The description is given below :
 
                     byte 0
                                bits 4,3   : Interference frequency #1
                     byte 1
                                bits 4,3   : Interference frequency #2
                     byte 2
                                bits 4,3   : Interference frequency #3
                     byte 3
                                bits 7,6   : Transmission_level
                                bits 5,4   : Transmitter_odd_sweeps
                                bits 3,2   : Transmitter_even_sweeps
                                bits 1,0   : Extremum_threshold
                     byte 4
                                bits 7,6,5 : Sweep_mode_bandwidth
                                bits 4,3,2 : Survey_mode_bandwidth
                                bit 1      : Ampl_pas
                                bit 0      : Autoloop
                     byte 5
                                bit  7     : Watchdog
                                bits 6,5,4 : Science_sequence_number
                                bit  3     : LDL_type
                                bit  2     : Mode
                                bits 1,0   : TM_rate"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "INTERF_FREQ1"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 86
  BYTES           = 4
  UNIT            = KILOHERTZ
  FORMAT          = "I4"
  DESCRIPTION     = "Interference frequency number 1
                     i.e. frequency to be ignored during the on-boar
                     extremum detection the active modes"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "INTERF_FREQ2"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 91
  BYTES           = 4
  UNIT            = KILOHERTZ
  FORMAT          = "I4"
  DESCRIPTION     = "Interference frequency number 2
                     i.e. frequency to be ignored during the on-boar
                     extremum detection the active modes"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "INTERF_FREQ3"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 96
  BYTES           = 4
  UNIT            = KILOHERTZ
  FORMAT          = "I4"
  DESCRIPTION     = "Interference frequency number 3
                     i.e. frequency to be ignored during the on-boar
                     extremum detection the active modes"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "TRANSMISSION_LEVEL"
  DATA_TYPE       = ASCII_REAL
  START_BYTE      = 101
  BYTES           = 5
  UNIT            = "N/A"
  FORMAT          = "F5.3"
  DESCRIPTION     = "Level of the transmitted signal
                     Possible values: {1.000, 0.500, 0.250, 0.125}
                     1.000 for full level,
                        (156 mV RMS in MIP mode, 30 V RMS in LDL mode)
                     0.500 for nominal level,
                        (78 mV RMS in MIP mode, 15 V RMS in LDL mode)
                     0.250 for low level,
                        (39 mV RMS in MIP mode, 7.5 V RMS in LDL mode)
                     0.125 for minimum level,
                        (19.5 mV RMS in MIP mode, 3.75 V RMS in LDL mode) "
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "TRANSMISSION_ODD"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 108
  BYTES           = 29
  UNIT            = "N/A"
  DESCRIPTION     = "Transmitter configuration for odd sweeps (1, 3, ...)
                     Possible values:
                     mono with E1
                     mono with E2
                     stereo with E1-E2 phased
                     stereo with E1-E2 anti-phased"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "TRANSMISSION_EVEN"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 140
  BYTES           = 29
  UNIT            = "N/A"
  DESCRIPTION     = "Transmitter configuration for even sweeps (2, 4, ...)
                     Possible values:
                     mono with E1
                     mono with E2
                     stereo with E1-E2 phased
                     stereo with E1-E2 anti-phased"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "MODE"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 172
  BYTES           = 9
  UNIT            = "N/A"
  DESCRIPTION     = "SDL/LDL transmitter configuration:
                     Possible values: {MIP alone, LDL mode}
                     MIP alone for SDL
                     LDL mode for LDL"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "AUTOLOOP"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 184
  BYTES           = 16
  UNIT            = "N/A"
  DESCRIPTION     = "Autoloop : an auto-loop can be set between emission
                     and reception
                     Possible values:
                     MIP with sensor
                     MIP auto-loop ON"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "AMPL_PAS"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 202
  BYTES           = 1
  UNIT            = DECIBEL
  FORMAT          = "I1"
  DESCRIPTION     = "Coding level for the power spectrum in Passive mode
                     0 dB = 0.6 microV*Hz**-0.5
                     Possible values: {2, 4}
                     2, for 16 values from 0 to 30 dB
                     4, for 16 values from 0 to 60 dB"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "EXT_THRESHOLD"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 204
  BYTES           = 1
  UNIT            = DECIBEL
  FORMAT          = "I1"
  DESCRIPTION     = "Amplitude threshold for the extremum detection
                     0 dB = 0.6 microV*Hz**-0.5
                     Possible values:
                     1
                     2
                     4
                     8"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "SURVEY_BAND"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 206
  BYTES           = 1
  UNIT            = "N/A"
  FORMAT          = "I1"
  DESCRIPTION     = "Frequency table used in Survey modes
                     Possible values: 0 to 7
                     Frequency tables are described below, with details on
                     bandwidth         resolution        number of steps
 
