PDS_VERSION_ID               = PDS3
LABEL_REVISION_NOTE  = "2016-12-12, SONC, version 1.0"

/* FILE CHARACTERISTIC DATA ELEMENTS */

RECORD_TYPE          = FIXED_LENGTH
FILE_RECORDS         = 255
RECORD_BYTES         = 6

/* DATA OBJECT POINTERS  */

^TABLE     = ("CONSERT_COMPRESSION_CODE.TAB",1 <BYTES>)

DATA_SET_ID         = "RO/RL-C-CONSERT-2-FSS-V1.0"
DATA_SET_NAME       = "ROSETTA-ORBITER/ROSETTA-LANDER 67P CONSERT 
                           2 FSS V1.0"
PRODUCT_ID          = "CONSERT_COMPRESSION_CODE"
PRODUCT_CREATION_TIME = 2016-12-12T11:00:55
MISSION_NAME         = "INTERNATIONAL ROSETTA MISSION"
MISSION_PHASE_NAME  = "FIRST SCIENCE SEQUENCE"
MISSION_ID           = ROSETTA
INSTRUMENT_HOST_NAME = "ROSETTA-LANDER"
INSTRUMENT_HOST_ID   = "RL"

PRODUCER_ID          = "SONC"
PRODUCER_FULL_NAME   = "SCIENCE OPERATIONS AND NAVIGATION CENTER"
PRODUCER_INSTITUTION_NAME = "CNES"

INSTRUMENT_ID        = CONSERT
INSTRUMENT_NAME      = "COMET NUCLEUS SOUNDING EXPERIMENT BY RADIOWAVE
                       TRANSMISSION"
INSTRUMENT_TYPE      = "RADAR"

/* DATA OBJECT DEFINITION  */


OBJECT                 = TABLE                                               
  INTERCHANGE_FORMAT   = ASCII                                               
  ROWS                 = 255                                   
  ROW_BYTES            = 6                                                   
  COLUMNS              = 1                                                   
                                                                             
  OBJECT              = COLUMN                                             
    NAME              = TX_COMPR_CODE                                   
    DATA_TYPE         = ASCII_REAL                                        
    START_BYTE        = 1                                                  
    BYTES             = 4                                                 
    DESCRIPTION       = "The Tx signal is a BPSK and the Rx signal
                         has to be compressed by this code (matched
                         filter). The table is the Tx BPSK sampled
                         at 10 MHz (one sample per symbol)."   
  END_OBJECT             = COLUMN                                            
                                                                             
END_OBJECT = TABLE                                                           
                                                                             
END