This is a logfile for the ros measurement on 171 Times are given in the format YYYYMMDDhhmm GRV Measurement time: 201606191840 - 201606200300 Checking files of DOY 171 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_D1_184026_0000 MG11_ROSE_2016_171_OP_D1_184026_0001 MG11_ROSE_2016_171_OP_D1_184026_0002 MG11_ROSE_2016_171_OP_D1_184026_0003 MG11_ROSE_2016_171_OP_D1_184026_0004 MG11_ROSE_2016_171_OP_D1_184026_0005 MG11_ROSE_2016_171_OP_D1_184026_0006 MG11_ROSE_2016_171_OP_D1_184026_0007 MG11_ROSE_2016_171_OP_D1_184026_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_G1_174703_0000 MG11_ROSE_2016_171_OP_G1_174703_0001 MG11_ROSE_2016_171_OP_G1_174703_0002 MG11_ROSE_2016_171_OP_G1_174703_0003 MG11_ROSE_2016_171_OP_G1_174703_0004 MG11_ROSE_2016_171_OP_G1_174703_0005 MG11_ROSE_2016_171_OP_G1_174703_0006 MG11_ROSE_2016_171_OP_G1_174703_0007 MG11_ROSE_2016_171_OP_G1_174703_0008 MG11_ROSE_2016_171_OP_G1_174703_0009 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191747 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_CL_D1_170704_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_D2_184026_0000 MG11_ROSE_2016_171_OP_D2_184026_0001 MG11_ROSE_2016_171_OP_D2_184026_0002 MG11_ROSE_2016_171_OP_D2_184026_0003 MG11_ROSE_2016_171_OP_D2_184026_0004 MG11_ROSE_2016_171_OP_D2_184026_0005 MG11_ROSE_2016_171_OP_D2_184026_0006 MG11_ROSE_2016_171_OP_D2_184026_0007 MG11_ROSE_2016_171_OP_D2_184026_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_G2_174703_0000 MG11_ROSE_2016_171_OP_G2_174703_0001 MG11_ROSE_2016_171_OP_G2_174703_0002 MG11_ROSE_2016_171_OP_G2_174703_0003 MG11_ROSE_2016_171_OP_G2_174703_0004 MG11_ROSE_2016_171_OP_G2_174703_0005 MG11_ROSE_2016_171_OP_G2_174703_0006 MG11_ROSE_2016_171_OP_G2_174703_0007 MG11_ROSE_2016_171_OP_G2_174703_0008 MG11_ROSE_2016_171_OP_G2_174703_0009 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191747 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_CL_D2_170704_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 MET-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_ME_172220_0001 MG11_ROSE_2016_171_OP_ME_172220_0002 MG11_ROSE_2016_171_OP_ME_172220_0003 MG11_ROSE_2016_171_OP_ME_172220_0004 MG11_ROSE_2016_171_OP_ME_172220_0005 MG11_ROSE_2016_171_OP_ME_172220_0006 MG11_ROSE_2016_171_OP_ME_172220_0007 MG11_ROSE_2016_171_OP_ME_172220_0008 MG11_ROSE_2016_171_OP_ME_172220_0009 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191822 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_OP_RG_174702_0000.raw MG11_ROSE_2016_171_OP_RG_174702_0001.raw MG11_ROSE_2016_171_OP_RG_174702_0002.raw MG11_ROSE_2016_171_OP_RG_174702_0003.raw MG11_ROSE_2016_171_OP_RG_174702_0004.raw MG11_ROSE_2016_171_OP_RG_174702_0005.raw MG11_ROSE_2016_171_OP_RG_174702_0006.raw MG11_ROSE_2016_171_OP_RG_174702_0007.raw MG11_ROSE_2016_171_OP_RG_174702_0008.raw Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191844 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-Cal-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_171_CL_RG_170704_0000.raw ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_171_OP_D1_184027_0000 MG12_ROSE_2016_171_OP_D1_184027_0001 MG12_ROSE_2016_171_OP_D1_184027_0002 MG12_ROSE_2016_171_OP_D1_184027_0003 MG12_ROSE_2016_171_OP_D1_184027_0004 MG12_ROSE_2016_171_OP_D1_184027_0005 MG12_ROSE_2016_171_OP_D1_184027_0006 MG12_ROSE_2016_171_OP_D1_184027_0007 MG12_ROSE_2016_171_OP_D1_184027_0008 The files cover the following time range 201606191840 - 201606200301 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_171_OP_G1_184027_0000 MG12_ROSE_2016_171_OP_G1_184027_0001 MG12_ROSE_2016_171_OP_G1_184027_0002 MG12_ROSE_2016_171_OP_G1_184027_0003 MG12_ROSE_2016_171_OP_G1_184027_0004 MG12_ROSE_2016_171_OP_G1_184027_0005 MG12_ROSE_2016_171_OP_G1_184027_0006 MG12_ROSE_2016_171_OP_G1_184027_0007 MG12_ROSE_2016_171_OP_G1_184027_0008 The files cover the following time range 201606191840 - 201606200301 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_171_OP_D2_184027_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0000 MG12_ROSE_2016_171_OP_D2_184027_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0001 MG12_ROSE_2016_171_OP_D2_184027_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0002 MG12_ROSE_2016_171_OP_D2_184027_0003 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0003 MG12_ROSE_2016_171_OP_D2_184027_0004 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0004 MG12_ROSE_2016_171_OP_D2_184027_0005 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0005 MG12_ROSE_2016_171_OP_D2_184027_0006 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0006 MG12_ROSE_2016_171_OP_D2_184027_0007 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0007 MG12_ROSE_2016_171_OP_D2_184027_0008 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_171_OP_G2_184027_0000 MG12_ROSE_2016_171_OP_G2_184027_0001 