OBJECT            = COLUMN
 COLUMN_NUMBER    = 1
 NAME             = "PLASMA_DENSITY_UTC_TIME"
 DATA_TYPE        = TIME
 START_BYTE       = 1
 BYTES            = 23
 FORMAT           = "A23"
 DESCRIPTION      = "UTC time of the plasma density, in PDS standard
                     format YYYY-MM-DDThh:mm:ss.sss"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 2
 NAME             = "DELTA_TIME"
 DATA_TYPE        = ASCII_REAL
 START_BYTE       = 25
 BYTES            = 6
 UNIT             = "S"
 FORMAT           = "F6.4"
 DESCRIPTION      = "Estimated uncertainty of the plasma density UTC Time"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 3
 NAME             = "PLASMA_DENSITY"
 DATA_TYPE        = ASCII_REAL
 START_BYTE       = 32
 BYTES            = 9
 UNIT             = "CM^-3"
 FORMAT           = "F9.2"
 DESCRIPTION      = "Plasma density"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 4
 NAME             = "UNCERTAINTY_PLASMA_DENSITY"
 DATA_TYPE        = ASCII_REAL
 START_BYTE       = 42
 BYTES            = 9
 UNIT             = "CM^-3"
 FORMAT           = "F9.2"
 DESCRIPTION      = "Estimated uncertainty of the plasma density"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 5
 NAME             = "QUALITY"
 DATA_TYPE        = ASCII_REAL
 START_BYTE       = 52
 BYTES            = 4
 UNIT             = "N/A"
 FORMAT           = "F4.2"
 DESCRIPTION      = "Quality of the cross-calibration process.
                     Value ranges from 0 (worst quality) to 1 (best quality).
                     See RPCMIP User Guide and RPCMIP/RPCLAP Cross-Calibration
                     Report for more details"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 6
 NAME             = "LAP_MODE"
 DATA_TYPE        = CHARACTER
 START_BYTE       = 58
 BYTES            = 2
 UNIT             = "N/A"
 FORMAT           = "A2"
 DESCRIPTION      = "RPC-LAP measurement used as input for the cross-calibration.
                     Possible values are:
                       I1 for ion current collected by RPC-LAP probe 1
                       I2 for ion current collected by RPC-LAP probe 2
                       V1 for floating potential collected by RPC-LAP probe 1
                       V2 for floating potential collected by RPC-LAP probe 2"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 7
 NAME             = "LAP_MACRO"
 DATA_TYPE        = ASCII_INTEGER
 START_BYTE       = 62
 BYTES            = 3
 UNIT             = "N/A"
 FORMAT           = "I3"
 DESCRIPTION      = "RPC-LAP macro_ID (three digits):
                     each RPC-LAP macro_ID is typical of particular settings
                     of the two RPC-LAP probes.
                     See RPC-LAP documentation and RPCMIP/RPCLAP Cross-Calibration
                     Report for more details"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 8
 NAME             = "MIP_MODE"
 DATA_TYPE        = CHARACTER
 START_BYTE       = 67
 BYTES            = 14
 UNIT             = "N/A"
 FORMAT           = "A14"
 DESCRIPTION      = "RPC-MIP instrument mode at the time of acquisition
                     Possible values are: SDL_E1, SDL_E2, SDL_Phased,
                     SDL_AntiPhased, LDL_Full, LDL_Window)"
END_OBJECT        = COLUMN

OBJECT            = COLUMN
 COLUMN_NUMBER    = 9
 NAME             = "MIP_TMRATE"
 DATA_TYPE        = CHARACTER
 START_BYTE       = 84
 BYTES            = 11
 UNIT             = "N/A"
 FORMAT           = "A11"
 DESCRIPTION      = "RPC-MIP instrument telemetry rate (Normal rate, Burst rate)"
END_OBJECT        = COLUMN