PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 2019-11-30 NOTE = "Description of the DOCUMENT directory contents for a VIRTIS release." END_OBJECT = TEXT END DOCUMENT Directory Contents The DOCUMENT directory contains documentation files for a VIRTIS ROSETTA archive volume. The files listed below are found in this directory. DOCINFO.TXT - The file you are reading. RO_VIRTIS_EAICD.PDF - Adobe Acrobat version of EAICD The EAICD (Experimenter to (Science) Archive Interface Control Document) provides users of the VIRTIS instrument with detailed description of the product and a description of how it was generated, including data sources and destinations. It is the official interface between our instrument team and the archiving authority. RO_VIRTIS_EAICD.ASC - Text version of EAICD VIRTIS_EXP_USER_MANUAL.PDF - Adobe Acrobat version of Virtis User Manual VIRTIS_M_CALIBRATION_REPORT.ASC - Calibration documentation for M Visible and Infrared channels VIRTIS_M_CALIBRATION_REPORT.PDF - Adobe Acrobat version of calibration documentation for M channel VIRTIS_H_CALIBRATION.PDF - Adobe Acrobat version of calibration documentation for H channel VIRTIS_H_CALIBRATION.ASC - Text version of calibration documentation for H channel VIRTIS_PDS_IDL_SW_MANUAL.PDF - Documentation of IDL package to work with VIRTIS data VIRTISROS_GEOMETRY.PDF - VIRTIS - Rosetta geometry files documentation IMAGE001.PNG - RO_VIRTIS_EAICD.ASC: VIRTIS functional block diagram IMAGE002.PNG - RO_VIRTIS_EAICD.ASC: Data Organization on the CCD and IR detectors of VIRTIS-M IMAGE003.PNG - RO_VIRTIS_EAICD.ASC: Spectral orders distributed over the IR FPA area. Only 15% of the matrix contains scientific data IMAGE004.PNG - RO_VIRTIS_EAICD.ASC: VIRTIS/Rosetta data set generation IMAGE005.PNG - RO_VIRTIS_EAICD.ASC: Standard PDS volume set organization: one data set, one volume IMAGE006.PNG - RO_VIRTIS_EAICD.ASC: Structure of the qube data IMAGE007.PNG - RO_VIRTIS_EAICD.ASC: Structure of dark frames acquisition IMAGE008.PNG - RO_VIRTIS_EAICD.ASC: VIRTIS H data cube in 64-spectra mode. In this case, each frame contains the 64 spectra transferred together. The # of bands is equal to 3456 IMAGE009.PNG - RO_VIRTIS_EAICD.ASC: Organization of the sideplanes IMAGE010.PNG - VIRTIS_H_CALIBRATION.ASC: Example of dark corruption IMAGE011.PNG - VIRTIS_H_CALIBRATION.ASC: ADU vs. integration time at constant flux IMAGE012.PNG - VIRTIS_H_CALIBRATION.ASC: Number of ADU/s vs. flux at constant charge IMAGE013.PNG - VIRTIS_H_CALIBRATION.ASC: Recovering the integration time to get ADUref when lightning with PHIi IMAGE014.PNG - VIRTIS_H_CALIBRATION.ASC: Recovering the incident flux PHIi IMAGE015.PNG - VIRTIS_H_CALIBRATION.ASC: Transfer function synopsis IMAGE016.PNG - VIRTIS_H_CALIBRATION.ASC: Formula 1 IMAGE017.PNG - VIRTIS_H_CALIBRATION.ASC: Plot of the transfer function for each order. Units are (Niv_KIT / s) / (W_IAS / sr / m2 / um) IMAGE018.PNG - VIRTIS_H_CALIBRATION.ASC: Raw data calibration IMAGE019.PNG - VIRTIS_H_CALIBRATION.ASC: Formula 2 IMAGE020.PNG - VIRTIS_H_CALIBRATION.ASC: Formula 3 IMAGE021.PNG - VIRTIS_H_CALIBRATION.ASC: IDL programs flow chart IMAGE022.PNG - VIRTIS_H_CALIBRATION.ASC: Emission of the Fabry-Perot spectral lines in each order IMAGE023.PNG - VIRTIS_H_CALIBRATION.ASC: Flow chart of the spectral registration function IMAGE024.PNG - VIRTIS_H_CALIBRATION.ASC: Formula 4 IMAGE025.PNG - VIRTIS_H_CALIBRATION.ASC: Spectral response at 2 micron, order 8 IMAGE026.PNG - VIRTIS_H_CALIBRATION.ASC: Example of radiance spectrum of the comet affected by stray light IMAGE027.PNG - VIRTIS_H_CALIBRATION.ASC: Spectral response at 5 micron, order 0 IMAGE028.PNG - VIRTIS_H_CALIBRATION.ASC: Plot of the spectral profile through order 0