OBJECT                  = COLUMN
   NAME                 = "SPECTRUM_UT"
   DATA_TYPE            = TIME
   START_BYTE           = 1
   BYTES                = 23
   UNIT                 = "N/A"
   DESCRIPTION          = "Spectrum UT
                           Format : YYYY-MM-DDThh:mm:ss.sss"
 END_OBJECT             = COLUMN

OBJECT                  = COLUMN
   NAME                 = "SPECTRUM_OBT"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 26
   BYTES                = 17
   UNIT                 = "N/A"
   MISSING_CONSTANT     = "  9/9999999.99999"
   DESCRIPTION          = "Spectrum On board Time :
                           OOBT IS REPRESENTED AS :
                           Reset number (integer starting at 1) / seconds.
                           Reset number 1 starts at 2003-01-01T00:00:00 UTC
                           The time resolution is 1/65536 s
                           MISSING_CONSTANT in case of wrong OOBT value"
 END_OBJECT             = COLUMN

OBJECT                 = COLUMN
   NAME                 = "MODE"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 46
   BYTES                = 7
   UNIT                 = "N/A"
   DESCRIPTION          = "Possible value is :
                           PASSIVE"
 END_OBJECT             = COLUMN

OBJECT                 = COLUMN
   NAME                 = "SUB_MODE"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 56
   BYTES                = 6
   UNIT                 = "N/A"
   DESCRIPTION          = " Possible values are :
                           FULL
                           WINDOW
                           POWER"
 END_OBJECT             = COLUMN

OBJECT                 = COLUMN
   NAME                 = "SPECTRUM_TYPE"
   DATA_TYPE            = CHARACTER
   START_BYTE           = 65
   BYTES                = 5
   UNIT                 = "N/A"
   MISSING_CONSTANT     = "XXXXX"
   DESCRIPTION          = "Possible values are : POWER or MISSING_CONSTANT
                           in case of power sub-mode"
 END_OBJECT             = COLUMN

OBJECT                 = COLUMN
   NAME                 = "FREQUENCY"
   DATA_TYPE            = ASCII_INTEGER
   START_BYTE           = 72
   BYTES                = 7
   UNIT                 = "KILOHERTZ"
   FORMAT               = "I7"
   DESCRIPTION          = "Frequency
                           For power sub-mode, the central frequency of
                           frequency bandwidth is given:
                           LF part [7-448]: 220
                           HF part [476-3584]: 1554"
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
   NAME                 = "POWER"
   DATA_TYPE            = ASCII_REAL
   START_BYTE           = 80
   BYTES                = 7
   UNIT                 = "DECIBEL"
   FORMAT               = "F7.2"
   DESCRIPTION          = "Power
                           0 dB = 0.6 microV*Hz**-0.5"
 END_OBJECT             = COLUMN