This is a logfile for the ros measurement on 232 Times are given in the format YYYYMMDDhhmm GRV Measurement time: 201608191526 - 201608192306 Checking files of DOY 232 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_D1_152629_0000 MG11_ROSE_2016_232_OP_D1_152629_0001 MG11_ROSE_2016_232_OP_D1_152629_0002 MG11_ROSE_2016_232_OP_D1_152629_0003 MG11_ROSE_2016_232_OP_D1_152629_0004 MG11_ROSE_2016_232_OP_D1_152629_0005 MG11_ROSE_2016_232_OP_D1_152629_0006 MG11_ROSE_2016_232_OP_D1_152629_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_G1_141433_0001 MG11_ROSE_2016_232_OP_G1_141433_0002 MG11_ROSE_2016_232_OP_G1_141433_0003 MG11_ROSE_2016_232_OP_G1_141433_0004 MG11_ROSE_2016_232_OP_G1_141433_0005 MG11_ROSE_2016_232_OP_G1_141433_0006 MG11_ROSE_2016_232_OP_G1_141433_0007 MG11_ROSE_2016_232_OP_G1_141433_0008 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191514 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_231_CL_D1_134247_0000 MG11_ROSE_2016_232_CL_D1_133927_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_D2_152629_0000 MG11_ROSE_2016_232_OP_D2_152629_0001 MG11_ROSE_2016_232_OP_D2_152629_0002 MG11_ROSE_2016_232_OP_D2_152629_0003 MG11_ROSE_2016_232_OP_D2_152629_0004 MG11_ROSE_2016_232_OP_D2_152629_0005 MG11_ROSE_2016_232_OP_D2_152629_0006 MG11_ROSE_2016_232_OP_D2_152629_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 AGC2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_G2_141433_0001 MG11_ROSE_2016_232_OP_G2_141433_0002 MG11_ROSE_2016_232_OP_G2_141433_0003 MG11_ROSE_2016_232_OP_G2_141433_0004 MG11_ROSE_2016_232_OP_G2_141433_0005 MG11_ROSE_2016_232_OP_G2_141433_0006 MG11_ROSE_2016_232_OP_G2_141433_0007 MG11_ROSE_2016_232_OP_G2_141433_0008 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191514 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_231_CL_D2_134247_0000 MG11_ROSE_2016_232_CL_D2_133927_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG11 MET-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_ME_134849_0001 MG11_ROSE_2016_232_OP_ME_134849_0002 MG11_ROSE_2016_232_OP_ME_134849_0003 MG11_ROSE_2016_232_OP_ME_134849_0004 MG11_ROSE_2016_232_OP_ME_134849_0005 MG11_ROSE_2016_232_OP_ME_134849_0006 MG11_ROSE_2016_232_OP_ME_134849_0007 MG11_ROSE_2016_232_OP_ME_134849_0008 MG11_ROSE_2016_232_OP_ME_134849_0009 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191449 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_232_OP_RG_141432_0000.raw MG11_ROSE_2016_232_OP_RG_141432_0001.raw MG11_ROSE_2016_232_OP_RG_141432_0002.raw MG11_ROSE_2016_232_OP_RG_141432_0003.raw MG11_ROSE_2016_232_OP_RG_141432_0004.raw MG11_ROSE_2016_232_OP_RG_141432_0005.raw MG11_ROSE_2016_232_OP_RG_141432_0006.raw MG11_ROSE_2016_232_OP_RG_141432_0007.raw Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191530 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-Cal-files ++++++++++++++++++++++++++++++++++++ MG11_ROSE_2016_231_CL_RG_134247_0000.raw MG11_ROSE_2016_232_CL_RG_133927_0000.raw ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_232_OP_D1_152630_0000 MG12_ROSE_2016_232_OP_D1_152630_0001 MG12_ROSE_2016_232_OP_D1_152630_0002 MG12_ROSE_2016_232_OP_D1_152630_0003 MG12_ROSE_2016_232_OP_D1_152630_0004 MG12_ROSE_2016_232_OP_D1_152630_0005 MG12_ROSE_2016_232_OP_D1_152630_0006 MG12_ROSE_2016_232_OP_D1_152630_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC1-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_232_OP_G1_152630_0000 MG12_ROSE_2016_232_OP_G1_152630_0001 MG12_ROSE_2016_232_OP_G1_152630_0002 MG12_ROSE_2016_232_OP_G1_152630_0003 