OBJECT = COLUMN NAME = CHECKSUM DATA_TYPE = ASCII_INTEGER START_BYTE = 2 BYTES = 11 DESCRIPTION = "Checksum of the keepalive data" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ORIGINATOR DATA_TYPE = ASCII_INTEGER START_BYTE = 14 BYTES = 11 DESCRIPTION = "Software version initializing the keepalive data: 0 = unknown 1 = version 5, i.e. PROM 2 = version higher 8 or higher 3 = version 5 updated from higher version" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = USEHV DATA_TYPE = ASCII_INTEGER START_BYTE = 26 BYTES = 11 DESCRIPTION = "flag, if it is 0x48564F4 = 1213615947, let's the high voltages to be turn on automatically in boot" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PARTITION DATA_TYPE = ASCII_INTEGER START_BYTE = 38 BYTES = 11 DESCRIPTION = "S/C memory partition used" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_PARTITION DATA_TYPE = ASCII_INTEGER START_BYTE = 50 BYTES = 11 DESCRIPTION = "S/C memory partition used, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_PROTECTION DATA_TYPE = ASCII_INTEGER START_BYTE = 62 BYTES = 11 DESCRIPTION = "Primary FDAQ board protection flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_AUTOCAL DATA_TYPE = ASCII_INTEGER START_BYTE = 74 BYTES = 11 DESCRIPTION = "Primary FDAQ board auto-calibration flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 86 BYTES = 11 DESCRIPTION = "Primary FDAQ board target flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_LO DATA_TYPE = ASCII_INTEGER START_BYTE = 98 BYTES = 11 DESCRIPTION = "Primary FDAQ board low sensitivity channel, 0 = low sensitivity 1, 1 = low sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_HI DATA_TYPE = ASCII_INTEGER START_BYTE = 110 BYTES = 11 DESCRIPTION = "Primary FDAQ board high sensitivity channel, 0 = high sensitivity 1, 1 = high sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_PULSE DATA_TYPE = ASCII_INTEGER START_BYTE = 122 BYTES = 11 DESCRIPTION = "Primary FDAQ pulse trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_INTEGRAL DATA_TYPE = ASCII_INTEGER START_BYTE = 134 BYTES = 11 DESCRIPTION = "Primary FDAQ integral trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_LO_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 146 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_LO_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 158 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_HI_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 170 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_HI_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 182 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_LO_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 194 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_LO_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 206 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_HI_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 218 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PRIM_HI_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 230 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_PROTECTION DATA_TYPE = ASCII_INTEGER START_BYTE = 242 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board protection flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_AUTOCAL DATA_TYPE = ASCII_INTEGER START_BYTE = 254 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board auto-calibration flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 266 BYTES = 11 DESCRIPTION = "Primary FDAQ board target flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_LO DATA_TYPE = ASCII_INTEGER START_BYTE = 278 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board low sensitivity channel, 0 = low sensitivity 1, 1 = low sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_HI DATA_TYPE = ASCII_INTEGER START_BYTE = 290 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board high sensitivity channel, 0 = high sensitivity 1, 1 = high sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_PULSE DATA_TYPE = ASCII_INTEGER START_BYTE = 302 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ pulse trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_INTEGRAL DATA_TYPE = ASCII_INTEGER START_BYTE = 314 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ integral trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_LO_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 326 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_LO_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 338 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_HI_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 350 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_HI_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 362 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_LO_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 374 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_LO_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 386 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_HI_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 398 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = AUX_HI_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 410 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ACTIVE_FDAQ DATA_TYPE = ASCII_INTEGER START_BYTE = 422 BYTES = 11 DESCRIPTION = "Active FDAQ board 0 = primary, 1 = auxiliary" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MM1 DATA_TYPE = ASCII_INTEGER START_BYTE = 434 BYTES = 11 DESCRIPTION = "MM-1 voltage setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = POLARITY DATA_TYPE = ASCII_INTEGER START_BYTE = 446 BYTES = 11 DESCRIPTION = "Ion polarity, 1 = positive, 2 = negative" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 458 BYTES = 11 DESCRIPTION = "Target size, 4 = small, 8 = large" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVS DATA_TYPE = ASCII_INTEGER START_BYTE = 470 BYTES = 11 DESCRIPTION = "High voltage setup, 0x00 = all off, 0x01 = converter on, 0x40 = RFB enabled, 0x80 = MM1-1 enabled, plus the OR-ed combinations of all bits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = EDF_TIMEOUT DATA_TYPE = ASCII_INTEGER START_BYTE = 482 BYTES = 11 DESCRIPTION = "Time-out to send housekeeping data in