                     Table #0 (nominal) from 28 kHz to 3472 kHz, decomposed as:
                       28 - 224  kHz       7 kHz           29
                      238 - 448  kHz      14 kHz           16
                      476 - 896  kHz      28 kHz           16
                      952 - 1792 kHz      56 kHz           16
                     1904 - 3472 kHz     112 kHz           15
                    
                     Table #1 from 28 kHz to 665 kHz
                       28 - 665 kHz        7 kHz           92
 
                     Table #2 from 259 kHz to 896 kHz
                      259 - 896  kHz       7 kHz           92
                     
                     Table #3 from 518 kHz to 1792 kHz
                      518 - 1792 kHz      14 kHz           92
                     
                     Table #4 from 924 kHz to 3472 kHz
                      924 - 3472 kHz      28 kHz           92
                     
                     Table #5 from 357 kHz to 987 kHz, decomposed as:
                       28 - 343  kHz       7 kHz           46
                      357 - 987  kHz      14 kHz           46
                     
                     Table #6 from 28 kHz to 1582 kHz, decomposed as:
                       28 - 224  kHz       7 kHz           29
                      238 - 630  kHz      14 kHz           29
                      658 - 1582 kHz      28 kHz           34
                      
                     Table #7 from 266 kHz to 2184 kHz, decomposed as:
                      266 - 896  kHz      14 kHz           46
                      924 - 2184 kHz      28 kHz           46"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "SWEEP_BAND"
  DATA_TYPE       = ASCII_INTEGER
  START_BYTE      = 208
  BYTES           = 1
  UNIT            = "N/A"
  FORMAT          = "I1"
  DESCRIPTION     = "Frequency table used in Sweep modes
                     Possible values: 0 to 7
                     Frequency tables are described below, with details on
                     bandwidth         resolution        number of steps
 
                     Table #0 (nominal) from 28 kHz to 3472 kHz, decomposed as:
                       28 - 224  kHz       7 kHz           29
                      238 - 448  kHz      14 kHz           16
                      476 - 896  kHz      28 kHz           16
                      952 - 1792 kHz      56 kHz           16
                     1904 - 3472 kHz     112 kHz           15
                    
                     Table #1 from 28 kHz to 665 kHz
                       28 - 665 kHz        7 kHz           92
 
                     Table #2 from 259 kHz to 896 kHz
                      259 - 896  kHz       7 kHz           92
                     
                     Table #3 from 518 kHz to 1792 kHz
                      518 - 1792 kHz      14 kHz           92
                     
                     Table #4 from 924 kHz to 3472 kHz
                      924 - 3472 kHz      28 kHz           92
                     
                     Table #5 from 357 kHz to 987 kHz, decomposed as:
                       28 - 343  kHz       7 kHz           46
                      357 - 987  kHz      14 kHz           46
                     
                     Table #6 from 28 kHz to 1582 kHz, decomposed as:
                       28 - 224  kHz       7 kHz           29
                      238 - 630  kHz      14 kHz           29
                      658 - 1582 kHz      28 kHz           34
                      
                     Table #7 from 266 kHz to 2184 kHz, decomposed as:
                      266 - 896  kHz      14 kHz           46
                      924 - 2184 kHz      28 kHz           46"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "WATCHDOG"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 211
  BYTES           = 12
  UNIT            = "N/A"
  DESCRIPTION     = "MIP watchdog status
                     Possible values:
                     watchdog on
                     watchdog off"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
  NAME            = "TM_RATE"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 226
  BYTES           = 12
  UNIT            = "N/A"
  DESCRIPTION     = "Telemetry rate
                     Possible values:
                     minimum rate
                     normal rate
                     burst rate"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "SEQUENCE_NR"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 241
  BYTES           = 27
  UNIT            = "N/A"
  DESCRIPTION     = "MIP sequence number
                     Possible values:
                     nominal sequence
                     complementary sequence nr 1
                     complementary sequence nr 2
                     complementary sequence nr 3
                     complementary sequence nr 4
                     complementary sequence nr 5
                     complementary sequence nr 6
                     complementary sequence nr 7"
END_OBJECT        = COLUMN
 
OBJECT            = COLUMN
  NAME            = "LDL_TYPE"
  DATA_TYPE       = CHARACTER
  START_BYTE      = 271
  BYTES           = 10
  UNIT            = "N/A"
  DESCRIPTION     = "LDL type
                     Possible values:
                     normal LDL
                     mixed LDL"
END_OBJECT        = COLUMN