DATE ,TIME,INTLs,KEYWORD,PURPOSE,ACTIVITY DETAILS ,,,,, ,,,,,File: MIRO_Log_Book_17.xls ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, Tuesday,,,,,For past activities refer to MIRO_LOG_book_16B 15/5/01,17:30:00,,Pump down,CTS Failure test,Remove SBEU from chamber and pump down. 15/5/01,,,,,Place SBEU in the oven and set oven to 54 deg c at 30 deg/hr. 15/5/01,18:30,,SBEU TEMP,,SBEU is at +53.8 degrees. 15/5/01,18:37,,,,Chamber vacuum = 2.7 -5. 15/5/01,18:38:31,,Power on 199,,Verify EU is working before going cold. Iin = .46 amps. 15/5/01,18:40:56,,,, 15/5/01,,,,,Mode change to CTS dual. 15/5/01,18:44,,,,"Verify noise source power supply is 12 volts. Power on, Iin 340 ma." 15/5/01,18:44:07,,,,Mode change to ENG. 15/5/01,18:52:12,,Power off 199,,Power off noise amplifier. 15/5/01,18:55,,set temp,,Set large heat exchanger from +23 to +10 degrees. 15/5/01,,,,,Chamber vacuum 1.1 -5. 15/5/01,19:15,,set temp,,Set large heat exchanger from +10 to +5 degrees. 15/5/01,19:25,,,,"Temps CTS ft +11.11, CTS top +16.43, EU +10.63, USO +12.98, CPU +11.26, Lg Heat ex. +6.05" 15/5/01,19:25:40,,Power on 200,,Vin = 28.4 Iin = 0.47 amps. 15/5/01,19:30:00,rn,,load software,into ram vxWorks_051501_ctsdiag_2.bin 15/5/01,19:31,,set temp,,Set large heat exchanger from +5 to 0. 15/5/01,19:38:00,ap,,,Power on the Power supply for CTS signal source. 15/5/01,19:45:00,,set temp,,Set large heat exchanger from +0 to -5.0 15/5/01,19:47:00,,,,"CTS ft +5.19, CTS top +11.31, EU +5.95, USO +6.2, CPU +5.35, Lg Heat ex. -2.11" 15/5/01,,maf,,,change mode CTS/Dua 15/5/01,,,set temp,,Set large heat exchanger from -5 to -10 degrees. 15/5/01,20:00:08,,cmd,,"Mode change to CTS dual., T5=2.85, T6=6.92" 15/5/01,,,,,"CTS ft 0.32, CTS top 7.87, EU 1.43, USO 1.12, CPU 0.354, Lg Heat ex. -7.751" 15/5/01,20:05:00,,power off 200,,adjust test software 15/5/01,20:07:00,,,,turned off CTS signal amplifier 15/5/01,20:07:20,,power on 201,,loading software 15/5/01,20:08:00,,.,,turn on CTS signal amplifier 15/5/01,20:23:10,,power off 201,, 15/5/01,20:23:25,,power on 202,,"works with regular software, it works" 15/5/01,20:25:00,,,,"CTS ft -4.17, CTS top 3.26, EU -2.06, USO -3.89, CPU -2.97, Lg Heat ex.-8.9" 15/5/01,20:26:23,,cmd,,"mode change to CTS/dual Spect T5=-2.84, Spect T6=1.32 CAL INT midpoints OK" 15/5/01,20:26:53,,power off 202,, 15/5/01,20:29:24,,power on 203,,loading test program 15/5/01,20:31:00,,set temp,,Set large heat exchanger from -10 to -15 degrees. 15/5/01,20:31:10,,power off 203,, 15/5/01,20:31:20,,power on 204,,"BIST had to be started, loading test software" 15/5/01,20:45:00,,,,"CTS ft -8.12, CTS top 0.67, EU -6.23, USO -7.89, CPU -7.027, Lg Heat ex.-14.01" 15/5/01,20:46:34,,power off 204,, 15/5/01,20:46:50,,power on 205,,BIST had to be started 15/5/01,21:04:20,,cmd,,"changed mode to CTS/dual Spect T5=-8.2, Spect T6=-3.8, table loaded correctly, data out of CTS for Table 4 is bad" 15/5/01,21:09:06,,cmd,,"CTS Internal Calibration, Table is OK" 15/5/01,21:14:49,,cmd,,mode change to ENG 15/5/01,21:24:00,,set temp,,Set large heat exchanger from -15 to -20 degrees. 15/5/01,21:28:20,,cmd,,"CTS warm up, T=30, power =low" 15/5/01,21:33:33,,cmd,,"CTS/dual, T5=-10.4, T6=-4.4, mid points are fine" 15/5/01,21:36:27,,cmd,,change mode to ENG 15/5/01,21:40:00,,set temp,,Set large heat exchanger from -20 to -25 degrees. 15/5/01,21:48:51,,cmd,,"CTS warm up, T=30, power =low" 15/5/01,21:54:09,,cmd,,"CTS/dual, T5=-14.4, T6=-7.8, mid points are OK" 15/5/01,21:57:00,,set temp,,Set large heat exchanger from -25 to -30 degrees. 15/5/01,21:57:26,,cmd,,change mode to ENG 15/5/01,22:07:41,,cmd,,"CTS warm up, T=30, power =low" 15/5/01,22:13:21,,cmd,,"CTS/dual, T5=-18.8, T6=-11.8, mid points are ok" 15/5/01,22:16:00,,set temp,,Set large heat exchanger from -30 to -35 degrees. 15/5/01,22:17:00,,cmd,,change mode to ENG 15/5/01,22:28:45,,cmd,,"CTS/dual, T5=-20.8, T6=-15.2, mid points are ok " 15/5/01,22:33:00,,set temp,,Set large heat exchanger from -35 to -40 degrees. 15/5/01,22:33:00,,cmd,,change mode to ENG 15/5/01,22:53:10,,cmd,,"CTS/dual, T5=-20.8???, T6=-20.0???, mid points are OK " 15/5/01,13:00:00,,set temp,,Set large heat exchanger from -40 to -30 degrees. 15/5/01,23:00:00,,power off 205,, 15/5/01,23:01:00,,,,TURN OFF cts AMPLIFIER 16/5/01,9:15:10,,power on 206,,BIST needs to restarted Wednesday,9:17:12,,cmd,,"change mode to CTS/dual, table 4 failed, CTS foot =-23.7, EU Int=-22.8, USO foot=-24.9, CPU Int=-25.18" 16/5/01,9:18:23,,power off 206,, 16/5/01,9:21:00,,,,Turn on CTS amplifier 16/5/01,9:38:01,,power on 207,,BIST needed to be restarted 16/5/01,9:40:16,,cmd,,"change mode to CTS/dual, table 4 it worked, CTS foot =-23.7, EU Int=-23.0, USO foot=-24.8, CPU Int=-25.1" 16/5/01,9:41:13,,power off 207,, 16/5/01,10:30:30,,power on 208,, 16/5/01,10:32:37,,cmd,,"change mode to CTS/dual, table 4 failed , CTS foot =-23.7, EU Int=-23.4, USO foot=-24.8, CPU Int=-25.2" 16/5/01,10:35:00,,power off 208,, 16/5/01,11:04:08,,power on 209,,BIST had to be restarted 16/5/01,11:06:13,,cmd,,"change mode to CTS/dual, table 4 failed , CTS foot =-23.7, EU Int=-23.4, USO foot=-24.7, CPU Int=-25.2" 16/5/01,11:07:05,,power off 209,, 16/5/01,11:37:05,,power on 210,,BIST had to be started 16/5/01,11:39:09,,cmd,,"CTS warm up, T=30, power=low" 16/5/01,11:44:14,,cmd,,"change mode to CTS/dual, table 4 works , CTS foot =-23.3, EU Int=-21.97, USO foot=24.76, CPU Int=-24.82" 16/5/01,11:45:13,,power off 210,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,,,,, 16/5/01,12:43:17,RN,power on 211,,To test failure case again 16/5/01,12:45:25,RN,mode change,,CTS dual 16/5/01,12:47:50,RN,power off 211,,Failed CTS table init as expected 16/5/01,13:25:58,RN,power on 212,,"To test failure case - will warm up CTS at 0 deg, low power first" 16/5/01,13:28:29,RN,cmd,,"CTS Warmup, 0 deg, low power for 5 minutes" 16/5/01,13:33:36,RN,cmd,,"change mode to CTS/dual, table 4 works , CTS foot =-23.34, EU Int=-21.9, USO foot=24.74, CPU Int=-24.83" 16/5/01,,,,,Table load successful 16/5/01,13:34:33,RN,power off 212,, 16/5/01,14:13:44,CK,Power on 213,,To test failure case again 16/5/01,14:16:21,CK,cmd,,CTS dual 16/5/01,14:17:00,CK,,,Failed CTS table init as expected 16/5/01,14:17:47,CK,Power off 213,, 16/5/01,14:49:00,CK,Power on 214,,"To test failure case - will warm up CTS at 0 deg, low power first" 16/5/01,14:51:25,CK,cmd,,"CTS Warmup, 0 deg, low power for 5 minutes" 16/5/01,14:56:00,CK,cmd,,CTS dual 16/5/01,,,,, 16/5/01,,,,, 16/5/01,14:58:45,CK,cmd,,Submm Auto Control Enable/Disable Enabled 16/5/01,14:59:25,CK,cmd,,Submm Auto Control Enable/Disable Disabled 16/5/01,15:01:00,CK,cmd,,CTS Heaters off 16/5/01,15:02:00,CK,cmd,,Mode change to Engineering 16/5/01,15:04:12,CK,Power off 214,, 16/5/01,15:35:28,CK,Power on 215,,Testing without Amplifier on to see if failure still occurs - request by Christopher Jarchow 16/5/01,15:37:45,CK,cmd,,CTS Dual 16/5/01,,,,,Failed CTS table init 16/5/01,15:38:55,CK,Power off 215,, 16/5/01,15:40:00,,,,Turning off temperature control in chamber. Will let plates drift to ambient. 16/5/01,,,,, 17-May-01,10:00:00,,,,open chamber Thursday,10:26:23,,power on 216,,Loading eeprom with vxWorks_051701_ee.bin 17/5/01,10:43:00,,power off 216,, 17/5/01,,,,, 17/5/01,12:41:50,,power on 215,,"V=28.4, I=.70 (note different from 0.66)" 17/5/01,13:00:40,,power off 215,, 17/5/01,13:03:20,,power on 216,,"V=28.4, I=1.15 to 0.92 to 0.71" 17/5/01,13:10:56,,power off 216,, 17/5/01,,,,, 17/5/01,,TCK,,,+5V SBEU is 277mA should be 124mA: 153mA extra in Eng Mode 17/5/01,,,,,looks like it only happens when IFP pwr =3 but not =0 17/5/01,,,,,could be short in IFP but ctrl lines are tri-stated... short in SBEU? 17/5/01,,,,, 17/5/01,13:43:58,,Power on 217,,"Troubleshooting current problem, +5V SBEU CUR = .278A when usually was .124A" 17/5/01,,,,,Loading ram with vxWorks_051501_ctsdiag_2.bin 17/5/01,,,,,checking out new settings in SW 17/5/01,14:02:06,,cmd,,"IFP Power level to 3, +5V SBEU CUR = .280" 17/5/01,14:07:44,,cmd,,"IFP Power level to 0, +5V SBEU CUR = .124" 17/5/01,14:12:33,,cmd,,mode change CTS/dual 17/5/01,14:18:09,,cmd,,mode change to ENG 17/5/01,14:26:00,CK+PF,LFT,,running limited Functional Test 17/5/01,,,,, 17/5/01,15:14:00,DN,EGSE S/W,Upgrade,Quicklook v4.8 engineering plot change. 17/5/01,15:44:00,CK,,,Finished Limited Functional Test Post Vibe for SBEU 17/5/01,15:44:19,MF,cmd,,CTS/Dual 17/5/01,15:48:51,MF,cmd,,CTS/Dual 17/5/01,15:51:13,MF,cmd,,CTS/Dual 17/5/01,15:55:28,MF,cmd,,Mode change to Engineering 17/5/01,,,,, 17/5/01,,,,,Note: IFP pwr lvl at zero 17/5/01,,,,, 17/5/01,15:56:32,,cmd,,USO power off 17/5/01,,,,,28.4V*0.82A 17/5/01,15:58:09,,cmd,,CTS calibration heater off (hot load) 17/5/01,,,,,28.4V*0.66A 17/5/01,15:58:43,,cmd,,CTS warmup heater off 17/5/01,,,,,28.4V*1.11A 17/5/01,15:59:54,,cmd,,CTS warmup heater low; 0 deg 17/5/01,,,,,28.4V*1.11A 17/5/01,16:04:49,,cmd,,mode change to eng 17/5/01,,,,,28.4V*0.66A 17/5/01,,,,,+5V SBEU 0.142A 17/5/01,16:06:19,,cmd,,IFP pwr lvl=1 17/5/01,,,,,28.4V*0.68 17/5/01,,,,,+5V SBEU 0.223A 17/5/01,16:08:02,,cmd,,IFP pwr lvl=2 17/5/01,,,,,28.4V*0.68 17/5/01,,,,,+5V SBEU 0.223A 17/5/01,16:09:59,,cmd,,IFP pwr lvl=4 17/5/01,,,,,28.4V*0.68 17/5/01,,,,,+5V SBEU 0.222A 17/5/01,16:10:51,,cmd,,IFP pwr lvl=8 17/5/01,,,,,28.4V*0.68A 17/5/01,,,,,+5V SBEU 0.223A 17/5/01,16:11:55,,cmd,,IFP pwr lvl=0 17/5/01,,,,,28.4V*0.66A 17/5/01,,,,,+5V SBEU 0.142A 17/5/01,16:13:09,,cmd,,IFP pwr lvl=15 17/5/01,,,,,28.4V*0.72A 17/5/01,,,,,+5V SBEU 0.415A 17/5/01,16:14:08,,cmd,,IFP pwr lvl=0 17/5/01,,,,,28.4V*0.72A 17/5/01,,,,,+5V SBEU 0.415A 17/5/01,16:16:18,,Power Off 217,, 17/5/01,,,,, 17/5/01,,TCK,note,,looks like each bit draws a lot of current! 