milliseconds" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMPRESS DATA_TYPE = ASCII_INTEGER START_BYTE = 494 BYTES = 11 DESCRIPTION = "Channel Compression, 0 = off, 1 = Rice, 2 = wavelet" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = CHANNELS DATA_TYPE = ASCII_INTEGER START_BYTE = 506 BYTES = 11 DESCRIPTION = "Channels included in the EDF, 0x01 = low straight channel, 0x02 = low delayed channel, 0x04 = high straight channel, 0x08 = high delayed channel, plus the OR-ed combinations of all bits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER DATA_TYPE = ASCII_INTEGER START_BYTE = 518 BYTES = 11 DESCRIPTION = "Encounter clock received from S/C" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_ENCOUNTER DATA_TYPE = ASCII_INTEGER START_BYTE = 530 BYTES = 11 DESCRIPTION = "Encounter clock received from S/C negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 542 BYTES = 203 ITEMS = 17 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Partition table limits expressed in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_FIRST_NEGATIVE DATA_TYPE = ASCII_INTEGER START_BYTE = 746 BYTES = 11 DESCRIPTION = "First time the instrument will switch the negative mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_NEGATIVE_TIME DATA_TYPE = ASCII_INTEGER START_BYTE = 758 BYTES = 11 DESCRIPTION = "Time to stay in negative mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ENCOUNTER_POSITIVE_TIME DATA_TYPE = ASCII_INTEGER START_BYTE = 770 BYTES = 11 DESCRIPTION = "Time to stay in positive mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SWITCH_ONS DATA_TYPE = ASCII_INTEGER START_BYTE = 782 BYTES = 11 DESCRIPTION = "Number of instrument switch ons" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_SWITCH_ONS DATA_TYPE = ASCII_INTEGER START_BYTE = 794 BYTES = 11 DESCRIPTION = "Number of instrument switch ons, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TOTAL_BYTES_TO_HEAP_SPACE DATA_TYPE = ASCII_INTEGER START_BYTE = 806 BYTES = 11 DESCRIPTION = "Total number of bytes sent to S/C encounter telemetry memory" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_TOTAL_BYTES_TO_HEAP_SPACE DATA_TYPE = ASCII_INTEGER START_BYTE = 818 BYTES = 11 DESCRIPTION = "Total number of bytes sent to S/C encounter telemetry memory, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = BYTES_TO_HEAP DATA_TYPE = ASCII_INTEGER START_BYTE = 830 BYTES = 11 DESCRIPTION = "Number of bytes in the S/C encounter telemetry memory, taking in to the account the partition limits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_BYTES_TO_HEAP DATA_TYPE = ASCII_INTEGER START_BYTE = 842 BYTES = 11 DESCRIPTION = "Number of bytes in the S/C encounter telemetry memory, taking in to the account the partition limits, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = LARGE_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 854 BYTES = 11 DESCRIPTION = "Limit to consider event large, used only in s/w version 5" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPECTRUM_HI_BIN_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 866 BYTES = 11 DESCRIPTION = "Limit to consider, that a real event is in high sensitivity channel" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPECTRUM_LO_BIN_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 878 BYTES = 11 DESCRIPTION = "Limit to consider, that a real event is in low sensitivity channel" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPECTRUM_HI_LO_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 890 BYTES = 11 DESCRIPTION = "High sensitivity level limit to consider, that the low sensitivity channel is to be included" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = POLARITY_INDEX DATA_TYPE = ASCII_INTEGER START_BYTE = 902 BYTES = 11 DESCRIPTION = "Ion polarity, 0 = positive, 1 = negative" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TRIGGER_PULSE_ADJUST DATA_TYPE = ASCII_INTEGER START_BYTE = 914 BYTES = 11 DESCRIPTION = "Value added to the pulse trigger DA after noise level calibration" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TRIGGER_INTEGRAL_ADJUST DATA_TYPE = ASCII_INTEGER START_BYTE = 926 BYTES = 11 DESCRIPTION = "Value added to the integral trigger DA after noise level calibration" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TARGET_TO_SMALL_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 938 BYTES = 11 DESCRIPTION = "Event rate in 1/s, when to switch to the small target" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TARGET_TO_LARGE_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 950 BYTES = 11 DESCRIPTION = "Event rate in 1/s, when to switch to the large target" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 962 BYTES = 11 DESCRIPTION = "Total number of events recorded" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINUS_EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 974 BYTES = 11 DESCRIPTION = "Total number of events recorded, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = WAVELET_FILTER_LENGTH DATA_TYPE = ASCII_INTEGER START_BYTE = 986 BYTES = 11 DESCRIPTION = "Wavelet filter length" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = WAVELET_LOPASS DATA_TYPE = ASCII_REAL START_BYTE = 998 BYTES = 47 ITEMS = 4 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Wavelet low pass filter parameters" FORMAT = "F11.5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = WAVELET_HIPASS DATA_TYPE = ASCII_REAL START_BYTE = 1046 BYTES = 47 ITEMS = 4 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Wavelet high pass filter parameters" FORMAT = "F11.5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEGATIVE_PULSE_FACTOR DATA_TYPE = ASCII_INTEGER START_BYTE = 1094 BYTES = 11 DESCRIPTION = "Factor to multiply the pulse trigger DA setup value for negative ion mode in units of 1/16" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEGATIVE_INTEGRAL_FACTOR DATA_TYPE = ASCII_INTEGER START_BYTE = 1106 BYTES = 11 DESCRIPTION = "Factor to multiply the negative trigger DA setup value for negative ion mode in units of 1/16" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPARE DATA_TYPE = ASCII_INTEGER START_BYTE = 1118 BYTES = 1163 ITEMS = 97 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Not currently used" FORMAT = "I11" END_OBJECT = COLUMN