This is a logfile for the ros measurement on 221 Times are given in the format YYYYMMDDhhmm GRV Measurement time: 201608081656 - 201608082019 Checking files of DOY 221 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_D1_165606_0000 MG11_ROSE_2016_221_OP_D1_165606_0001 MG11_ROSE_2016_221_OP_D1_165606_0002 MG11_ROSE_2016_221_OP_D1_165606_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_G1_154704_0001 MG11_ROSE_2016_221_OP_G1_154704_0002 MG11_ROSE_2016_221_OP_G1_154704_0003 MG11_ROSE_2016_221_OP_G1_154704_0004 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081647 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_220_CL_D1_141923_0000 MG11_ROSE_2016_221_CL_D1_151156_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_D2_165606_0000 MG11_ROSE_2016_221_OP_D2_165606_0001 MG11_ROSE_2016_221_OP_D2_165606_0002 MG11_ROSE_2016_221_OP_D2_165606_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_G2_154704_0001 MG11_ROSE_2016_221_OP_G2_154704_0002 MG11_ROSE_2016_221_OP_G2_154704_0003 MG11_ROSE_2016_221_OP_G2_154704_0004 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081647 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_220_CL_D2_141923_0000 MG11_ROSE_2016_221_CL_D2_151156_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 MET-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_ME_152120_0001 MG11_ROSE_2016_221_OP_ME_152120_0002 MG11_ROSE_2016_221_OP_ME_152120_0003 MG11_ROSE_2016_221_OP_ME_152120_0004 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081621 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_221_OP_RG_154703_0000.raw MG11_ROSE_2016_221_OP_RG_154703_0001.raw MG11_ROSE_2016_221_OP_RG_154703_0002.raw MG11_ROSE_2016_221_OP_RG_154703_0003.raw Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081659 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-Cal-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_220_CL_RG_141923_0000.raw MG11_ROSE_2016_221_CL_RG_151156_0000.raw ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_221_OP_D1_165607_0000 MG12_ROSE_2016_221_OP_D1_165607_0001 MG12_ROSE_2016_221_OP_D1_165607_0002 MG12_ROSE_2016_221_OP_D1_165607_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_221_OP_G1_165607_0000 MG12_ROSE_2016_221_OP_G1_165607_0001 MG12_ROSE_2016_221_OP_G1_165607_0002 MG12_ROSE_2016_221_OP_G1_165607_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_221_OP_D2_165607_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0000 MG12_ROSE_2016_221_OP_D2_165607_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0001 MG12_ROSE_2016_221_OP_D2_165607_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0002 MG12_ROSE_2016_221_OP_D2_165607_0003 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_221_OP_G2_165607_0000 MG12_ROSE_2016_221_OP_G2_165607_0001 MG12_ROSE_2016_221_OP_G2_165607_0002 MG12_ROSE_2016_221_OP_G2_165607_0003 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081656 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 MET-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_221_OP_ME_152121_0001 MG12_ROSE_2016_221_OP_ME_152121_0002 MG12_ROSE_2016_221_OP_ME_152121_0003 MG12_ROSE_2016_221_OP_ME_152121_0004 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081621 - 201608082019 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 MET-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_221_OP_ME_152122_0001 MG13_ROSE_2016_221_OP_ME_152122_0002 MG13_ROSE_2016_221_OP_ME_152122_0003 MG13_ROSE_2016_221_OP_ME_152122_0004 Files stop too early at 201608082019 instead of 201608082019 The files cover the following time range 201608081621 - 201608082019 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_221_OP_D2_165607_0003 Ranging files for Gravity measurement missing for DOY 221 Ranging CL files for Gravity measurement missing for DOY 221 MG13 D1 for DOY 221 missing in Z:/incoming/ros/ Gravity measurement is missing S-BAND: Possible Fatal Error! MG13 AGC1 for DOY 221 missing MG13 D2 for DOY 221 missing in Z:/incoming/ros/ Gravity measurement is missing S-BAND: Possible Fatal Error! MG13 AGC2 for DOY 221 missing Ranging files for Gravity measurement missing for DOY 221 Ranging CL files for Gravity measurement missing for DOY 221