17/5/01,,,,, 17/5/01,,,configuration,,BOB#1 SBEU.J6 and BOB#2 on SBEU.J5 17/5/01,,,,,"BOB#1 tied pins 1, 5, 7 for ground" 17/5/01,,,,,demate SBEU.J9; short W11 with shorting plug 17/5/01,,,,,demate SBEU.J7 17/5/01,,,mate/demate,,AIDS#216837 Step#580 17/5/01,,,,, 17/5/01,16:24:00,DN,EGSE S/W,Upgrade,"Sci File Generator v4.4; complete separation of asteroid, calibration and normal CTS decoding" 17/5/01,16:24:00,DN,EGSE S/W,Upgrade,"RWS Interface v4.9; SMM Gunn voltage default is 4, CTS pulse position, heater control, and internal calibration command ACK field set to 9, all others set to 1" 17/5/01,,,,, 17/5/01,16:49:20,,Power on 218,,V = 28.4 I = 0.66 17/5/01,,,,,IFP Power level set to 3 in boot software (EEPROM) 17/5/01,,,,,"Current is normal, not increased as previously" 17/5/01,,,,,+5 SBEU Current = 0.097 A 17/5/01,,,,,IFP Control 1 = 5 V 17/5/01,,,,,IFP Control 2 = 5 V 17/5/01,,,,,IFP Control 3 and 4 = 0 V 17/5/01,16:55:04,,cmd,,IFP command to 0 17/5/01,,,,,V = 28.4 I = 0.65 17/5/01,,,,,No change 17/5/01,16:57:47,,cmd,,IFP command to 0 17/5/01,,,,,No change 17/5/01,16:59:37,,cmd,,IFP pwr lvl=15 17/5/01,,,,, 17/5/01,17:08:00,DN,EGSE S/W,,Changed RWS Interface back to v4.8. IFP command failing. 17/5/01,,,,, 17/5/01,17:09:53,DN,cmd,,IFP power = 0; command succeeded 17/5/01,17:11:56,CK,cmd,,IFP power = 15 17/5/01,,,,, 17/5/01,17:14:06,,cmd,,"phase lock reset = on , changed to +5V" 17/5/01,17:15:01,,cmd,,"phase lock reset = off , changed to 0V" 17/5/01,,,,, 17/5/01,,,,,J5 14 low 17/5/01,,,,,J5 15 low 17/5/01,,,,,J5 29 low 17/5/01,,,,,J5 43 low 17/5/01,,,,, 17/5/01,17:17:18,,Power off 218,,smmGDO bias = 15 17/5/01,,,,, 17/5/01,,,,,J5 14 low 17/5/01,,,,,J5 15 low 17/5/01,,,,,J5 29 low 17/5/01,,,,,J5 43 low 17/5/01,,,,, 17/5/01,19:00:00,rn,,Replace computer,Serial #37 is now installed for debugging VME bus problem 17/5/01,19:38:00,rn,Power on 219,, 17/5/01,19:41:31,rn,Power off 219,,Got immediate data storage interrupts at ambient 17/5/01,19:43:00,,,,disable service 9 time synch. 17/5/01,19:44:25,,Power on 220,,28.4V @ .65A 17/5/01,19:48:00,rn,,,sw running fine without time updates from sis 17/5/01,19:49:00,rn,,,turned time updates on 17/5/01,19:53:47,rn,,,ran ok whole time 17/5/01,19:54:00,rn,power off 220,, 17/5/01,19:54:20,rn,power on 221,,"with time synchs on, trying to reproduce original failure" 17/5/01,19:56:55,rn,power off 221,, 17/5/01,,rn,,,connecting logic analyzer to look at VME bus signals 17/5/01,20:06:25,rn,power on 222,,"logic analyzer connected, time synchs still on" 17/5/01,,,,,Instrument ran fine no failure. 17/5/01,20:14:05,,power off 222,, 17/5/01,20:15:15,rn,power on 223,, 17/5/01,20:18:00,,,,Set large heat exchanger from amb. To +30. 17/5/01,20:35:00,rn,,,Set large heat exchanger from 30. To +35. 17/5/01,20:50:00,,,,Set large heat exchanger from 35 to +40. ,,,,,Descovered thatl TC 214 was not reinstalled. Installed at foot of CPU. 17/5/01,21:05:00,,,,Set large heat exchanger from 40 to +45. 17/5/01,21:15:00,,,,Set large heat exchanger from 45 to +50. 17/5/01,21:30:00,,,,Set large heat exchanger from 50 to +55. 17/5/01,21:40:00,,,,Set large heat exchanger from 55 to +60. 17/5/01,22:07:00,,,,Set large heat exchanger from 60 to +65. 17/5/01,22:11:27,,power off 223,, 17/5/01,22:11:50,,power on 224,,To see if we could get failure to occur by power off and on 17/5/01,22:14:50,,power off 224,,Still no failure ,,,,,Remove BOB from SBEU:J5 and J6 ,,,,,Mate W20 P/J5 and P/J6 ,,,,,Remove shorting bar from P9 ,,,,,Mate P9 to J9 and P7 to J7 on SBEU 17/5/01,22:20:20,,Power on 225,, ,,,,,Boot up normal I = 0.66 A 17/5/01,22:21:46,,cmd,,Mode Change to Dual Continuum ,,,,,Removed IACK line monitor on logic analyzer 17/5/01,22:31:33,,cmd,,Mode change to CTS/Dual Continuum 17/5/01,22:38:37,,cmd,,Mode change to Engineering 17/5/01,22:40:25,,Power off 225,,To remove logic analyzer pins from connector 17/5/01,22:41:25,,Power on 226,, 17/5/01,22:43:09,,cmd,,Mode change to Dual Continuum ,22:44:00,,Failed,,Failed ,,,,,"CPU connector 49.351, EU 59.35, USO 51.15, CPU I/F 57.64, Heat EX 64.99" 17/5/01,22:45:10,,Power off 226,, ,,,,,Putting analyzer bits 11 - 7 and ground only 17/5/01,22:49:10,,Power on 227,, ,22:50:00,,Failed,,Failed 17/5/01,22:53:35,,Power off 227,, 17/5/01,22:53:50,,Power on 228,, 17/5/01,22:56:00,,,,Set large heat exchanger from 65 to +63. 17/5/01,22:57:24,,cmd,,Mode change to Dual Continuum 17/5/01,22:59:00,,Failed,,Failed 17/5/01,23:01:03,,power off 228,, 17/5/01,23:03:00,,,,"CPU connector 49.94, EU 57.35, USO 50.83, CPU I/F 56.43, Heat EX 61.96" ,,,,,Testing without time update interrupt to see if failure still induced with no interrupts reaching CPU. 17/5/01,23:13:40,,Power on 229,, 17/5/01,23:17:04,,cmd,,Mode change to Dual Continuum 17/5/01,23:17:49,,cmd,,Mode change to Engineering 17/5/01,23:25:00,,,,Set large heat exchanger from 63 to +65. 17/5/01,23:32:16,,,,Turning time update on - generate interrupts 17/5/01,23:35:48,,cmd,,Mode change to Dual Continuum 17/5/01,23:47:13,,,,Mode change to Engineering 17/5/01,23:48:00,,Power off 229,, ,,,,,Removed analyzer pins 17/5/01,23:48:35,,Power on 230,, 17/5/01,23:52:16,,cmd,,Mode change to Dual Continuum 17/5/01,23:56:37,rn,cmd,,CTS/Dual ,,,,, Friday,,,,, 18/5/01,0:06:00,,,,Mode change to Engineering 18/5/01,0:07:15,,Power off 230,, 18/5/01,0:10:00,,,,Set large heat exchanger from 65 to +50. 18/5/01,,,,, 18/5/01,9:20:00,DN,ROSIS,Time Set,ROSIS time was 3 minutes behind PC time. Reset. 18/5/01,,,,, 18/5/01,9:22:00,,,,Note: power was never turned off from last power on at 23:48:35 18/5/01,,,,, 18/5/01,9:23:35,DN/RI,Power off 230,, 18/5/01,,,,, 18/5/01,9:25:00,DN,EGSE S/W,Upgrade,"RWS Interface program v4.9; PUS/ACK field changed to set ACK field to 9 for CTS heater control, pulse position, and internal calibration commands." 18/5/01,9:25:00,DN,EGSE S/W,Upgrade,"Science File Generator v4.4; New CTS decoding, total separation of asteroid mode from calibration mode from normal CTS." 18/5/01,10:01:00,RN,,,Heat exchanger to +55 18/5/01,10:12:00,RN,Power on 231,, 18/5/01,10:16:01,DN,cmd,,mode change = engineering mode 18/5/01,10:20:08,DN,cmd,,CTS pulse position = 412 18/5/01,10:20:30,,Failed,,received data storage failure. 18/5/01,10:20:30,,,,"CTS foot 46.00, vme p2 41.84, eu 50.17, cpu 48,77, exc 55.04" 18/5/01,10:23:57,,Power off 231,, 18/5/01,,,,, 18/5/01,10:35:30,CK,Power on 232,,"Added analyzer signals A13, A14, A20, A30, A29, A28, B28, C11, A16, A9" 18/5/01,10:37:00,CK,cmd,,"Sent, Heater Control cmd. Received ACK and NACK" 18/5/01,10:38:02,CK,cmd,,Sent Internal Calibration cmd. Received ACK and NACK 18/5/01,10:39:00,CK,Failed,, 18/5/01,10:41:51,CK,Power off 232,, 18/5/01,10:42:12,CK,Power on 233,, 18/5/01,10:48:05,CK,Power off 233,, 18/5/01,10:48:50,CK,,,Stopping time update interrupt 18/5/01,10:49:10,CK,Power on 234,, 18/5/01,10:51:41,,Failed,, 18/5/01,10:58:20,,Power off 234,, 18/5/01,11:05:50,,Power on 235,, 18/5/01,11:23:00,MAF,,,turn off ROSIS 18/5/01,11:26:00,MAF,,,ROSIS power off 18/5/01,11:28:00,MAF,,,ROSIS power on 18/5/01,,MAF,Failed,, 18/5/01,,,,,"With ROSIS software shut down, but ROSIS power on, receiving interrupts for time sync. When completely shut down ROSIS power, time syncs stop." 18/5/01,11:49:42,CK,Power off 235,, 18/5/01,, ,,, 18/5/01,13:11:00,,,,Demated CPU P1 saver to add wire. 18/5/01,,,,,DO NOT POWER UP SYSTEM UNTIL REINSTALLED. 18/5/01,14:13:00,,,,Restarted ROSIS 18/5/01,14:42:00,,Power on 236,, 18/5/01,,,,,Logic Analyzer added wire to connector saver P1 at C10 18/5/01,,,,,Reinstall P1. 18/5/01,,,,,Uploading software to RAM vxWorks_051801_intdiag_2.bin 18/5/01,14:55:00,,Failed,,DSI failure 18/5/01,14:55:10,,Failed,,DSI failure 18/5/01,,,,,"CTS ft 46.87, VME p2 44.45, EU 50.86, CPU 50.13, exc 55.03" 18/5/01,14:58:00,,Failed,,3rd failure 18/5/01,14:59:45,,,,CMD software reset. 18/5/01,15:00:50,,Power off 236,, 18/5/01,15:01:25,,Power on 237,,Loading double Eprom. 18/5/01,,,Failed,, 18/5/01,15:04:10,,Power off 237,, 18/5/01,15:04:35,,Power on 238,, 18/5/01,15:06:00,,Failed,,First failure 18/5/01,15:06:20,,,,"Second, third failure." 18/5/01,15:19:18,,Power off 238,, 18/5/01,15:20:42,,Power on 239,,System failed 18/5/01,15:23:02,,Power off 239,, 18/5/01,15:40:00,,,,Added 1K pullup from A32 on VME P1 to IACK_N on logic analyzer 18/5/01,15:41:45,,Power on 240,, 18/5/01,15:44:00,,Failed,, 18/5/01,15:45:15,,Power off 240,, 18/5/01,,,,,Adding 1K pullup did not change behavior of failure ,,,,,Turned off SIS to prevent time sync interrupts from getting to instrument 18/5/01,15:49:00,,Power on 241,, 18/5/01,15:51:00,,Failed,, 18/5/01,15:52:00,,Power off 241,, 18/5/01,,,,,Taking out 1K pullup 18/5/01,16:18:10,,Power on 242,, 18/5/01,,,,,Running with analyzer looking at longer time scale to capture beginning of failure problem 18/5/01,16:20:00,,Failed,, 18/5/01,16:21:38,,Power off 242,, ,,,,,Captured longer time scales on logic analyzer 18/5/01,16:34:35,,Power on 243,,Hooked up oscilloscope to see if can catch analog picture of failure 18/5/01,16:37:00,,,,Failed 18/5/01,16:38:38,,power off 243,, 18/5/01,16:44:13,,Power on 244,, 18/5/01,,,,,Failed - captured part of trace on oscilloscope 18/5/01,16:48:05,,Power off 244,, 18/5/01,,,Configuration,,"Removed RS6000 SN 37, replaced with RS6000 SN14 (spare)" ,,,,,Remounted on thermal vacuum plates ,,,,, 21/5/01,8:30:00,,,,Torqued down instrument Monday,9:15:00,MAF,,,closed chamber door ,9:43:00,,set plate temp,,Set large heat exchanger to 25C; set small heat exchanger to 25C ,10:07:00,,temp readings,"MIRO TC, Facility TC, eng","Ob bench 22.3, 24.7" ,,,,,"SBEU INF 21.94, 22.2" ,,,,,"EU Inf 23.89, 22.9" ,,,,,"USO Inf 22.57, 23.3" ,,,,,"small plate 24.8, 25.5" ,,,,,"large plate 25.2, 23.8" ,10:13:45,,power on 245,,SIS V=28.4 at I=1.16 ,,,,loading eeprom,vxWorks_052101_ee.bin ,10:28:00,,,,"SIS V=28.4 at I=.67, +5VSBEU CUR=0.124A" ,10:31:04,,cmd,,"IFP Power =3, +5VSBEU_CUR=0.124A" ,10:32:06,,cmd,,"IFP Power =5, +5VSBEU_CUR=0.124A" ,10:33:48,,cmd,,"change mode to CTS/dual, +5VSBEU_CUR=0.292A, to 1.327A" ,10:35:32,,cmd,,"change mode to eng, +5VSBEU_CUR=0.141A" ,10:38:48,,cmd,,"USO off, SIS V=28.4, I=0.67A" ,10:42:40,,power off 245,, ,10:48:13,,power on 246,loading eeprom,vxWorks_052101_02_ee.bin ,10:52:00,,temp readings,"MIRO TC, Facility TC, eng","Ob bench 23.69, 25.3" ,,,,,"SBEU INF 24.1, 25.0" ,,,,,"EU Inf 24.8, 24.8" ,,,,,"USO Inf 24.1, 25.0" ,,,,,"small plate 24.7, 25.5" ,,,,,"large plate 24.7, 25.2" ,11:00:00,MAF,begin LFT,, ,11:40:32,,set plate temp,,Set large heat exchangerfrom 25C to 23C; set small heat exchanger from 25C to 23C ,13:18:40,MAF,finished LFT,, ,,,power off 246,, ,13:20:00,,pump down,,pumping down ,14:26:00,,set plate temp,,"Set large heat exchanger to 22C; set small heat exchanger to 22C, cool cold load with LN2" ,14:32:00,MAF,temp readings,"MIRO TC, Facility TC, eng","Ob bench 22.88, 23.4" ,,,,,"SBEU INF 25.27, 26.4" ,,,,,"EU Inf 24.6, 25.8" ,,,,,"USO Inf 25.5, 26.8" ,,,,,"small plate 21.89, 22.1" ,,,,,"large plate 22.07, 26.0" ,,,,,pressure= 1.2e-5 ,14:35:00,,begin LFT,, ,14:36:20,,power on 247,, ,16:30:00,,finish LFT,, ,16:30:27,,cmd,,mode change to dual continuum ,16:31:00,,start cal mir,,cal mirror verification ,18:35:00,,end cal mirror,, ,,,,,Get initial setting for calibration ,18:47:31,,cmd,,Turn USO Off ,START TIME,END TIME,COMMAND,,NOTES: ,,,,,CYCLE nUMBER 1 ,,,,,CYCLE NUMBER 1. Already at temperature. ,19:08:00,,,,REQUEST LARGE PLATE TEMPERATURE= 22 C ,,,,,REQUEST SMALL OB PLATE TEMPERATURE= 22 C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= 21.53 ;TSMALL = 21.57 ; TCOLD = -183.3" ,19:09:17,0:00:00,"POWER ON = ""LAST POWER OFF +1""/ SKIP THIS CMD IF POWER IS ALREADY ON",,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= 28.3 ;AMP = 1.65" ,19:09:17,0:30:00,USO WARMUP/,,ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING ,19:39:17,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=5(50C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,20:09:18,0:15:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM UP; ALLOW 15 MINUTES" ,20:24:10,0:00:00,mm LNA OFF/,, ,20:24:22,0:05:00,smm LNA OFF/,, ,20:29:22,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,20:34:15,0:00:00,mm LNA ON/,, ,20:34:24,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.82 ;TSMALL = 21.63 ; TCOLD = -167.9" ,21:04:24,0:35:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,21:39:24,0:35:00,CTS -DUAL CONTINUUM/2,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.70 ;TSMALL = 21.40 ; TCOLD = -182.9" ,22:14:24,0:35:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,22:49:24,0:35:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.69 ;TSMALL = 21.53 ; TCOLD = -181.9" ,23:24:24,0:35:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,23:59:25,0:10:00,CTS INTERNAL CALIBRATION,, 22/5/01,0:09:26,0:35:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.85 ;TSMALL =21.59 ; TCOLD =-167.5" ,0:44:26,0:35:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,1:22:15,0:35:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=22.04 ;TSMALL = 22.02 ; TCOLD =-185.1" ,1:57:15,0:35:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,2:32:15,0:35:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=22.31 ;TSMALL =22.39 ; TCOLD =-172.4" 22/5/01,3:07:15,0:00:00,mm LNA OFF/,, ,3:07:31,0:15:00,smm LNA OFF/,, ,3:22:31,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,3:32:30,0:00:00,mm LNA ON/,, 22/5/01,3:32:55,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 22.41 ;TSMALL = 22.24 ; TCOLD =-183.7" ,4:02:55,0:35:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,4:37:55,0:35:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=6(60C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,5:12:55,0:35:00,CTS -DUAL CONTINUUM/,, ,5:47:54,0:35:00,CTS -DUAL CONTINUUM/,, ,6:22:56,0:35:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=22.59 ;TSMALL =22.47 ; TCOLD =-185.1" ,6:57:55,0:35:00,DUAL-CONTINUUM,, ,7:32:04,0:35:00,DUAL-CONTINUUM,, 22/5/01,8:10:02,0:35:00,DUAL-CONTINUUM,sg start,"ALLOW 30 MINUTES FOR BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=22.53 ;TSMALL =22.53 ; TCOLD =-171." ,8:45:26,0:00,mm LNA OFF/,, ,8:45:40,0:10,smm LNA OFF/,,Current = 1.26 amps; V=28.3 ,8:54:17,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,9:00:06,0:00,mm LNA ON/,, ,9:00:23,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=22.116 ;TSMALL =22.237 ; TCOLD =-176.5/Power 1.43 amps" 22/5/01,9:30:59,0:10,Engineering Mode,,V=28.4; I=0.92 amps ,,,,,Go to Cycle 2/CHANGE TEMPERATURE LEVEL ,,,,, ,,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,,,,, ,,,,, ,,,,,CYCLE NUMBER 2 ,,,,, ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE 22/5/01,9:36:00,,"move Temp up +D605",,CYCLE NUMBER 2/instrument in engineering mode ,,,(9:36/27),,REQUEST LARGE PLATE TEMPERATURE= 52 C ,,,(10:00/32)(10:15/37),,REQUEST SMALL OB PLATE TEMPERATURE= 37 C ,,,10:30/42LP)(10:45/47LP),,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,,(11:00/52LP),,"AFTER THREE PLATES HAVE STABILIZED, RECORD Time, and TEMPERATURES -PROCEED TLARGE=51.3 ;TSMALL = 36.8 ; TCOLD = -185.8" 22/5/01,11:00:00,0:00:00, POWER IS ALREADY ON,,p=7E-7 TORR ,11:04:30,0:30:00,USO WARMUP/,,ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING ,11:05:58,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=7(70C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,11:15:43,0:35:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM UP; allow 40 MINUTES" ,11:53:03,0:00:00,mm LNA OFF/,,MMLNA = 39.98/SMMLNA=40.9 ,11:53:16,0:05:00,smm LNA OFF/,,V=28.3/ 2.3 AMPS ,11:58:45,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,12:03:13,0:00:00,mm LNA ON/,, ,12:03:25,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=51.74 ;TSMALL =36.95 ; TCOLD =-167.8" ,12:34:10,0:36:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS 22/5/01,13:10:10,0:36:00,CTS -DUAL CONTINUUM/2,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=52.3 ;TSMALL =37.6 ; TCOLD =-170" ,13:12:28,0:36:00,,,CMD TO CTS-DUAL CONTINUUM/2.5 ,13:49:02,0:36:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS 22/5/01,14:26:57,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=51.45 ;TSMALL = 36.42 ; TCOLD =-183" ,15:08:34,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,15:45:51,0:10:00,CTS INTERNAL CALIBRATION,,15:15:52 calibration heater on ,15:49:38,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= ;TSMALL = ; TCOLD =" ,16:29:38,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS (M. Hofstadter on duty) ,17:09:39,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 51.17 ;TSMALL = 36.37 ; TCOLD = -159.0" ,17:49:39,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS 22/5/01,18:29:39,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 50.93;TSMALL = 36.20; TCOLD = -178.5" ,19:10:22,0:00:00,mm LNA OFF/,, ,19:10:30,0:15:00,smm LNA OFF/,, ,19:25:30,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,19:35:33,0:00:00,mm LNA ON/,, 22/5/01,19:35:43,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 51.24;TSMALL = 36.11 ; TCOLD = -178.4" ,20:05:54,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,20:45:54,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=7(70C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,21:25:54,0:40:00,CTS -DUAL CONTINUUM/,, ,22:05:55,0:40:00,CTS -DUAL CONTINUUM/,, ,22:45:56,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 50.75 ;TSMALL = 36.05; TCOLD = -173.7" 22/5/01,23:25:56,0:40:00,DUAL-CONTINUUM,, 23/5/01,0:06:09,0:40:00,DUAL-CONTINUUM,, ,0:46:09,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=51.26 ;TSMALL = 36.19 ; TCOLD =-183.9" ,1:26:08,0:00,mm LNA OFF/,, ,1:26:30,0:10,smm LNA OFF/,, ,1:36:31,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,1:46:18,0:00,mm LNA ON/,, 23/5/01,1:46:51,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=50.98 ;TSMALL =36.17 ; TCOLD = -161.2" ,2:18:00,,Engineering mode,,Wait for calibration/ then go to engineering mode ,,,,,Go to cycle 3/Change temperature ,,,,, ,,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,,,,, ,,,,, ,,,,, ,,,,, ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,2:24:00,,,,CYCLE NUMBER 3 ,,,2:40:00/48.5C 2:50:00/42.2C,,REQUEST LARGE PLATE TEMPERATURE= 42 C ,,,,,REQUEST SMALL OB PLATE TEMPERATURE= 37 C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,2:59:00,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= 41.70 ;TSMALL = 36.35 ; TCOLD = -165.4" 23/5/01,2:59:00,0:00:00, POWER IS ALREADY ON,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE=28.4 V ;AMP = 0.87A" ,3:03:15,0:00:00,Warm load heater on,, ,3:04:20,0:30:00,USO ON FOR WARMUP/,USO heater is already ON,ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING 23/5/01,3:07:00,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=7(70C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,3:35:00,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,4:15:00,0:00:00,mm LNA OFF/,, ,4:15:17,0:05:00,smm LNA OFF/,, ,4:20:17,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,4:25:17,0:00:00,mm LNA ON/,, ,4:25:39,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 41.71 ;TSMALL =37.04 ; TCOLD = -174.3" 23/5/01,4:55:39,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,5:35:40,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= 41.59 ;TSMALL = 36.78 ; TCOLD = -170.5" ,6:15:40,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,6:55:40,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 41.61 ;TSMALL = 36.72 ; TCOLD = -178.5" ,7:35:40,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,8:15:51,0:10:00,CTS INTERNAL CALIBRATION,, 23/5/01,8:28:39,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 43.5 ;TSMALL = 37.6 ; TCOLD = -184.9" ,9:05:21,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,9:42:26,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 43.5 ;TSMALL = 37.7 ; TCOLD = -163.6" ,10:19:20,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,10:59:58,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 43.5 ;TSMALL = 37.9 ; TCOLD = -180.0" ,11:34:50,,,,automatic calibration started ,11:38:35,0:00:00,mm LNA OFF/,, ,11:38:48,0:15:00,smm LNA OFF/,,V=28.3 @2.31A ,11:53:50,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,11:58:23,0:00:00,mm LNA ON/,, ,11:58:37,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 43.4 ;TSMALL = 37.7 ; TCOLD = -174.9" ,12:33:25,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 23-May-01,13:13:20,0:40:00,"CTS HEATER CONTROL,HEATER = 0(HIGH), T=7(70C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,13:43:42,0:40:00,CTS -DUAL CONTINUUM/,, ,14:20:24,0:40:00,CTS -DUAL CONTINUUM/,, ,14:57:05,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 43.3 ;TSMALL = 37.7 ; TCOLD = -171.2" ,15:33:48,0:40:00,DUAL-CONTINUUM,, ,16:10:42,0:40:00,DUAL-CONTINUUM,, ,16:50:52,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=41.6 ;TSMALL =36.7 ; TCOLD =--162.7" ,17:31:44,0:00,mm LNA OFF/,, ,17:32:40,0:10,smm LNA OFF/,, ,17:42:05,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,17:47:00,0:00,mm LNA ON/,, ,17:47:00,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=40.82 ;TSMALL = 36.71 ; TCOLD =-162.9" ,18:18:25,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode ,,,,, ,,,,,Go to cycle 4 ,,,,,"REMEMBER TO change THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,,,,, 23-May-01,sg/tk,,,,CYCLE NUMBER 4 ,,,,,REQUEST LARGE PLATE TEMPERATURE= 32C ,18:21:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= 32 C ,18:21:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,,,,"small plate was lowered to 32 c in one step large plate was lowered in two steps (42->37->32)" ,18:51:00,,"large and small plate T should regulate to less than 1 deg C",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE=31.87 ;TSMALL =31.58 ; TCOLD =-175.9" ,18:52:00,0:00:00,,,"INSTRUMENT IS POWERED ON: IN ENGINEERING MODE ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= 28.4 ;AMP =0.89 " ,18:52:41,0:00:00,Warm load heater on,, ,18:54:19,0:00:00,USO WARMUP/,,"ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING IF USO HAS BEEN TURNED OFF; OTHERWISE ISSUE COMMAND AND CONTINUE" ,18:55:39,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=6(60C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:10:28,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES Turned CTS/dual mode on early because small plate was not regulating well/engineer suggested powering on instrume v=28.2; I = 2.46/raised temp set point to 34 deg" ,19:47:59,0:00:00,mm LNA OFF/,, ,19:48:34,0:05:00,smm LNA OFF/,, ,19:53:38,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,19:58:10,0:00:00,mm LNA ON/,, ,19:58:24,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=31.99 ;TSMALL = 32.13 ; TCOLD =-184.5" ,20:28:20,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS 23-May-01,21:12:00,0:30:00,RESET TSMALL,,"small plate temperature drifting;Paul reset regulator to 32 TLARGE=31.67; TSMALL=34.65" ,21:22:07,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= 31.707 ;TSMALL = 31.73 ; TCOLD =-175.8 pressure = 3.3 e -7 torr" ,22:00:05,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,22:37:42,0:40:00,CTS -DUAL CONTINUUM/4,,allow 40 MINUTES BETWEEN COMMANDS ,23:16:31,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS 24-May-01,23:56:20,0:10:00,CTS INTERNAL CALIBRATION,, ,0:06:20,0:40:00,CTS -DUAL CONTINUUM/6,,allow 40 MINUTES BETWEEN COMMANDS ,0:44:00,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,1:21:30,0:40:00,CTS -DUAL CONTINUUM/8,,allow 40 MINUTES BETWEEN COMMANDS ,2:00:00,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,2:38:00,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 31.70 ;TSMALL = 31.63 ; TCOLD = -173.5" ,3:14:28,,,,"NOTE: System crash apparently occurred at this time. Commands not accepted, Robert's screen not updating. " ,3:16:00,0:00:00,mm LNA OFF/,, ,3:16:15,0:15:00,smm LNA OFF/,, ,3:34:19,,mm LNA OFF/,,"No change in lna prt temperatures, so commands resent to turn off" ,3:34:46,,smm LNA OFF/,,etc. Time of 3:14:28 on GSE screen observed to not be updated. ,3:47:29,,software reset,,No effect seen ,3:56:00,,POWER OFF =247,,Pete commanding with Cindy on phone ,3:56:30,,POWER ON 248,, ,3:57:49,,cal heater on,, ,3:58:24,,"CTS WARMUP MODE,HEATER =0(HIGH),T=7(60C)/",, ,3:59:26,,CTS -DUAL CONTINUUM/,, ,4:02:38,,CTS WARMUP ,, ,4:17:12,0:10:00,CTS -DUAL CONTINUUM/,,restart cycle ,4:21:24,0:00:00,mm LNA OFF/,, ,4:21:36,0:15:00,smm LNA OFF/,, ,4:36:29,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,4:41:40,0:00:00,mm LNA ON/,, ,4:41:52,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 31.66 ;TSMALL = 31.79 ; TCOLD = -184.8" ,5:14:00,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,5:52:00,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=7(70C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,6:25:59,0:40:00,CTS -DUAL CONTINUUM/,, ,7:04:00,0:40:00,CTS -DUAL CONTINUUM/,,Start new temp logging file TVT 2 05/02/01 Data 05/24/101 07:23:26 ,7:42:00,0:40:00,CTS -DUAL CONTINUUM/,,allow 40 MINUTES BETWEEN COMMANDS ,8:19:01,0:40:00,DUAL-CONTINUUM,, ,8:55:51,0:40:00,DUAL-CONTINUUM,, ,9:33:03,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 34.5 ;TSMALL = 32.7 ; TCOLD = -185.7" ,10:08:25,,,,AUTO CALIBRATION STARTED ,10:13:02,0:00:00,mm LNA OFF/,, ,10:13:16,0:10:00,smm LNA OFF/,,v = 28.2 @ 2.35 amps ,10:23:03,0:10:00,DUAL-CONTINUUM,,FORCE CALIBRATION ,10:33:02,0:00:00,mm LNA ON/,, ,10:33:14,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING RECORD PLATE TEMPERATURES AND PROCEED TLARGE= 34.5 ;TSMALL = 32.5 ; TCOLD = -173.3 V=28.2 @ 2.52 AMPS" ,10:57:45,,,,AUTO CALIBRATION STARTED ,11:02:14,0:10:00,Engineering Mode,,wait for calibration/ then go to engineeringmode v = 28.4 @ 0.89 amps ,,,,, ,,,,,Go to cycle 5 ,,,,,"REMEMBER TO CHANGE THE TEMPERATURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,,,,, ,,,,, ,,,,, ,,,,, ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 5 24-May-01,11:02:20,,,,REQUEST LARGE PLATE TEMPERATURE= 27 C ,11:02:20,,,,REQUEST SMALL OB PLATE TEMPERATURE= 27 C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,11:17:45,,,,REQUEST LARGE PLATE TEMPERATURE= 22 C ,11:17:45,,,,REQUEST SMALL OB PLATE TEMPERATURE= 22 C ,,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= 25.3 ;TSMALL = 22.6 ; TCOLD = -168.4" ,11:30:00,0:00:00,,,Instrument is already powered on ,11:44:40,0:00:00,Warm load heater on (calibration htr),,v = 28.4 @ 1.24 amps ,11:44:40,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING (USO already on) OTHERWISE PROCEED AFTER ISSUING COMMAND" ,11:33:58,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=5(50C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,12:02:39,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,12:44:06,0:00:00,mm LNA OFF/,, ,12:44:19,0:05:00,smm LNA OFF/,,V = 28.2 @ 2.33 AMPS ,12:49:19,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,12:54:19,0:00:00,mm LNA ON/,, ,12:54:34,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 25.1 ;TSMALL = 22.6 ; TCOLD = -183.7 V = 28.2 @ 2.51 AMPS" ,13:26:39,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,14:03:21,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= 25.2 ;TSMALL = 22.6 ; TCOLD = -182.5" ,14:40:17,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,15:17:06,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 25.2 ;TSMALL = 22.6 ; TCOLD = -182.3" ,15:54:47,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,16:35:09,0:10:00,CTS INTERNAL CALIBRATION,, ,16:45:23,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.96 ;TSMALL =21,70 ; TCOLD =-182.9" ,17:25:15,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,18:06:00,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.94 ;TSMALL = 21.65 ; TCOLD = -176,0" ,18:46:00,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,19:29:00,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 21.83 ;TSMALL = 21.63 ; TCOLD =-180.8" ,20:09:50,0:00:00,mm LNA OFF/,, ,20:09:50,0:15:00,smm LNA OFF/,, ,20:24:00,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,20:34:00,0:00:00,mm LNA ON/,, ,20:34:23,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 21.57 ;TSMALL = 21.37 ; TCOLD =-183.6" ,21:04:00,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,21:44:00,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=6(60C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,22:24:50,0:40:00,CTS -DUAL CONTINUUM/,, ,23:04:30,0:40:00,CTS -DUAL CONTINUUM/,, ,23:44:00,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 21.65 ;TSMALL = 21.59 ; TCOLD =-182.0" 25-May-01,0:21:59,0:40:00,DUAL-CONTINUUM,, ,0:58:30,0:40:00,DUAL-CONTINUUM,, ,1:36:00,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 22.01 ;TSMALL = 21.99 ; TCOLD = -176.0" ,2:12:30,0:00,mm LNA OFF/,, ,2:12:46,0:10,smm LNA OFF/,, ,2:22:46,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,2:27:46,0:00,mm LNA ON/,, ,2:28:00,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE= 22.14 ;TSMALL = 21.99 ; TCOLD = -169.1" ,2:59:00,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode ,,,,,"SAVE TEMPERATURE DATA, START NEW FILE." ,,,,,Go to cycle 6 ,,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 6 25-May-01,2:59:00,,,,REQUEST LARGE PLATE TEMPERATURE= 17 C ,2:59:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= 17 C ,, ,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,3:13:00,,,,REQUEST LARGE PLATE TEMPERATURE= 12 C ,3:13:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= 12 C ,3:28:00,,,"large and small plates should regulate to less than 1 deg c","AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= 12.16 ;TSMALL = 11.93 ; TCOLD = -185.8" ,3:27:30,0:00:00,,,Instrument is already powered on ,3:26:09,0:00:00,Warm load heater on (calibration htr),,v = 28.4 @ 0.92 amps ,3:26:09,0:00:00,,,USO IS ON ,3:27:30,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),(T=40C)",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP Warmup mode appears to be set at 50C rather than 40 C- left unchanged SG This command was issued as CTS heater rather than CTS warmup; since CTS is off, the command was rejected by Robert's software; The heater control remained set to the previous value" ,3:57:30,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,4:36:00,0:00:00,mm LNA OFF/,, ,4:36:15,0:05:00,smm LNA OFF/,, ,4:41:15,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,4:46:15,0:00:00,mm LNA ON/,, ,4:46:30,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 12.22 ;TSMALL = 12.12 ; TCOLD = -180.5" ,5:19:00,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,5:57:00,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= 12.39 ;TSMALL = 12.32 ; TCOLD = -180.9" ,6:35:00,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,7:13:00,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 12.43 ;TSMALL = 12.46 ; TCOLD = -178.3" ,7:51:15,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,8:27:58,0:10:00,CTS INTERNAL CALIBRATION,, ,8:34:32,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 15.6 ;TSMALL = 12.5 ; TCOLD =-174.0 pressure 2.0e-7 torr" ,9:11:26,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS 25-May-01,9:47:45,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 15.7 ;TSMALL = 12.4 ; TCOLD =-171.4 pressure = 2e-7 torr" ,10:24:19,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,,,,,"SiS stopped at 10:45; Serial telemetry quit Ali restarted; successful on 3rd try Expect a gap in the data at 10:43:30 - probably 1 packet The SIS problem was introduced by Robert having a look at his system. The failure is fully understood and is not considered a problem." ,11:00:43,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 15.7 ;TSMALL =12.6 ; TCOLD =-178.7" ,11:40:43,0:00:00,mm LNA OFF/,, ,11:40:54,0:15:00,smm LNA OFF/,, ,11:47:41,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,11:55:33,0:00:00,mm LNA ON/,, ,11:55:44,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15.7 ;TSMALL = 12.5 ; TCOLD =-183.3" ,12:23:54,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,13:00:46,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=4(40C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" ,13:01:16,,CMD,"0(HIGH), T=4(40C)",CTS-WARM-UP ,13:02:00,,,,Noticed the FAILURE ON THE SUN COMPUTER ,13:23:05,,power off=248,,"Robert believes the failure was the result of issuing the CTS warmup command when the CTS is turned on" ,13:23:20,,power on=249,, ,13:24:24,0:40:00,CTS-dual cont,, ,13:25:07,,"Heater control 0(highpower)4(40C)",, ,13:30:49,,SMM gunn v auto ,control enable, ,13:31:14,0:40:00,CTS -DUAL CONTINUUM/,, ,14:10:34,0:40:00,CTS -DUAL CONTINUUM/,, 25-May-01,14:27:05,,calibration heater on,,noticed that warm load was not turned on(now warming up) ,14:51:02,0:40:00,CTS -DUAL CONTINUUM/,, ,15:37:46,0:39:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=15.7 ;TSMALL = 12.5 ; TCOLD =-179.4" ,16:14:07,0:00:00,CTS-DUAL-CONTINUUM,,should have entered dual continuum ,16:14:43,0:39:00,DUAL-CONTINUUM,,v=28.2 @ 1.42 amps ,16:52:29,0:39:00,DUAL-CONTINUUM,, ,17:27:10,,smm gunn voltage to 15,,from 5 (5027) ,17:28:30,,smm gunn voltage to 5,,from 15 (7658) ,17:29:24,0:39:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 14.6 ;TSMALL = 12.5 ; TCOLD =-185" ,18:04:06,0:00,mm LNA OFF/,, ,18:04:25,0:10,smm LNA OFF/,,"V=28.4 @ 1,26 amp" ,18:13:11,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,18:21:37,0:00,mm LNA ON/,, ,18:21:50,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE= 14.4 ;TSMALL = 12.6 ; TCOLD =-174.3 V=28.3, I =1.42" ,18:58:17,0:10,Engineering Mode,, ,18:59:55,,Power off = 249,,0 Volt and 0 current ,,,,,Shut down for beginning of memorial day weekend ,,,,,Start cycle 7 when we begin on Tueday morning 25-May-01,19:07:00,,"Turned off chamber pump Turned off large and small plates Turned off cold plate Turned off cold finger",,Closing down for Memorial day weekend ,,,,, 26-May-01,14:22:00,MAF/RN,Power on 250,,Loading RAM with test build vxWorks_052601_01_ee.bin ,,,,,in ENG ,14:42:30,,cmd ,,"PLL Reset ON, SIS V=28.4, I=0.66, when go to CTS should be reset" ,14:44:47,,cmd ,,"Submm Gunn Voltage = 10, SIS V=28.4, I=0.66-.67, when go to smm cont should be set" ,14:46:59,,cmd ,,"mode change to smm cont., smm cont level=8332, Robert says OK, Isis=0.93, smm Gunn Cur=132.318" ,14:50:41,,cmd ,,"Submm Gunn Voltage = 4, smm cont=7676, Isis=0.93, smm_Gunn_Cur=138.11" ,14:53:46,,cmd ,,"mode change to CTS/dual, PLL_Reset is still on, smm PLL Err=0.154, will also see if lock checking with attemp at relock executes" ,15:05:34,,cmd ,,"PLL Reset Off, smm_PLL_Err=0.384, not locked, why" ,15:09:50,,cmd ,,"set Submm volt to 4, smm_PLL_ERR voltage is 2.572,note this was necessary since the PLL Reset was on when the last calibration was done, and the auto lock was enabled, so the smm Gunn voltage got set to 7 instead of 4" ,15:14:22,,cmd ,,"CTS warm up cmd, program did not crash, was rejected" ,,,,,passed 5000 spectroscopic integrations without shutdown ,,,,,passed 6400 spectroscopic integrations without shutdown ,15:22:39,,cmd,,"PLL Reset ON, smm_PLL_ERR =1.484" ,15:24:41,,cmd,,"change mode to dual/continuum, PLL Reset set off (but save in gloabal coordinates so will get ON when go back into a CTS mode)" ,,,,,check to see if LO Freq switch gets cleared -yes ,,,,,check to see if FS's bit 11 is clear - yes ,15:28:42,,cmd,,"change mode to ENG, verify that SMM Gunn Voltage is set to 0 - yes" ,15:31:22,,power off 250,, ,15:32:00,,power on 251,,"had to restart BIST, Loading RAM with test build vxWorks_052601_01_ee.bin - saving to EEPROM" ,15:46:00,,,,"in ENG, SIS V=28.4, I=0.66" ,15:47:09,,cmd,,mode change to CTS/Dual ,16:10:16,,cmd,,"CTS Run time set to 13635, sm mult on" ,16:13:42,,cmd,,"CTS Run time set to 13400, sm mult on" ,16:17:32,,cmd,,change mode to ENG ,16:20:59,,power off 251,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, 29-May-01,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,startup after Memorial day weekend ,,,,,CYCLE NUMBER 7 ,7:50:00,sg,,,REQUEST LARGE PLATE TEMPERATURE= 2 C ,8:00:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= 2 C ,,,,,"Error message on computer----- ""ERR; Some files not created; look in log"" 05-26-2001, 17:00:00 Cannot open loging file e:\testteam\RWSData\2001_05_20\ RWSEGSELog - 20010526 - 170000.txt 05-26-2001, 17:00:00 Cannot open TLM file E:\testteam\RWSData \2001_05_26\ TLMdata-20010526 - 170000. bin Then next two lines say these files are created." ,,,,, ,8:05:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,10:18:00,DN,EGSE S/W,Upgrade,"SciXface program v4.6a: debugging CTS packets, output of CTS packet index. Also possible fix to CTS PLL Data problem when smoothing is other than 1." ,10:20:00,DN,EGSE Maintanance,Archive of miro-gse1,Used Winzip program to compress folders e:\testteam\RWSData and e:\testteam\TLMData and record to CD-R. Two hours? ,10:24:00,DN,ROSIS,Shutdown,"Power supply is turned off from back of rack. ROSIS commanded to local mode, TM block polling, serial polling, and RTU shutdown and logging shut down." 29/5/01,11:23:00,CK,POWER ON = 252,, ,11:34:00,RN,,PLL Lock Test,Loading vxWorks_052901_plltest.bin into RAM. ,11:53:00,RN,Command,,CTS / Dual Continuum Mode ,12:01:00,DN,,,28.3V @ 2.8A ,12:13:23,CK,Power OFF = 252,, ,12:16:03,CK,Power ON = 253,PLL Lock Test,Loading vxWorks_052901_plltest02.bin into RAM. ,12:20:00,DN,ROSIS,Failure,System watchdog failed. All TLM gathering quit. 28.3V @ 0.9A ,12:23:00,DN,ROSIS,Failure,System BIST test failed in local mode. ,12:45:49,SG,Cts-dual continuum,,Large plate=2.316; Small plate = 1.92; Tcold = -185.4 C ,12:49:00,0:00:00,,," VOLTAGE= 28.2 ;AMP = 2.81: p=4e-7 torr" ,,,,, ,13:42:00,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE=2.31 ;TSMALL =1.97 ; TCOLD =-168.1" ,13:38:42,0:00:00,Warm load heater on,, ,13:40:14,0:30:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" 29/5/01,13:42:39,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=3(30C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,14:12:04,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,14:52:00,0:00:00,mm LNA OFF/,, ,14:52:14,0:05:00,smm LNA OFF/,, ,14:57:02,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,15:02:01,0:00:00,mm LNA ON/,, ,15:02:15,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=6.5 ;TSMALL = 2.2 ; TCOLD =-184.0 ; P=3.4E-7 TORR" ,,,,, ,15:15:00,DN,EGSE,,COMPLETED ARCHIVAL OF MIRO-GSE1 AND MIRO-GSE2 DATA. ,15:16:00,DN,ROSIS,,STARTED TRANSFERRAL (FTP) OF ROSIS ARCHIVES TO MIRO-GSE2 ,,,,, ,15:32:06,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS 29/5/01,16:12:20,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE=2.24 ;TSMALL =1.65 ; TCOLD =-184.3" ,16:52:21,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,17:32:24,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=2.26 ;TSMALL = 1.90 ; TCOLD =-173." ,18:12:20,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,18:52:26,0:10:00,CTS INTERNAL CALIBRATION,, ,19:02:29,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=2.11 ;TSMALL =1.70 ; TCOLD =-180.4" ,19:42:24,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,20:22:23,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=2.06 ;TSMALL =1.67 ; TCOLD =-184.8" ,21:02:21,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS ,21:42:22,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=1.82 ;TSMALL =1.46 ; TCOLD =-183.4" ,22:22:22,0:00:00,mm LNA OFF/,, ,22:22:34,0:15:00,smm LNA OFF/,, ,22:37:44,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,22:47:44,0:00:00,mm LNA ON/,, ,22:47:54,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=2.12 ;TSMALL =1.76 ; TCOLD =-175.4" ,23:17:54,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,23:57:54,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=4(40C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" 30/5/01,0:38:50,0:40:00,CTS -DUAL CONTINUUM/,, ,,CRB/YUKI,,,crb was LATE ,1:18:42,0:40:00,CTS -DUAL CONTINUUM/,, ,1:58:30,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=2.069 ;TSMALL =1.798 ; TCOLD =-185.4" ,2:38:38,0:40:00,DUAL-CONTINUUM,, ,3:19:04,0:40:00,DUAL-CONTINUUM,, ,3:59:19,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=2.255 ;TSMALL =2.052 ; TCOLD =-174.8" ,4:39:14,0:00,mm LNA OFF/,,Will wait 1 minute to see if mm lna off gets into submm cont data ,4:40:15,0:10,smm LNA OFF/,, ,4:50:18,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,5:00:21,0:00,mm LNA ON/,, ,5:01:22,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=2.285 ;TSMALL =2.095 ; TCOLD =-184.3" ,5:31:27,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode ,,,,, ,,,,,Go to cycle 8 ,,,,,"REMEMBERing TO DECREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,,,,, ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 8 ,,,,,REQUEST LARGE PLATE TEMPERATURE= -8 C ,,,,,REQUEST SMALL OB PLATE TEMPERATURE= -8 C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE=-7.504 ;TSMALL =-7.971 ; TCOLD =-182.5" ,6:09:23,0:00:00,"POWER ON = ""LAST POWER OFF +1""/ SKIP THIS CMD IF POWER IS ALREADY ON",,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE=28.4 ;AMP =0.94 " ,6:11:16,0:00:00,Warm load heater on,,Issued calibration heater on command ,6:13:33,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,,,,,We (crb and Yuki) assume that USO warmup and cts warmup could proceed concurrently ,6:16:07,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,6:45:58,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,7:25:46,0:05:00,smm LNA OFF/,,Try this first to see if it gets into mm data ,7:26:45,0:00:00,mm LNA OFF/,, ,7:25:46,0:05:00,smm LNA OFF/,,Try this first to see if it gets into mm data ,7:31:58,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,7:38:46,0:00:00,mm LNA ON/,, ,7:37:56,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=-7.62 ;TSMALL =-8.007 ; TCOLD =-182.7" ,8:10:47,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,,CK,,,Noticed that interface temperatures were not at -5 as planned. Decision made by S. Gulkis to lower plate temperatures to achieve appropriate interface temperature and to continue test. ,,CK,,,Auto cal happened just as plate temperatures were changed 30/5/01,8:45:00,CK,,,Change large and small plate temperature to achieve -5 degrees on the interface. Large plate to -12 degrees and small to -10 degrees. 30/5/01,9:05:00,CK,,,Change large temperature to achieve -5 degrees on the interface. Large plate to -14 degrees. 30/5/01,9:20:59,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= -8.0 ;TSMALL = -9.8 ; TCOLD = -183.4" 30/5/01,10:34:17,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS 30/5/01,11:10:44,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -8.9 ;TSMALL = -9.7 ; TCOLD = -183.9" 30/5/01,11:47:23,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS 30/5/01,12:35:53,0:10:00,CTS INTERNAL CALIBRATION,, 30/5/01,12:45:55,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -8.9 ;TSMALL = -9.7 ; TCOLD = -182.3" 30/5/01,13:22:15,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS 30/5/01,13:58:40,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -8.9 ;TSMALL = -9.7 ; TCOLD = -180.6" 30/5/01,14:36:18,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS 30/5/01,15:12:36,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= -9.0 ;TSMALL = -9.7 ; TCOLD = -184.5" 30/5/01,15:54:40,0:00:00,mm LNA OFF/,, 30/5/01,15:54:51,0:15:00,smm LNA OFF/,,V=28.3 at 2.34 amps 30/5/01,16:09:53,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 30/5/01,16:19:53,0:00:00,mm LNA ON/,, 30/5/01,16:20:25,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -9.0 ;TSMALL = -9.7 ; TCOLD = -184.2" 30/5/01,16:50:53,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION;p=1.5e-7/sg on 30/5/01,17:30:55,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=3(30C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" 30/5/01,18:05:45,0:40:00,CTS -DUAL CONTINUUM/,,p=1.5e-7 torr 30/5/01,18:44:44,0:40:00,CTS -DUAL CONTINUUM/,, 30/5/01,19:24:07,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=-13.356 ;TSMALL =-9.73 ; TCOLD =-181.8" 30/5/01,20:01:34,0:40:00,DUAL-CONTINUUM, ,EU Elec Inter temperature still changing after 40 min 30/5/01,20:36:53,0:40:00,DUAL-CONTINUUM,,levels off after 42 minutes 30/5/01,21:11:27,0:38:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -13.23 ;TSMALL =-9.506 ; TCOLD =-185.6" 30/5/01,21:46:18,0:00,mm LNA OFF/,,p=1.4e-7 torr 30/5/01,21:46:49,0:10,smm LNA OFF/,, 30/5/01,21:56:52,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION 30/5/01,22:00:50,0:00,mm LNA ON/,, 30/5/01,22:01:22,0:37,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=-13.245 ;TSMALL = -9.5 ; TCOLD =-183.1" 30/5/01,22:39:18,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode ,,,,, ,,,,,Go to cycle 9 ,,,,,"REMEMBER TO change THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 9 30/5/01,22:43:00,,,,"REQUEST LARGE PLATE TEMPERATURE= -22 C go in 5C steps every 15 minutes" ,22:43:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= -20 C ,22:43:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,23:06:00,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= -16.2 ;TSMALL = -19.7 ; TCOLD = -183" ,,0:00:00,POWER IS ALREADY ON,,"in engineering mode :RECORD VOLTAGE=28.4 ;AMP = 0.94" ,23:10:03,0:00:00,Warm load heater on,, ,23:10:47,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,23:11:44,0:10:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=1(10C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,23:26:42,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" 30/5/01,23:43:00,,,,"Chamber EU=-4.9, SBEU=-9.5 sensors seem inconsistant with Ali's temps EU=-16.5 SBEU=-17.1" 31/5/01,0:06:11,0:00:00,mm LNA OFF/,, ,0:06:43,0:05:00,smm LNA OFF/,, ,0:11:33,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,0:17:00,0:00:00,mm LNA ON/,, ,0:17:14,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -26.12 ;TSMALL = -19.63 ; TCOLD = -186.8" ,0:49:07,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,1:27:10,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= -26.25 ;TSMALL = -19.71 ; TCOLD = -183.4" ,2:05:03,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,2:43:02,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES (Tlrg & Tsml from MIRO sensors) TLARGE= -25.92 ;TSMALL = -19.43 ; TCOLD = -178.2" ,3:21:03,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,3:58:58,0:10:00,CTS INTERNAL CALIBRATION,, ,4:09:09,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -26.42 ;TSMALL = -19.47 ; TCOLD = -185.6" ,4:10:00,,,,"Errors noted on TM monitor, ""Major TM Error: Incorrect time stamp"" in red showing up frequently. Called Peg, indications are that data is coming through OK so no action taken. Quick look data appears complete up to 4:00:00, will check new file after 5:00:00." ,4:48:45,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS ,4:54:00,,,,No more TM Errors are seen ,5:01:00,,,,TM Errors seen again. Review of quick look files indicates that times on CTS files update erratically beginning just after the CTS INTERNAL CALIBRATION command was sent at 3:58:58. MM and SubMM files show good times through the 4:00 file. ,5:28:15,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -26.05 ;TSMALL = -19.38 ; TCOLD = -181.0 Note: Cal cycle not seen after 38 minutes, command sent anyway. TM errors stop after command." ,5:37:00,,,,TM errors reappear. ,6:06:06,0:40:00,CTS -DUAL CONTINUUM/9,,Second cal cycle missing again. Quick look data for past hour indicates that time is not updated for any CTS records except during the forced calibration cycle. Continuum looks ok except that the submm shows a large permanent level change at the beginning of the cal cycle around 5:29. ,6:44:06,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= ;TSMALL = ; TCOLD =" ,7:19:44,0:05:00,CTS Dual Continnum/11,,Force a Calibration ,7:24:11,0:00:00,mm LNA OFF/,, ,7:24:29,0:15:00,smm LNA OFF/,, ,7:39:17,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION TLARGE= -25.93 ;TSMALL = -19.88 ; TCOLD = -182.3 ,7:49:24,0:00:00,mm LNA ON/,, ,7:49:37,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -25.87 ;TSMALL = -19.37 ; TCOLD = -176.2" ,8:13:55,0:40:00,CTS -DUAL CONTINUUM/,,"THIS WILL FORCE A CALIBRATION PLLs not locked, haven't been since 04:00." ,8:15:44,,,,"Issued command to set SMM Gunn voltage to 6. Immediately locked, phase lock error now 2.227, had been >3." ,8:17:41,0:40:00,CTS -DUAL CONTINUUM/,,Reissue command to get a cal while in lock ,8:57:39,0:00:00,smm LNA OFF/,,"Note that smm command was sent first, so 15 min wait is after mm LNA off" ,8:57:50,0:15:00,mm LNA OFF/,,Redo LNA cycling procedure ,9:12:49,0:10:00,CTS -DUAL CONTINUUM/,,"THIS WILL FORCE A CALIBRATION TLARGE= -25.86 ;TSMALL = -19.46 ; TCOLD = -184.5 (Tlg & Tsm from MIRO sensors for this entire shift, 08:00 - 16:00)" ,9:22:28,0:00:00,mm LNA ON/,,"NOTE: MS Excel crash lost recorded data from 09:15 to 11:35. Times recovered from data files (may be offset by ~30 s), temperatures lost." ,9:22:41,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= ;TSMALL = ; TCOLD = " ,9:53:00,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,10:32:08,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,11:10:44,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,11:50:24,0:40:00,CTS -DUAL CONTINUUM/,,RECORD PLATE TEMPERATURES TLARGE= -25.53 ;TSMALL = -19.22 ; TCOLD = 183.5 ,12:28:50,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=2(20C)/",, ,13:06:29,0:40:00,CTS -DUAL CONTINUUM/,, ,13:44:27,0:40:00,CTS -DUAL CONTINUUM/,, ,14:32:23,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= -25.78 ;TSMALL = -19.33 ; TCOLD = -185.0" ,15:14:51,0:40:00,DUAL-CONTINUUM,,In engg mode for 2 min. ,15:53:59,0:40:00,DUAL-CONTINUUM,, ,16:33:44,0:38:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=-26.08 ;TSMALL = --19.68 ; TCOLD =-185.2" ,17:08:25,0:00,mm LNA OFF/,, ,17:08:55,0:10,smm LNA OFF/,, ,17:17:59,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,17:20:50,0:00,mm LNA ON/,, ,17:20:50,0:35,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=-26.21 ;TSMALL =-19.68 ; TCOLD =-181.5" 31/5/01,17:54:33,0:10,Engineering Mode,,"wait for calibration/ then go to engineeringmode,p=1.2e-7torr" ,,,,, ,,,,,Go to cycle 10 ,,,,,"REMEMBER TO Change THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,START TIME,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 10 ,17:58:00,,,,"REQUEST LARGE PLATE TEMPERATURE= -14 C 5C in 15 minutes" ,17:58:00,,,,REQUEST SMALL OB PLATE TEMPERATURE= -10 C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,0:00:00," POWER IS ALREADY ON",,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE=28.2 ;AMP = 2.74 ; p=1e-7 torr" ,18:25:55,0:00:00,Warm load heater on,, ,18:26:28,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,18:26:59,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,18:34:03,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" ,,,"large and small plates should regulate to less than 1 deg c",,"Raise temperature of large plate to -12 C(19:04) AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ;TSMALL = ; TCOLD =" ,19:49:25,0:00:00,mm LNA OFF/,, ,19:49:40,0:05:00,smm LNA OFF/,, ,19:55:18,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION ,20:00:33,0:00:00,mm LNA ON/,, ,20:00:51,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=-13.124 ;TSMALL = -9.45 ; TCOLD =-181.4" ,20:30:51,0:38:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS ,21:08:14,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= -12.7 ;TSMALL =-9.139 ; TCOLD =-179.9" 31/5/01,21:45:13,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS ,22:21:49,0:38:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -12.749 ;TSMALL =-9.59 ; TCOLD =-173.6 p=1.2e-7" ,22:58:45,0:38:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS ,23:36:16,0:10:00,CTS INTERNAL CALIBRATION,,lost lock ,23:41:23,,smm Gunn V to 6,,locked after command was sent ,23:45:17,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= ;TSMALL = ; TCOLD =" 1/6/01,0:23:07,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,1:01:05,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -13.18 ;TSMALL = -9.41 ; TCOLD = -182.6" 1/6/01,1:39:04,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,2:17:06,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= -13.28 ;TSMALL = -9.45 ; TCOLD = -178.5" 1/6/01,2:55:08,0:00:00,mm LNA OFF/,, 1/6/01,2:55:24,0:15:00,smm LNA OFF/,, 1/6/01,3:10:23,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 1/6/01,3:20:22,0:00:00,mm LNA ON/,, 1/6/01,3:20:34,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -13.34 ;TSMALL = -9.54 ; TCOLD = -174.1" 1/6/01,3:48:38,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 1/6/01,4:26:34,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=3(30C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" 1/6/01,5:04:18,0:40:00,CTS -DUAL CONTINUUM/,, 1/6/01,5:42:13,0:40:00,CTS -DUAL CONTINUUM/,, 1/6/01,6:20:04,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= -13.43 ;TSMALL = -9.62 ; TCOLD = -184.9" 1/6/01,6:58:04,0:40:00,DUAL-CONTINUUM,, 1/6/01,7:36:06,0:40:00,DUAL-CONTINUUM,, 1/6/01,8:15:03,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= -13.2 ;TSMALL = -9.5 ; TCOLD = -182.8" 1/6/01,,,,,the above temperatures were recorded at 8:35 1/6/01,8:54:11,0:00,mm LNA OFF/,, 1/6/01,8:54:24,0:10,smm LNA OFF/,, 1/6/01,9:05:35,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION 1/6/01,9:14:48,0:00,mm LNA ON/,, 1/6/01,9:14:59,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE= -13.18 ;TSMALL = -9.53 ; TCOLD = -181.7" 1/6/01,9:46:05,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode 1/6/01,9:48:10,,Power Off 253,, 1/6/01,10:09:29,,Power On 254,, 1/6/01,,RN,,Test Software,Loading RAM with vxWorks_060101_01_test.bin 1/6/01,10:25:10,MAF,Power Off 254,,"Got through vxWorks banner then locked up, no access to vxWorks" 1/6/01,10:29:00,CK,Power On 255,, 1/6/01,,,,,S/W loaded. Sun had intense disk activity which would explain why previous load did not work. 1/6/01,10:46:02,CK,Command,,CTS/Dual Continuum 1/6/01,10:50:59,CK,Command,,CTS Internal Calibration 1/6/01,11:15:57,LWK,Command,,CTS Internal Calibration 1/6/01,11:20:03,,Command,,CTS Internal Calibration 1/6/01,11:26:12,,Command,,CTS Internal Calibration 1/6/01,,,,, 1/6/01,,,,, 1/6/01,,,,,Go to cycle 11 1/6/01,,,,,"REMEMBER TO Change THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" 1/6/01,,,,, 1/6/01,,,,, 1/6/01,START TIME,INTERVAL,COMMAND,,NOTES: 1/6/01,,,,,SEE TEMPERATURE CYCLE TABLE 1/6/01,,,,,CYCLE NUMBER 11 1/6/01,,,,,REQUEST LARGE PLATE TEMPERATURE= 2 C 1/6/01,,,,,REQUEST SMALL OB PLATE TEMPERATURE= 2C 1/6/01,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD 1/6/01,11:33:00,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= 2.83 ;TSMALL = 2.28 ; TCOLD = -184.4" 1/6/01,11:33:00,0:00:00,"POWER ON = ""LAST POWER OFF +1""/ SKIP THIS CMD IF POWER IS ALREADY ON",,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= 28.2 ;AMP = 2.58" 1/6/01,11:33:28,0:00:00,Warm load heater on,, 1/6/01,11:33:28,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" 1/6/01,11:33:28,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=3(20C)/",,"not doneTHIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" 1/6/01,11:35:35,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" 1/6/01,,,,,"build new code, data stacked up so will lose it when we power down, but most of it is unlocked anyway, will start anew after new code" 1/6/01,11:44:55,,cmd,,change mode to ENG 1/6/01,11:53:15,,power off 255,, 1/6/01,11:53:20,,power on 256,,Loading RAM with vxWorks_060101_02_test.bin 1/6/01,12:08:16,,Warm load heater on,, 1/6/01,12:09:17,,CTS Warmup,,"Power=high, T=30" 1/6/01,12:10:40,0:40:00,CTS-Dual Continuum,, 1/6/01,12:15:00,,CTS Internal Cal,, 1/6/01,12:20:29,,CTS Internal Cal,, 1/6/01,12:24:35,,CTS Internal Cal,, 1/6/01,12:29:08,0:40:00,CTS-Dual Continuum,, 1/6/01,13:09:30,0:00:00,mm LNA OFF/,, 1/6/01,13:09:41,0:05:00,smm LNA OFF/,, 1/6/01,13:12:53,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 1/6/01,13:17:10,0:00:00,mm LNA ON/,, 1/6/01,13:17:18,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 2.687 ;TSMALL = 2.145 ; TCOLD =-177.3" 1/6/01,13:46:09,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,14:25:06,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE= ;TSMALL = ; TCOLD =" 1/6/01,15:03:22,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,15:47:45,0:40:00,CTS -DUAL CONTINUUM/5,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,15:48:17,,CTS failure,,"CTS failure, did not get an interrupt back, went into engineering mode" 1/6/01,15:57:10,,CTS -dual continuum,,getting interrupts back from CTS ,,crb/ap,,, 1/6/01,16:02:49,,cmd,,Smm Gunn Voltage = 5 1/6/01,16:04:40,,CTS-dual continuum,, 1/6/01,16:27:27,0:10:00,CTS INTERNAL CALIBRATION,, 1/6/01,16:37:15,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=6.3 ;TSMALL = 2.3 ; TCOLD =-177.2" 1/6/01,17:13:26,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=6.4 ;TSMALL =2.4 ; TCOLD =-181.7" 1/6/01,17:49:53,0:40:00,CTS -DUAL CONTINUUM/9,,allow 40 MINUTES BETWEEN COMMANDS 1/6/01,18:26:19,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=6.3 ;TSMALL =2.4 ; TCOLD =-184.9" 1/6/01,19:02:51,0:00:00,mm LNA OFF/,, 1/6/01,19:03:52,0:15:00,smm LNA OFF/,,V=28.2 AT 2.32A WITH BOTH LNA'S OFF 1/6/01,19:18:31,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 1/6/01,19:28:41,0:00:00,mm LNA ON/,, 1/6/01,19:29:44,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 6.3 ;TSMALL = 2.4 ; TCOLD =-182.3 V=28.2 at 2.51A" 1/6/01,19:54:49,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 1/6/01,20:31:12,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=4(30C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE- cts was already set high, T=4 but we sent the command anyway" 1/6/01,21:05:01,0:40:00,CTS -DUAL CONTINUUM/,, 1/6/01,21:41:25,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE= 6.4 ;TSMALL = 2.5 ; TCOLD =-182.7" 1/6/01,22:18:10,0:40:00,DUAL-CONTINUUM,,V=28.4 at 1.42A 1/6/01,22:52:50,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=5.5 ;TSMALL =2.5 ; TCOLD =-179.8" ,23:27:20,0:00,mm LNA OFF/,, ,23:27:38,0:10,smm LNA OFF/,,V=28.4 at 1.27A ,23:38:08,0:10,DUAL-CONTINUUM,,FORCE CALIBRATION ,23:48:34,0:00,mm LNA ON/,, ,23:48:50,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE=5.1 ;TSMALL = 2.5 ; TCOLD =-180.8" ,0:12:44,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode ,0:22:44,,,, ,,,,,Go to cycle 12 ,,,,,"REMEMBER TO change THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,0:23:00,INTERVAL,COMMAND,,NOTES: ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 12 ,,,,,REQUEST LARGE PLATE TEMPERATURE= 12 C ,,,,,REQUEST SMALL OB PLATE TEMPERATURE= 12C ,,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,,,"large and small plates should regulate to less than 1 deg c",,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ;TSMALL = ; TCOLD =" ,0:23:00,0:00:00,"POWER ON = ""LAST POWER OFF +1""/ SKIP THIS CMD IF POWER IS ALREADY ON",,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ;AMP = " ,0:23:00,0:00:00,Warm load heater on,, 2/6/01,0:23:00,0:00:00,USO WARMUP/,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" 2/6/01,0:24:40,0:30:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=4(40C)/",,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" 2/6/01,1:23:53,0:40:00,CTS -DUAL CONTINUUM/,,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY; allow 40 MINUTES" 2/6/01,,,,,"TLARGE=13.9, TSMALL=11.7, TCOLD=-169.2, VOLTAGE=28.2, AMP=2.5" 2/6/01,2:02:32,0:00:00,mm LNA OFF/,, 2/6/01,2:02:47,0:05:00,smm LNA OFF/,, 2/6/01,2:07:47,0:05:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 2/6/01,2:12:47,0:00:00,mm LNA ON/,, 2/6/01,2:13:00,0:30:00,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15.4 ;TSMALL =12.7 ; TCOLD =-184.3" 2/6/01,2:44:18,0:40:00,CTS -DUAL CONTINUUM/1,,allow 40 MINUTES BETWEEN COMMANDS 2/6/01,3:20:48,0:40:00,CTS -DUAL CONTINUUM/2,," RECORD PLATE TEMPERATURES TLARGE=15.7 ;TSMALL =12.3 ; TCOLD =-180.9" 2/6/01,3:57:14,0:40:00,CTS -DUAL CONTINUUM/3,,allow 40 MINUTES BETWEEN COMMANDS 2/6/01,4:33:51,0:40:00,CTS -DUAL CONTINUUM/4,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15.7 ;TSMALL =12.5 ; TCOLD =-168" 2/6/01,5:11:08,0:40:00,CTS -DUAL CONTINUUM/6,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15.8 ;TSMALL = 12.7 ; TCOLD =-179.4" 2/6/01,5:47:36,0:40:00,CTS -DUAL CONTINUUM/7,,allow 40 MINUTES BETWEEN COMMANDS 2/6/01,6:24:02,0:40:00,CTS -DUAL CONTINUUM/8,,"allow 40 MINUTES BETWEEN COMMANDS ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15.8 ;TSMALL =12.6 ; TCOLD =-184." 2/6/01,7:00:27,0:40:00,CTS -DUAL CONTINUUM/10,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=15.8 ;TSMALL =12.6 ; TCOLD =-185.4" 2/6/01,7:36:56,0:00:00,mm LNA OFF/,, 2/6/01,7:37:15,0:15:00,smm LNA OFF/,, 2/6/01,7:52:18,0:10:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 2/6/01,8:02:16,0:00:00,mm LNA ON/,, 2/6/01,8:02:28,0:30:00,smm LNA ON/,," ALLOW 30 MINUTES BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE=15:7 ;TSMALL = 12.5 ; TCOLD =-176.5" 2/6/01,8:33:06,0:40:00,CTS -DUAL CONTINUUM/,,THIS WILL FORCE A CALIBRATION 2/6/01,9:13:13,0:40:00,"CTS HEATER CONTROL,HEATER= 0(HIGH), T=5(50C)/",,"PARAMETERS DEPEND ON LARGE PLATE TEMPERATURE, SEE HEATER CONTROL TABLE" 2/6/01,9:53:22,0:40:00,CTS -DUAL CONTINUUM/,, 2/6/01,10:34:53,0:40:00,CTS -DUAL CONTINUUM/,,"allow 40 MINUTES BEFORE PROCEEDING RECORD PLATE TEMPERATURES TLARGE=15.9 ;TSMALL = 12.6 ; TCOLD =-184.8" 2/6/01,11:15:06,0:40:00,DUAL-CONTINUUM,, 2/6/01,11:55:56,0:40:00,DUAL-CONTINUUM,,"ALLOW 30 MINUTES FOR WARMUP BEFORE PROCEEDING; RECORD PLATE TEMPERATURES TLARGE= 14.9 ;TSMALL =12.7 ; TCOLD =-176.0" 2/6/01,12:37:00,0:00,mm LNA OFF/,, 2/6/01,12:38:03,0:10,smm LNA OFF/,,SMM power switch already in off position when called up command. Left us wondering if we had miscommanded something previously. 2/6/01,12:50:16,0:10,DUAL-CONTINUUM,, 2/6/01,13:00:23,0:00,mm LNA ON/,, 2/6/01,13:00:47,0:30,smm LNA ON/,,"ALLOW 30 MINUTES FOR WARMUP BE PROCEEDING RECORD PLATE TEMPERATURES TEMPERATURES AND PROCEED TLARGE= 14.5 ;TSMALL = 12.6 ; TCOLD = -184.0" 2/6/01,13:29:38,0:10,Engineering Mode,,wait for calibration/ then go to engineeringmode 2/6/01,~13:40,,,,Started warm-up procedure. 2/6/01,,,,, 2/6/01,14:21:00,bi/mh,Power off 256,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,,,,, ,do not use these - they have been updated,,,,NOTES: ,SAM's MASTER,,,, ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 4 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=6(60C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= 32C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= 32 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 5 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 5 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=5(50C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= 22C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= 22 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 6 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 6 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=4(40C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= 12C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= 12 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 7 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 7 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=3(30C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= 2C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= 2 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 8 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 8 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= -8C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= -8 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 9 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 8 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= -8C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= -8 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 9 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 8 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= -8C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= -8 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 9 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 9 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=1(10C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= -18C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= -18 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 9 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,, ,,,,,NOTES: ,START TIME,INTERVAL,COMMAND,,Test Ports in Nominal Configuration ,,,,,Noise Sources OFF ,,,,,Spectrum Analyzer on PLE Test Port (J381) ,,,,,SEE TEMPERATURE CYCLE TABLE ,,,,,CYCLE NUMBER 8 ,,,,, ,,,,,"INSTRUMENT MAY ALREADY BE POWERED ON: ENTER ""NEW POWER ON"" NUMBER:RECORD VOLTAGE= ### ;AMP = ###" ,19:30:00,0:00:00,POWER ON = (SKIP IF ALREADY ON),, ,19:30:00,0:00:00,Warm load heater on,,"If USO IS TURNED OFF, ALLOW 30 MINUTES WARMUP BEFORE PROCEEDING OTHERWISE PROCEED AFTER ISSUING COMMAND" ,19:30:00,0:00:00,USO WARMUP/,,"THIS COMMAND IS CYCLE DEPENDENT, HEATER IS ALWAYS 0(HIGH), T CHANGES WITH LARGE PLATE TEMPERATURE; SEE TABLE; ALLOW 30 MINUTES FOR WARMUP" ,19:30:00,0:00:00,"CTS WARMUP MODE,HEATER =0(HIGH),T=2(20C)/",,"SYSTEM WILL AUTOMATICALLY CALIBRATE; IFP WILL WARM/COOL SLOWLY..." ,19:30:00,0:40:00,CTS -DUAL CONTINUUM/,, ,20:10:00,,,,REQUEST LARGE PLATE TEMPERATURE= -8C ,20:10:00,0:00:00,,,REQUEST SMALL OB PLATE TEMPERATURE= -8 C ,20:10:00,,,,REQUEST COLD LOAD PLATE TEMPERATURE= COLD ,20:10:00,,,, ,20:10:00,,,,"Record Spectra as per ""4.6 LO lock and Frequency Switching Test"" as necessary during transition." ,20:10:00,,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,Filename: TV####.tdx ,20:10:00,0:00:00,,,"AFTER THREE PLATES HAVE STABILIZED, RECORD TEMPERATURES AND PROCEED TLARGE= ### ;TSMALL = ### ; TCOLD = ###" ,20:10:00,,"large and small plates should regulate to less than 1 deg c",, ,20:10:00,,,,"Test Ports as per ""4.1 Noise Figure of the IFP""" ,20:10:00,0:05:00,,,Record Trace B ,20:15:00,0:01:00,smm LNA OFF/,,Record Trace A; Filename: TV####.tdx ,20:16:00,0:01:00,smm LNA ON/,, ,20:17:00,,,,"Test Ports as per ""4.2 Noise Figure of the CTS""" ,20:17:00,0:05:00,,,"""hot"" configuration" ,20:22:00,0:05:00,CTS -DUAL CONTINUUM/1,,"""cold"" configuration; Filename: TV####.tdx" ,20:27:00,0:05:00,CTS -DUAL CONTINUUM/1,, ,20:32:00,,,,"Test Ports as per ""4.3 IF Frequency Sweep Test""" ,20:32:00,0:05:00,,,SigGen=5.753 GHz ,20:37:00,0:05:00,CTS -DUAL CONTINUUM/1,,SigGen=5.877 ,20:42:00,0:05:00,CTS -DUAL CONTINUUM/2,,SigGen=9.667 ,20:47:00,0:05:00,CTS -DUAL CONTINUUM/3,,SigGen=9.685 ,20:52:00,0:05:00,CTS -DUAL CONTINUUM/4,,SigGen=10.791 ,20:57:00,0:05:00,CTS -DUAL CONTINUUM/5,,SigGen=13.455 ,21:02:00,0:05:00,CTS -DUAL CONTINUUM/6,,SigGen=15.137 ,21:07:00,0:05:00,CTS -DUAL CONTINUUM/7,,SigGen=16.338 ,21:12:00,0:05:00,CTS -DUAL CONTINUUM/8,, ,21:17:00,,,,"Test Ports as per ""4.4 Linearity in CTS/Dual Mode""" ,21:17:00,0:05:00,,,Turn on Chopping Noise Sources ,21:22:00,0:01:00,,,nominal pads ,21:22:00,0:10:00,CTS -DUAL CONTINUUM/1,,+2 dB pads ,21:32:00,0:10:00,CTS -DUAL CONTINUUM/2,,-2 dB pads ,21:42:00,0:10:00,CTS -DUAL CONTINUUM/3,, ,21:52:00,,,,"Test Ports as per ""4.5 Linearity in Dual Continuum Mode""" ,21:52:00,0:05:00,,, ,21:57:00,0:05:00,DUAL-CONTINUUM/,,Noise Sources ON ,22:02:00,0:01:00,,,nominal pads ,22:03:00,0:15:00,DUAL-CONTINUUM/1,,+2 dB pads ,22:18:00,0:15:00,DUAL-CONTINUUM/2,,-2 dB pads ,22:33:00,0:15:00,DUAL-CONTINUUM/3,, ,22:48:00,,,,Noise Sources OFF ,22:48:00,0:01:00,,, ,22:49:00,,,,"Test Ports as per ""4.6 LO lock and Frequency Switching Test"" (Nominal)" ,22:49:00,0:05:00,CTS -DUAL CONTINUUM/,,Record Spectra per 4.6... ,22:54:00,,,,Filename: TV####.tdx ,22:54:00,0:03:00,,,Filename: TV####.tdx ,22:57:00,0:03:00,,,Filename: TV####.tdx ,23:00:00,0:03:00,,, ,23:03:00,,,,Go to cycle 9 ,23:03:00,,,,"REMEMBER TO INCREASE THE TEMPERTURE SETTINGS FOR CTS WARMUP MODE AND CTS HEAT MODE" ,23:03:00,,,,