MG12_ROSE_2016_171_OP_G2_184027_0002 MG12_ROSE_2016_171_OP_G2_184027_0003 MG12_ROSE_2016_171_OP_G2_184027_0004 MG12_ROSE_2016_171_OP_G2_184027_0005 MG12_ROSE_2016_171_OP_G2_184027_0006 MG12_ROSE_2016_171_OP_G2_184027_0007 MG12_ROSE_2016_171_OP_G2_184027_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 MET-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_171_OP_ME_172221_0001 MG12_ROSE_2016_171_OP_ME_172221_0002 MG12_ROSE_2016_171_OP_ME_172221_0003 MG12_ROSE_2016_171_OP_ME_172221_0004 MG12_ROSE_2016_171_OP_ME_172221_0005 MG12_ROSE_2016_171_OP_ME_172221_0006 MG12_ROSE_2016_171_OP_ME_172221_0007 MG12_ROSE_2016_171_OP_ME_172221_0008 MG12_ROSE_2016_171_OP_ME_172221_0009 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191822 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 D1-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_171_OP_D1_184028_0000 MG13_ROSE_2016_171_OP_D1_184028_0001 MG13_ROSE_2016_171_OP_D1_184028_0002 MG13_ROSE_2016_171_OP_D1_184028_0003 MG13_ROSE_2016_171_OP_D1_184028_0004 MG13_ROSE_2016_171_OP_D1_184028_0005 MG13_ROSE_2016_171_OP_D1_184028_0006 MG13_ROSE_2016_171_OP_D1_184028_0007 MG13_ROSE_2016_171_OP_D1_184028_0008 The files cover the following time range 201606191840 - 201606200301 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 AGC1-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_171_OP_G1_184028_0000 MG13_ROSE_2016_171_OP_G1_184028_0001 MG13_ROSE_2016_171_OP_G1_184028_0002 MG13_ROSE_2016_171_OP_G1_184028_0003 MG13_ROSE_2016_171_OP_G1_184028_0004 MG13_ROSE_2016_171_OP_G1_184028_0005 MG13_ROSE_2016_171_OP_G1_184028_0006 MG13_ROSE_2016_171_OP_G1_184028_0007 MG13_ROSE_2016_171_OP_G1_184028_0008 The files cover the following time range 201606191840 - 201606200301 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 D2-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_171_OP_D2_184028_0000 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0000 MG13_ROSE_2016_171_OP_D2_184028_0001 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0001 MG13_ROSE_2016_171_OP_D2_184028_0002 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0002 MG13_ROSE_2016_171_OP_D2_184028_0003 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0003 MG13_ROSE_2016_171_OP_D2_184028_0004 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0004 MG13_ROSE_2016_171_OP_D2_184028_0005 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0005 MG13_ROSE_2016_171_OP_D2_184028_0006 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0006 MG13_ROSE_2016_171_OP_D2_184028_0007 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0007 MG13_ROSE_2016_171_OP_D2_184028_0008 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 AGC2-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_171_OP_G2_184028_0000 MG13_ROSE_2016_171_OP_G2_184028_0001 MG13_ROSE_2016_171_OP_G2_184028_0002 MG13_ROSE_2016_171_OP_G2_184028_0003 MG13_ROSE_2016_171_OP_G2_184028_0004 MG13_ROSE_2016_171_OP_G2_184028_0005 MG13_ROSE_2016_171_OP_G2_184028_0006 MG13_ROSE_2016_171_OP_G2_184028_0007 MG13_ROSE_2016_171_OP_G2_184028_0008 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191840 - 201606200300 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 MET-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_171_OP_ME_172221_0001 MG13_ROSE_2016_171_OP_ME_172221_0002 MG13_ROSE_2016_171_OP_ME_172221_0003 MG13_ROSE_2016_171_OP_ME_172221_0004 MG13_ROSE_2016_171_OP_ME_172221_0005 MG13_ROSE_2016_171_OP_ME_172221_0006 MG13_ROSE_2016_171_OP_ME_172221_0007 MG13_ROSE_2016_171_OP_ME_172221_0008 MG13_ROSE_2016_171_OP_ME_172221_0009 Files stop too early at 201606200300 instead of 201606200300 The files cover the following time range 201606191822 - 201606200300 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0003 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0004 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0005 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0006 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0007 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_171_OP_D2_184027_0008 Ranging files for Gravity measurement missing for DOY 171 Ranging CL files for Gravity measurement missing for DOY 171 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0000 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0001 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0002 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0003 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0004 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0005 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0006 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0007 Wrong sample time of 0. for GRV-measurement in MG13_ROSE_2016_171_OP_D2_184028_0008 Ranging files for Gravity measurement missing for DOY 171 Ranging CL files for Gravity measurement missing for DOY 171