MG12_ROSE_2016_232_OP_G1_152630_0004 MG12_ROSE_2016_232_OP_G1_152630_0005 MG12_ROSE_2016_232_OP_G1_152630_0006 MG12_ROSE_2016_232_OP_G1_152630_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 D2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_232_OP_D2_152630_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0000 MG12_ROSE_2016_232_OP_D2_152630_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0001 MG12_ROSE_2016_232_OP_D2_152630_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0002 MG12_ROSE_2016_232_OP_D2_152630_0003 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0003 MG12_ROSE_2016_232_OP_D2_152630_0004 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0004 MG12_ROSE_2016_232_OP_D2_152630_0005 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0005 MG12_ROSE_2016_232_OP_D2_152630_0006 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0006 MG12_ROSE_2016_232_OP_D2_152630_0007 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 AGC2-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_232_OP_G2_152630_0000 MG12_ROSE_2016_232_OP_G2_152630_0001 MG12_ROSE_2016_232_OP_G2_152630_0002 MG12_ROSE_2016_232_OP_G2_152630_0003 MG12_ROSE_2016_232_OP_G2_152630_0004 MG12_ROSE_2016_232_OP_G2_152630_0005 MG12_ROSE_2016_232_OP_G2_152630_0006 MG12_ROSE_2016_232_OP_G2_152630_0007 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191526 - 201608192306 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG12 MET-files ++++++++++++++++++++++++++++++++++++ MG12_ROSE_2016_232_OP_ME_134850_0001 MG12_ROSE_2016_232_OP_ME_134850_0002 MG12_ROSE_2016_232_OP_ME_134850_0003 MG12_ROSE_2016_232_OP_ME_134850_0004 MG12_ROSE_2016_232_OP_ME_134850_0005 MG12_ROSE_2016_232_OP_ME_134850_0006 MG12_ROSE_2016_232_OP_ME_134850_0007 MG12_ROSE_2016_232_OP_ME_134850_0008 MG12_ROSE_2016_232_OP_ME_134850_0009 Files stop too early at 201608192305 instead of 201608192306 The files cover the following time range 201608191448 - 201608192305 ++++++++++++++++++++++++++++++++++++ Sorting and checking MG13 MET-files ++++++++++++++++++++++++++++++++++++ MG13_ROSE_2016_232_OP_ME_134851_0001 MG13_ROSE_2016_232_OP_ME_134851_0002 MG13_ROSE_2016_232_OP_ME_134851_0003 MG13_ROSE_2016_232_OP_ME_134851_0004 MG13_ROSE_2016_232_OP_ME_134851_0005 MG13_ROSE_2016_232_OP_ME_134851_0006 MG13_ROSE_2016_232_OP_ME_134851_0007 MG13_ROSE_2016_232_OP_ME_134851_0008 MG13_ROSE_2016_232_OP_ME_134851_0009 Files stop too early at 201608192306 instead of 201608192306 The files cover the following time range 201608191448 - 201608192306 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0000 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0001 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0002 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0003 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0004 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0005 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0006 Wrong sample time of 0. for GRV-measurement in MG12_ROSE_2016_232_OP_D2_152630_0007 Ranging files for Gravity measurement missing for DOY 232 Ranging CL files for Gravity measurement missing for DOY 232 MG13 D1 for DOY 232 missing in Z:/incoming/ros/ Gravity measurement is missing S-BAND: Possible Fatal Error! MG13 AGC1 for DOY 232 missing MG13 D2 for DOY 232 missing in Z:/incoming/ros/ Gravity measurement is missing S-BAND: Possible Fatal Error! MG13 AGC2 for DOY 232 missing Ranging files for Gravity measurement missing for DOY 232 Ranging CL files for Gravity measurement missing for DOY 232